Ya-Yong Huang

Ya-Yong Huang

Auto-generated profile, based on publicly available information

Ya-Yong Huang

Department of Radiology, Xuzhou Central Hospital, Xuzhou, China

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2019 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
YFYu-Fei Fu
Yu-Fei Fu
YGYong-Guang Gao
Yong-Guang Gao
MZMiao Zhang
Miao Zhang
TWTao Wang
Tao Wang
YSYi-Bing Shi
Yi-Bing Shi
YHYa-Yong Huang
Ya-Yong Huang
Video-assisted thoracoscopic surgery (VATS) has been widely used for diagnostic wedge resection of lung nodules. When VATS is performed for multiple lung nodules, preoperative localization for each target nodule is required. In this study, we evaluated the clinical effectiveness of computed tomography (CT)-guided simultaneous coil localization in one-stage VATS wedge resection for multiple lung nodules. Between November 2015 to March 2018, 19 patients with multiple target nodules underwent CT-guided simultaneous coil localization and one-stage VATS resection at our center. Data on the technical success of simultaneous localization and wedge resection, complications, and pathological results were collected. A total of 43 nodules were localized. The localization was successfully achieved in 42 of 43 nodules (97.7%). The technique of simultaneous localization was successfully achieved in 18 of 19 patients (94.7%). Fifteen patients underwent unilateral lung localization and four patients underwent bilateral lung localization. Three patients (15.8%) experienced asymptomatic pneumothorax after localization. All patients successfully underwent one-stage wedge resection for all target nodules. The mean duration of one-stage VATS procedure was 171.8 ± 84.0 min. The mean volume of blood loss was 94.2 ± 58.0 mL. Three patients experienced pleural effusion after VATS. During a follow-up of 6–31 months (median 18 months), no patient developed new lung nodules or distant metastasis. Preoperative simultaneous coil implantation is a safe and simple method for localization of multiple lung nodules. Simultaneous coil localization could effectively guide a one-stage VATS diagnostic wedge resection procedure.

4 March 2022 in Medicine
Verified
Journal Article
Open access
YLYong Li
Yong Li
FYFang Yang
Fang Yang
YHYa-Yong Huang
Ya-Yong Huang
WCWei Cao
Wei Cao
Background: This meta-analysis was conducted to compare the safety and diagnostic performance between computed tomography (CT)-guided core needle biopsy (CNB) and fine-needle aspiration biopsy (FNAB) in lung nodules/masses patients. Methods: All relevant studies in the Pubmed, Embase, and Cochrane Library databases that were published as of June 2020 were identified. RevMan version 5.3 was used for all data analyses. Results: In total, 9 relevant studies were included in the present meta-analysis. These studies were all retrospective and analyzed outcomes associated with 2175 procedures, including both CT-guided CNB (n = 819) and FNAB (n = 1356) procedures. CNB was associated with significantly higher sample adequacy rates than was FNAB (95.7% vs 85.8%, OR: 0.26; P < .00001), while diagnostic accuracy rates did not differ between these groups (90.1% vs 87.6%, OR: 0.8; P = .46). In addition, no differences in rates of pneumothorax (28.6% vs 23.0%, OR: 1.15; P = .71), hemorrhage (17.3% vs 20.1%, OR: 0.91; P = .62), and chest tube insertion (5.9% vs 4.9%, OR: 1.01; P = .97) were detected between these groups. Significant heterogeneity among included studies was detected for the diagnostic accuracy (I2 = 57%) and pneumothorax (I2 = 77%) endpoints. There were no significant differences between CNB and FNAB with respect to diagnostic accuracy rates for lung nodules (P = .90). In addition, we detected no evidence of significant publication bias. Conclusions: CT-guided CNB could achieve better sample adequacy than FNAB did during the lung biopsy procedure. However, the CNB did not show any superiorities in items of diagnostic accuracy and safety.

7 February 2022 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Closed access
YHYa-Yong Huang
Ya-Yong Huang
XLXia Liu
Xia Liu
YSYi-Bing Shi
Yi-Bing Shi
TWTao Wang
Tao Wang
To compare the clinical efficacy of computed tomography (CT)-guided localization needle and coil insertion as approaches to preoperative lung nodule (LN) localization.Between January 2018 and Decem...

