Benedito de Moraes Purquerio

Benedito de Moraes Purquerio

Auto-generated profile, based on publicly available information

Benedito de Moraes Purquerio

University of São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2003 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
CTCecilia Pedroso Turssi
Cecilia Pedroso Turssi
BPBenedito de Moraes Purquerio
Benedito de Moraes Purquerio
MSMônica Campos Serra
Mônica Campos Serra

1 January 2017 in Journal of Applied Biomaterials & Functional Materials
Verified
Journal Article
Open access
CCClaudia C. Camilo
Claudia C. Camilo
CSCeley A.E. Silveira
Celey A.E. Silveira
RFRafael S. Faeda
Rafael S. Faeda
JRJoão M.D. de Almeida Rollo
João M.D. de Almeida Rollo
BPBenedito de Moraes Purquerio
Benedito de Moraes Purquerio
CFCarlos Alberto Fortulan
Carlos Alberto Fortulan
Background: Implants or implantable devices should integrate into the host tissue faster than fibrous capsule formation, in which the design of the interface is one of the biggest challenges. Generally, bioactive materials are not viable for load-bearing applications, so inert biomaterials are proposed. However, the surface must be modified through techniques such as coating with bioactive materials, roughness and sized pores. The aim of this research was to validate an approach for the evaluation of the tissue growth on implants of porous alumina coated with bioactive materials. Methods: Porous alumina implants were coated with 45S5 Bioglass® (BG) and hydroxyapatite (HA) and implanted in rat tibiae for a period of 28 days. Ex vivo resections were performed to analyze osseointegration, along with histological analysis, Scanning Electron Microscopy with Energy Dispersive X-Ray spectroscopy (SEM-EDX) line scanning, radiography and biomechanical testing. Results: Given that the process of implant integration needs with the bone tissue to be accelerated, it was then seen that BG acted to start the rapid integration, and HA acted to sustaining the process. Conclusions: Inert materials coated with bioglass and HA present a potential for application as bone substitutes, preferably with pores of diameters between 100 μm and 400 μm and, restrict for smaller than 100 μm, because it prevents pores without organized tissue formation or vacant. Designed as functional gradient material, stand out for applications in bone tissue under load, where, being the porous surface responsible for the osseointegration and the inner material to bear and to transmit the loads.

24 October 2011 in Disability and Rehabilitation: Assistive Technology
Verified
Journal Article
Closed access
PDF file
FMFausto Medola
Fausto Medola
CFCarlos Alberto Fortulan
Carlos Alberto Fortulan
BPBenedito de Moraes Purquerio
Benedito de Moraes Purquerio
VEValeria Meirelles Carril Elui
Valeria Meirelles Carril Elui
Report on the development of an ergonomic manual wheelchair pushrim and evaluate the user's perception of the quality of the device. Based on anthropometric features and ergonomic concepts, a new wheelchair pushrim was designed, and a prototype was manufactured in polyurethane, using the rapid prototyping technique and serial production of parts by molding. The prototype was tested by a sample of wheelchair users, who rated the perceived quality of the device after testing both the new and conventional pushrims in a wheelchair propulsion experimental protocol. The new ergonomic pushrim was found to be, in general, better than the conventional round tube pushrim. Specifically, experienced wheelchair users found the new wheelchair pushrim better in terms of easy and comfortable propulsion, braking and maneuvering of the wheelchair, and appearance. The new wheelchair pushrim provides a proper fit for the hands due to its ergonomic design and its polyurethane composition, making wheelchair propulsion easier and more comfortable than the conventional wheelchair pushrim. Assistive technology devices should be design based on ergonomic concepts that involve less effort and offer greater comfort for the user. [Box: see text].

23 June 2008 in Journal of Tribology
Verified
Journal Article
Closed access
PDF file
RNRodrigo Nicoletti
Rodrigo Nicoletti
ZSZilda Castro Silveira
Zilda Castro Silveira
BPBenedito M. Purquerio
Benedito M. Purquerio
Aerostatic porous bearings are becoming important elements in precision machines due to their inherent characteristics. The mathematical modeling of such bearings depends on the pressure-flow assumptions that are adopted for the flow in the porous medium. In this work, one proposes a nondimensional modified Reynolds equations based on the quadratic Forchheimer assumption. In this quadratic approach, the nondimensional parameter Φ strongly affects the bearing load capacity, by defining the nonlinearity level of the system. For values of Φ>10, the results obtained with the modified Reynolds equation with quadratic Forchheimer assumption tend to those obtained with the linear Darcy model, thus showing that this is a more robust and global approach of the problem, and can be used for both pressure-flow assumptions (linear and quadratic). The threshold between linear and quadratic assumptions is numerically investigated for a bronze sintered porous bearing, and the effects of bearing geometry are discussed. Numerical results show that Φ strongly affects the bearing loading capacity and stiffness coefficients.

29 March 2012 in Lubrication Science
Verified
Journal Article
Closed access
PDF file
RNRodrigo Nicoletti
Rodrigo Nicoletti
BPBenedito de Moraes Purquerio
Benedito de Moraes Purquerio
ZSZilda Castro Silveira
Zilda Castro Silveira

22 June 2016 in The International Journal of Advanced Manufacturing Technology
Verified
Journal Article
Closed access
PDF file
AMAlexandre Margarido
Alexandre Margarido
BPBenedito Moraes Purquerio
Benedito Moraes Purquerio
CFCesar R. Foschini
Cesar R. Foschini
CFCarlos Alberto Fortulan
Carlos Alberto Fortulan