Cláudio Martins

Cláudio Martins

Auto-generated profile, based on publicly available information

Cláudio Martins

ISISE, Civil Engineering Department, University of Coimbra, Coimbra, Portugal

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Energy and Buildings
Verified
Journal Article
Closed access
NSNelson Alexandre da Cruz Soares
Nelson Alexandre da Cruz Soares
CMCláudio Martins
Cláudio Martins
MGMargarida Gonçalves
Margarida Gonçalves
Paulo SantosPaulo Santos
Paulo Santos
LSLuís Simões da Silva
Luís Simões da Silva
JCJosé J. Costa
José J. Costa

20 February 2015 in Journal of Building Physics
Verified
Journal Article
Closed access
CMCláudio Martins
Cláudio Martins
Paulo SantosPaulo Santos
Paulo Santos
LSLuís Simões da Silva
Luís Simões da Silva
In building applications (e.g. industrial, offices and residential), the use of lightweight steel-framed structural elements is increasing given its advantages, such as exceptional strength-to-weight relation, great potential for recycling and reuse, humidity shape stability, easy prefabrication and rapid on-site erection. However, the high thermal conductivity of steel presents a drawback, which may lead to thermal bridges if not well designed and executed. Furthermore, given the high number of steel profiles and its reduced thickness, it is not an easy task to accurately predict its thermal performance in laboratory and even less in situ. In a previous article, the authors studied the importance of flaking heat loss in lightweight steel-framed walls. This article discusses several thermal bridges mitigation strategies to improve a lightweight steel-framed wall model, which increase its thermal performance and reduce the energy consumption. The implementation of those mitigation strategies leads to a reduction of 8.3% in the U-value, comparatively to the reference case. An optimization of the wall module insulation layers is also performed (e.g. making use of new insulation materials: aerogel and vacuum insulation panels), which combined with the mitigation approaches allows a decrease of 68% in the U-value, also relatively to the reference case. Some design rules for lightweight steel-framed elements are also presented.

1 July 2021 in Thin-Walled Structures
Verified
Journal Article
Closed access
TTTrayana Tankova
Trayana Tankova
FRFilipe Rodrigues
Filipe Rodrigues
Carlos LeitaoCarlos Leitao
Carlos Leitao
CMCláudio Martins
Cláudio Martins
LSLuís Simões da Silva
Luís Simões da Silva

21 August 2013 in Journal of Building Physics
Verified
Journal Article
Closed access
Paulo SantosPaulo Santos
Paulo Santos
CMCláudio Martins
Cláudio Martins
LSLuís Simões da Silva
Luís Simões da Silva
Luís BragançaLuís Bragança
Luís Bragança
The thermal performance of a modular lightweight steel framed wall was measured and calculated with three-dimensional finite element method model. The focus of this article is on the effect of flanking thermal losses. The calculated heat flux values varied from −22% (external surface) to +50% (internal surface) when flanking loss was set to 0 as a reference case, thermal transmittance equal to 0.30 W/(m2·K). Other critical parameters were the existence of fixing ‘L’-shaped steel elements and the perimeter thermal insulation (10 cm XPS).

18 September 2014 in Metallurgical Research & Technology
Verified
Journal Article
Closed access
PDF file
Paulo SantosPaulo Santos
Paulo Santos
CMC. Martins
C. Martins
LSL. Simões da Silva
L. Simões da Silva
Lightweight steel-framed (LSF) structural elements in building construction provide a way of increasing building sustainability. These structural elements present great potential for recycling and reuse, allowing the conservation of natural resources and the environment. When compared with other materials, these construction components also provide other advantages: reduced weight with simultaneous high mechanical strength; easier prefabrication, allowing modular elements and higher quality control; shorter periods for assembling the building on-site; no dimensional variations caused by moisture; and low cost. The high thermal conductivity of steel could be a drawback, leading to thermal bridges if not well designed and executed. In the case of LSF components (e.g. walls and slabs) it is necessary to take special care with the elements’ design optimisation, with it being essential to use continuous thermal insulation. The building envelope thermal performance is crucial to provide good thermal behaviour and energy efficiency, allowing a reduction of operational energy. In this paper, the LSF construction system is analysed in order to show its main advantages and drawbacks. The assessment of embodied and operational energy is essential to perform a life cycle analysis. The reduction of both energies’ consumption is crucial to increase the sustainability label. Special focus will be given to the mitigation strategies of operational energy in LSF construction.

1 September 2019 in Journal of Building Engineering
Verified
Journal Article
Closed access
Paulo SantosPaulo Santos
Paulo Santos
MGMargarida Gonçalves
Margarida Gonçalves
CMCláudio Martins
Cláudio Martins
NSNelson Alexandre da Cruz Soares
Nelson Alexandre da Cruz Soares
JCJosé J. Costa
José J. Costa