31 December 2019 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Closed access
YFYu-Fei Fu
Yu-Fei Fu
CCChi Cao
Chi Cao
YSYi-Bing Shi
Yi-Bing Shi
WZWei Zhang
Wei Zhang
YHYa-Yong Huang
Ya-Yong Huang
Purpose: To assess the safety and clinical effectiveness of computed tomography (CT)-guided cryoablation for functional adrenal aldosteronoma. Material and methods: From June 2012 to December 2018, 11 patients with functional adrenal aldosteronoma underwent CT-guided cryoablation in our center. Data comprising complete ablation rate, clinical success rate, procedure-related complications and long-term outcome were collected and analyzed. Results: A total of 11 aldosteronoma in 11 patients were treated. Complete ablation was achieved in all patients after a single ablation session. No procedure-related complications occurred. Clinical success rate was 100%. Mean aldosterone levels, and systolic and diastolic pressure decreased from 858.6 ± 93.2 pmol/L, 156.4 ± 7.8 mmHg and 90.0 ± 10.5 mmHg prior to treatment, respectively, to 321.8 ± 41.2 pmol/L (p < .001), 129.1 ± 9.4 mmHg (p < .001) and 76.4 ± 5.5 mmHg (p = .005) after treatment, respectively. Mean renin and potassium improved from 0.2 ± 0.1 μg/L/h and 2.9 ± 0.2 mmol/L before treatment, respectively to 4.6 ± 0.4 μg/L/h (p < .001) and 4.2 ± 0.2 mmol/L (p < .001) following treatment, respectively. No tumor or clinical symptom recurrence occurred during the follow-up. Conclusions: CT-guided cryoablation is a safe and effective method for the treatment of functional adrenal aldosteronoma.

1 November 2022 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
YHYa-Yong Huang
Ya-Yong Huang
TWTao Wang
Tao Wang
YFYu-Fei Fu
Yu-Fei Fu
YSYi-Bing Shi
Yi-Bing Shi
WCWei Cao
Wei Cao
JHJu-Pan Hou
Ju-Pan Hou
Background: Recently, a new type of pulmonary nodule positioning needle has been adopted clinically. We aimed to evaluate the efficacy and safety of a new type of localization needles compared with coils for the simultaneous localization of multiple pulmonary nodules guided by computed tomography (CT) prior to video-assisted thoracoscopic surgery (VATS). Materials and methods: From January 2021 to March 2022, 87 pulmonary nodules from 40 patients were localized using the new localization needle. From January 2020 to December 2020, 68 pulmonary nodules in 31 patients were localized using coils. The relative outcomes were compared. Results: The success rate of pulmonary nodule localization in the needle group was 97.7% while that in the coil group was 98.5%. In the needle group, the time needed to locate the first nodule was significantly shorter than in the coil group (10.9 min vs. 17.2 min, P = 0.001). Moreover, the time needed per patient was also significantly shorter for the needle group compared with the coil group (23.7 min vs. 30 min, P = 0.017). The incidence of pneumothorax in the needle group was 25.0% vs. 12.9% in the coil group (P = 0.204). The rate of pulmonary hemorrhage in the needle group was 40.0% vs. 32.3% in the coil group (P = 0.502). The success rate of VATS wedge resection was 100% in both groups. Conclusion: Both disposable pulmonary nodule localization needles and coils are safe and effective for CT-guided localization of multiple pulmonary nodules of the same stage prior to VATS. However, the use of needles is time-saving compared with the use of coils. The coil localization may exhibit better safety than needle localization.

11 February 2022 in Journal of Cardiothoracic Surgery
Verified
Journal Article
Open access
PDF file
YLYong Li
Yong Li
FYFang Yang
Fang Yang
YHYa-Yong Huang
Ya-Yong Huang
TWTao Wang
Tao Wang
Stage I non-small-cell lung cancer (NSCLC) can be treated by both ablation and sublobar resection (SR). This meta-analysis was therefore designed to better compare the relative safety and efficacy of these two approaches to treating stage I NSCLC. Relevant studies published through November 2020 in the Cochrane Library, Embase, and PubMed databases were identified for analyses which were conducted with RevMan v5.3. In total, 816 potentially relevant articles were identified, of which 8 were ultimately included in the final meta-analysis. Patients in the SR group exhibited a signficantly lower pooled local recurrence (LR) rate (5.0% vs. 25.4%, P < 0.0001), although pooled distant recurrence (DR) rates were similar in both groups (25.7% vs. 23.1%, P = 0.75). The pooled hazard ratio (HR) for overall survival (OS) (HR: 1.23; 95% CI: 1.13–1.33, P < 0.00001), progression-free survival (PFS) (HR: 1.34; 95% CI: 1.15–1.55, P = 0.0002), and cancer-specific survival (HR: 1.39; 95% CI: 1.15–1.70, P = 0.0009) all indicated better survival outcomes among patients that underwent HR treatment, while pooled complication rates were similar in both groups (27.7% vs. 43.8%, P = 0.27). Patients that underwent ablation exhibited significantly shorter pooled post-operative hospitalization relative to those in the SR group (MD: 5.93; 95% CI: 0.78–11.07, P = 0.02). No evidence of publication bias was detected through funnel plot analyses. SR treatment of stage I NSCLC patients was associated with a lower LR rate and longer survival as compared to ablation.