Jean-Marc Vrigneaud

Jean-Marc Vrigneaud

Auto-generated profile, based on publicly available information

Jean-Marc Vrigneaud

Centre Georges-François Leclerc, service de médecine nucléaire, CNRS, ICMUB UMR 6302, Université Bourgogne Europe, 21000, Dijon, France.

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2023 in Data
Verified
Journal Article
Open access
PDF file
FQFélix Quinton
Félix Quinton
RPRomain Popoff
Romain Popoff
BPBenoît Presles
Benoît Presles
SLSarah Leclerc
Sarah Leclerc
fabrice meriaudeaufabrice meriaudeau
fabrice meriaudeau
JAJean-Louis Alberini
Jean-Louis Alberini
Liver cancer is the sixth most common cancer in the world and the fourth leading cause of cancer mortality. In unresectable liver cancers, especially hepatocellular carcinoma (HCC), transarterial radioembolisation (TARE) can be considered for treatment. TARE treatment involves a contrast-enhanced magnetic resonance imaging (CE-MRI) exam performed beforehand to delineate the liver and tumour(s) in order to perform dosimetry calculation. Due to the significant amount of time and expertise required to perform the delineation process, there is a strong need for automation. Unfortunately, the lack of publicly available CE-MRI datasets with liver tumour annotations has hindered the development of fully automatic solutions for liver and tumour segmentation. The “Tumour and Liver Automatic Segmentation” (ATLAS) dataset that we present consists of 90 liver-focused CE-MRI covering the entire liver of 90 patients with unresectable HCC, along with 90 liver and liver tumour segmentation masks. To the best of our knowledge, the ATLAS dataset is the first public dataset providing CE-MRI of HCC with annotations. The public availability of this dataset should greatly facilitate the development of automated tools designed to optimise the delineation process, which is essential for treatment planning in liver cancer patients.

1 June 2018 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
JVJean-Marc Vrigneaud
Jean-Marc Vrigneaud
JMJohn McGrath
John McGrath
ACAlan Courteau
Alan Courteau
RPRosie Pegg
Rosie Pegg
AGAlberto Sanchez-Pastor Gomis
Alberto Sanchez-Pastor Gomis
FBFrançois Brunotte
François Brunotte
We evaluated the performance characteristics of a prototype preclinical PET scanner available as an easy clippable assembly that can dock to an MRI system. The single ring version of the PET system consists of eight detectors, each of which comprises a 12 × 12 silicon photomultipliers (SiPMs) array coupled with a dual layer of offset scintillation crystals to measure depth of interaction. The crystal arrays have 29 × 29 (30 × 30 for the outer layer) 4 mm long LYSO crystals (6 mm for the outer layer). The ring diameter is 119.2 mm and the axial field of view is 50.4 mm. The NEMA NU 4-2008 protocol was followed for studying the PET performance. Temperature stability of SiPMs was also investigated. The peak system absolute sensitivity was 4.70% with an energy window of 250–750 keV. The spatial resolution was 1.28/1.88/1.85 mm FWHM (radial/tangential/axial) at a distance of 5 mm from the center. Peak noise equivalent counting rate and scatter fraction for mouse phantom were 61.9 kcps at 14.9 MBq and 21.0%, respectively. The uniformity was 6.3% and the spill-over ratios in the images of the water-and air-filled chambers were 0.07 and 0.17, respectively. Recovery coefficients ranged from 0.13 to 0.96. Change in sensitivity as a function of ambient temperature was 0.3%/°C. These first results indicate excellent spatial resolution performance for use with animal studies. Moreover, the clippable assembly can be upgraded to accept a second ring of SiPMs modules, leading to improved sensitivity and axial coverage.

15 November 2013 in Medical Physics
Verified
Journal Article
Closed access
PDF file
JVJean‐Marc Vrigneaud
Jean‐Marc Vrigneaud
ACAlan Courteau
Alan Courteau
JRJulien Ranouil
Julien Ranouil
LMLoïc Morgand
Loïc Morgand
OROlivier Raguin
Olivier Raguin
FBFrançois Brunotte
François Brunotte

