Most biodegradation tests are conducted using single chemicals at high concentrations although these chemicals are present in the environment as mixtures at low concentrations. A partitioning based platform was recently developed for biodegradation testing of composed mixtures of hydrophobic chemicals at ng/L - µg/L concentrations. We used this platform to study the concentration and mixture effect on biodegradation kinetics. Biodegradation tests were conducted in 20 mL vials using environmental water samples as inoculum. Passive dosing was applied (1) to vary initial test concentrations of individual test compounds and (2) to vary the number of mixture components between 1 and 16. Automated SPME coupled to GC-MS was used to measure substrate depletion relative to abiotic controls. The number of mixture components had no or only limited effect on biodegradation half-times for three compounds, when tested at environmentally relevant concentrations. In contrast, longer lag phases and half-lives were observed for single compounds when tested at higher concentrations that approached aqueous solubility. The obtained results support that simultaneous testing of multiple chemicals at low concentrations can accelerate the generation of biodegradation kinetic data, which are more environmentally relevant compared to data from tests conducted with single chemicals at much higher concentrations.
Biodegradation is a dominant removal process for many organic pollutants, and biodegradation tests serve as tools for assessing their environmental fate within regulatory risk assessment. In simulation tests, the inoculum is not standardized, varying in microbial quantity and quality, thereby potentially impacting the observed biodegradation kinetics. In this study we investigated the effect of inoculum origin on the biodegradation kinetics of hydrocarbons for five inocula from surface waters varying in urbanization and thus expected pre-exposure to petroleum hydrocarbons. A new biodegradation method for testing mixtures of hydrophobic chemicals at trace concentrations was demonstrated: Aqueous solutions containing 9 hydrocarbons were generated by passive dosing and diluted with surface water resulting in test systems containing native microorganisms exposed to test substances at ng-μg/L levels. Automated Headspace Solid Phase Microextraction coupled to GC-MS was applied directly to these test systems to determine substrate depletion relative to abiotic controls. Lag phases were generally less than 8 days. First order rate constants were within one order of magnitude for each hydrocarbon in four of the five waters but lower in water from a rural lake. The sequence of degradation between the 9 hydrocarbons showed similar patterns in the five waters indicating the potential for using selected hydrocarbons for benchmarking between biodegradation tests. Degradation half-times were shorter than or within one order of magnitude of BioHCwin predictions for 8 of 9 hydrocarbons. These results showed that location choice is important for biodegradation kinetics and can provide a relevant input to aquatic exposure and fate models.
6 August 2021 in Environmental Science & Technology
Biodegradation kinetics data are keystone for evaluating the environmental persistence and risk of chemicals. Biodegradation kinetics depend highly on the prevailing temperature, which influences microbial community structures, metabolic rates, and chemical availability. There is a lack of high-quality comparative biodegradation kinetics data that are determined at different test temperatures but with the same microbial inoculum and chemical availability. The present study was designed to determine the effect of test temperature on the biodegradation kinetics of hydrocarbons while avoiding confounding factors. We used inocula from a Northern river (2.7 °C) and a Central European river (12.5 °C). Aqueous stock solutions containing 45 individual hydrocarbons were generated by passive dosing and added to river water containing the native microorganisms. Compound-specific biodegradation kinetics were then determined at 2.7, 12, and 20 °C based on substrate depletion. Main findings comprise the following: (1) Degradation half-times (DegT50) of 34 test chemicals were determined at different test temperatures and were largely consistent with the Arrhenius equation (activation energy, 65.4 kJ/mol). (2) Differences in biodegradation kinetics between tested isomers were rather limited. (3) The recent lowering of standard test temperature from 20 to 12 °C results typically in a doubling of DegT50 values and can lead to a stricter persistency assessment.
6 March 2020 in Environmental Science & Technology
This study assesses the impact of test concentration and potential mixture toxicity on biodegradation kinetics for individual constituents in two UVCB substances, diesel oil and lavender oil.