SF6 gas has excellent dielectric strength and interrupting capability and is used in various applications such as gas insulated switchgear (GIS) in substations. However, since SF6 has a high global warming potential (GWP), it is imperative to reduce its use and develop recovery technology for its reuse. This paper examined the potential of alternative insulating gases for GIS, determining experimentally the ac and lightning impulse breakdown characteristics of CO2 and N2 gases, which have little environmental impact, in a quasi-uniform electric field. The effect of electrode surface roughness is greater in N2 than in CO2. The impulse ratio in a quasi-uniform electric field was smaller in N2 than in CO2 at low pressure, but this reversed when the pressure reached 1.2 MPa. The dielectric strength of an electrode with a dielectric coating was approximately equal to that of a specular-finish bare electrode in either CO2 or N2 when an ac voltage was applied. When lightning impulse voltage was applied, a significant improvement of dielectric strength was observed if a dielectric coating was applied to the electrode considered to be the initial electron source.
30 September 2009 in International Journal on Electrical Engineering and Informatics
International Journal on Electrical Engineering and Informatics is a quarterly publication peer reviewed journal in electrical engineering and informatics.
We aim to establish the advanced diagnostic technique for electric power transformer using online partial discharge measurement. This paper deals with propagation characteristic of acoustic waves emitted by partial discharges, or PDs in a simulated transformer which was composed of pressboard and mineral oil. PDs were generated by a rod-insulator-rod electrode immersed in mineral oil. The acoustic waves were measured with three AE sensors installed on the outside surface of the simulated transformer. PD-induced acoustic waves were also measured through pressboard, with attenuation characteristic of the acoustic waves considered. Numerical simulation allows us to understand the propagation characteristics of acoustic waves.
1 January 2007 in IEEJ Transactions on Fundamentals and Materials
Discharge characteristics in single-phase equipment are a well-known and well-established art, however, those in three-phase equipment are far less understood. Because the electric field in the insulating material of three-phase equipment is not linear, but rotates with power frequency, it can be expected that the discharge characteristics in three-phase equipment will be different from those in single-phase equipment. In this paper, the effects of rotating electric field on partial discharge pattern in a three-phase construction are reported. The simplified model of a three-phase GIS with air inside is used. The electric field in the construction was analyzed, and the discharge characteristics were observed. The electric field vector locus in a three-phase construction is elliptical, although the shape differs locally. The elliptical nature of rotating electric field is expressed as an electric field ratio. The experimental results showed that the phase widths where partial discharge current pulses appeared were different depending on the electric field ratio even for the same applied voltage. The phase width where partial discharge current pulses appeared was also influenced by the applied electric field. These results are analysed from the relationship between the value and the locus of the applied electric field and the critical electric field of air.
Investigation is made to establish a monitoring method for vacuum leakage from a vacuum interrupter (VI) using a discharge detection method. AC rated voltage is applied to a practical VI filled with air to cause partial discharge (PD) inside VI. A diagnostic method is studied using a number of sensors with different specification. An attempt is made to compare the detection sensitivity of PD for the various sensors. Experimental results reveal that the rise time and magnitude of PD signal waveform detected with each sensor vary depending on discharge phenomena occurring at different internal pressures of VI. As a result, it is suggested that PD detection with the suitable sensors can determine the internal pressure in VI, along with distinguishing PD signal from noise.