14 January 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
PJPellegrinelli Julie
Pellegrinelli Julie
OCOlivier CHEVALLIER
Olivier CHEVALLIER
SMsylvain manfredi
sylvain manfredi
IDInna Dygai-Cochet
Inna Dygai-Cochet
CTClaire Tabouret-Viaud
Claire Tabouret-Viaud
RLRomaric Loffroy
Romaric Loffroy
Liver tumors are common and may be unamenable to surgery or ablative treatments. Consequently, other treatments have been devised. To assess the safety and efficacy of transarterial radioembolization (TARE) with Yttrium-90 for hepatocellular carcinoma (HCC), liver-dominant hepatic colorectal cancer metastases (mCRC), and cholangiocarcinoma (CCA), performed according to current recommendations, we conducted a single-center retrospective study in 70 patients treated with TARE (HCC, n = 44; mCRC, n = 20; CCA, n = 6). Safety and toxicity were assessed using the National Cancer Institute Common Terminology Criteria. Treatment response was evaluated every 3 months on imaging studies using Response Evaluation Criteria in Solid Tumors (RECIST) or mRECIST criteria. Overall survival and progression-free survival were estimated using the Kaplan-Meier method. The median delivered dose was 1.6 GBq, with SIR-Spheres® or TheraSphere® microspheres. TARE-related grade 3 adverse events affected 17.1% of patients. Median follow-up was 32.1 months. Median progression-free survival was 5.6 months and median overall time from TARE to death was 16.1 months and was significantly shorter in men. Progression-free survival was significantly longer in women (HR, 0.49; 95%CI, 0.26–0.90; p = 0.031). Risk of death or progression increased with the number of systemic chemotherapy lines. TARE can be safe and effective in patients with intermediate- or advanced-stage HCC, CCA, or mCRC refractory or intolerant to appropriate treatments.

5 May 2017 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
PDF file
JVJ M Vrigneaud
J M Vrigneaud
PWP Walker
P Walker
BBB Barbier
B Barbier
ACA Camacho
A Camacho
AOA Oudot
A Oudot
FBF Brunotte
F Brunotte
The LabPET/MR imaging system is a new preclinical prototype with sequentially-acquired PET/MR scan capabilities. The dual modality system is composed of a modified APD-based LabPET4 subsystem, coupled with a cryogen-free superconducting 3.0 T MRI subsystem. The objective of the study was to characterize the imaging performance of the PET subsystem and identify the change in PET performance due to the presence of the magnetic field. NEMA NU-4-2008 performance characteristics were conducted with the MR subsystem switched ON and OFF. Influence of the temperature was also investigated by repeating selected performance tests. In the ON configuration, the radial/tangential FBP spatial resolution ranged from 1.62±0.08/1.88±0.08 mm to 2.83±0.11/2.03±0.03 mm at the axial center field of view. The peak absolute sensitivity for an energy window of 250-650 keV was 0.87%. The maximum noise equivalent counting rates were 133 kcps at 3.8 MBq ml-1 and 25 kcps at 0.4 MBq ml-1 for the mouse-and rat-like phantoms, respectively. The corresponding scatter fractions were 13% and 23%. No differences could be identified between the ON and OFF configuration, except for a mean loss in peak absolute sensitivity of 5.1±0.5% which was attributed to a mean rise in temperature of 1.2 °C when the magnet was ON. Compared with the LabPET standalone scanner, the LabPET/MR imaging prototype is working in a warmer environment and this impacts on the sensitivity of the APD-based LabPET scanner.

31 January 2024 in EJNMMI Physics
Verified
Journal Article
Open access
PDF file
AMAntoine Merlet
Antoine Merlet
BPBenoît Presles
Benoît Presles
KSKuan-Hao Su
Kuan-Hao Su
JSJulien Salvadori
Julien Salvadori
FSFarzam Sayah
Farzam Sayah
JVJean-Marc Vrigneaud
Jean-Marc Vrigneaud
Background: We propose a comprehensive evaluation of a Discovery MI 4-ring (DMI) model, using a Monte Carlo simulator (GATE) and a clinical reconstruction software package (PET toolbox). The following performance characteristics were compared with actual measurements according to NEMA NU 2-2018 guidelines: system sensitivity, count losses and scatter fraction (SF), coincidence time resolution (CTR), spatial resolution (SR), and image quality (IQ). For SR and IQ tests, reconstruction of time-of-flight (TOF) simulated data was performed using the manufacturer’s reconstruction software. Results: Simulated prompt, random, true, scatter and noise equivalent count rates closely matched the experimental rates with maximum relative differences of 1.6%, 5.3%, 7.8%, 6.6%, and 16.5%, respectively, in a clinical range of less than 10 kBq/mL. A 3.6% maximum relative difference was found between experimental and simulated sensitivities. The simulated spatial resolution was better than the experimental one. Simulated image quality metrics were relatively close to the experimental results. Conclusions: The current model is able to reproduce the behaviour of the DMI count rates in the clinical range and generate clinical-like images with a reasonable match in terms of contrast and noise.