26 February 2013 in International Journal of Sports Medicine
The aim of this study was to test the efficacy of the BEX Runner palm cooling device during a combination of exercise and environmental heat stress. Twelve subjects completed two randomly ordered time-to-exhaustion runs at 75% VO2max, 30 °C, and 50% relative humidity with and without palm cooling. Time to exhaustion runs started once the warm-up had elicited a core temperature of 37.5 °C. Heart rate, Rating of Perceived Exertion, Feeling Scale, and core temperature were recorded at 2-min intervals during each run. Time to exhaustion was longer in control than treatment (46.7±31.1 vs. 41.3±26.3 min, respectively, p<0.05); however, when warm-up time was included in analysis, there was no difference between trials for total exercise time (52.5±24.2 vs. 54.5±31.4 min, respectively). The rate-of-rise of core temperature was not different between control and treatment (0.047 vs. 0.048 °C · min−1, respectively). The use of the BEX Runner palm cooling device during a run in hot conditions did not eliminate or even attenuate the rise in core temperature. Exercise time in hot conditions did not increase with the use of the palm cooling device and time to exhaustion was reduced.
1 September 2017 in Medicine & Science in Sports & Exercise
. The purpose of this investigation was to determine whether V˙O2peak differed because of the manipulation of sampling intervals and whether differences were independent of the protocol and subject sample. Methods The first subject sample (24 ± 3 yr; V˙O2peak via 15-breath moving averages: 56.2 ± 6.8 mL·kg−1·min−1) completed the Bruce and the self-paced V˙O2max protocols. The second subject sample (21.9 ± 2.7 yr; V˙O2peak via 15-breath moving averages: 54.2 ± 8.0 mL·kg−1·min−1) completed the Bruce and the modified Astrand protocols. V˙O2peak was identified using five sampling intervals: 15-s block averages, 30-s block averages, 15-breath block averages, 15-breath moving averages, and 30-s block averages aligned to the end of exercise. Differences in V˙O2peak between intervals were determined using repeated-measures ANOVAs. The influence of subject sample on the sampling effect was determined using independent t-tests. Results There was a significant main effect of sampling interval on V˙O2peak (first sample Bruce and self-paced V˙O2maxP < 0.001; second sample Bruce and modified Astrand P < 0.05). The difference in V˙O2peak between sampling intervals followed a similar pattern for each protocol and subject sample, with 15-breath moving average presenting the highest V˙O2peak. Conclusions The effect of manipulating gas sampling intervals on V˙O2peak appears to be protocol and sample independent. These findings highlight our recommendation that the clinical and scientific community request and report the sampling interval whenever metabolic data are presented. The standardization of reporting would assist in the comparison of V˙O2peak....
5 June 2017 in European Journal of Applied Physiology
1 May 2015 in Medicine & Science in Sports & Exercise
1 May 2016 in Medicine & Science in Sports & Exercise
1 May 2017 in Medicine & Science in Sports & Exercise