Niklas Wester

Niklas Wester

Auto-generated profile, based on publicly available information

Niklas Wester

Department of Chemistry and Materials Science, School of Chemical Engineering Aalto University Helsinki Finland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2020 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
SSSami Sainio
Sami Sainio
NWNiklas Wester
Niklas Wester
AAAnja Aarva
Anja Aarva
CTCharles J. Titus
Charles J. Titus
DNDennis Nordlund
Dennis Nordlund
TLTomi Laurila
Tomi Laurila

16 October 2019 in ACS Omega
Verified
Journal Article
Open access
NWNiklas Wester
Niklas Wester
EMElsi Mynttinen
Elsi Mynttinen
JEJarkko Etula
Jarkko Etula
TLTuomas Lilius
Tuomas Lilius
EKEija Kalso
Eija Kalso
JKJari Koskinen
Jari Koskinen
In clinical settings, the dosing and differential diagnosis of the poisoning of morphine (MO) and codeine (CO) is challenging due to interindividual variations in metabolism. However, direct electrochemical detection of these analytes from biological matrices is inherently challenging due to interference from large concentrations of anions, such as ascorbic acid (AA) and uric acid (UA), as well as fouling of the electrode by proteins. In this work, a disposable Nafion-coated single-walled carbon nanotube network (SWCNT) electrode was developed. We show facile electron transfer and efficient charge separation between the interfering anions and positively charged MO and CO, as well as significantly reduced matrix effect in human plasma. The Nafion coating alters the voltammetric response of MO and CO, enabling simultaneous detection. With this SWCNT/Nafion electrode, two linear ranges of 0.05–1 and 1–10 μM were found for MO and one linear range of 0.1–50 μM for CO. Moreover, the selective and simultaneous detection of MO and CO was achieved in large excess of AA and UA, as well as, for the first time, in unprocessed human plasma. The favorable properties of this electrode enabled measurements in plasma with only mild dilution and without the precipitation of proteins.

10 January 2020 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
NWNiklas Wester
Niklas Wester
EMElsi Mynttinen
Elsi Mynttinen
JEJarkko Etula
Jarkko Etula
TLTuomas Lilius
Tuomas Lilius
EKEija Kalso
Eija Kalso
JKJari Koskinen
Jari Koskinen

26 August 2020 in Analytical Chemistry
Verified
Journal Article
Open access
NWNiklas Wester
Niklas Wester
BMBjørn F. Mikladal
Bjørn F. Mikladal
IVIlkka Varjos
Ilkka Varjos
APAntti Peltonen
Antti Peltonen
EKEija Kalso
Eija Kalso
JKJari Koskinen
Jari Koskinen
A disposable electrochemical test strip for quantitative point-of-care (POC) determination of acetaminophen (paracetamol) in plasma and finger-prick whole blood was fabricated. The industrially scalable dry transfer process of single-walled carbon nanotubes (SWCNT) and screen-printing of silver was combined to produce integrated electrochemical test-strips. Nafion coating stabilized the potential of the Ag reference electrode and enabled the selective detection in spiked plasma as well as in whole blood samples. The test strips were able to detect acetaminophen in small 40 µL samples with a detection limit of 0.8 µM and wide linear range from 1 µM to 2 mM, well within the required clinical range. After a simple 1:1 dilution of plasma and whole blood, quantitative detection with good recoveries of 79% in plasma and 74% in whole blood were achieved. These results strongly indicate that these electrodes can be used directly to determine the unbound acetaminophen fraction without the need for any additional steps. The developed test strip shows promise as a rapid and simple POC quantitative acetaminophen assay.

12 September 2019 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
VDVasuki Durairaj
Vasuki Durairaj
NWNiklas Wester
Niklas Wester
JEJarkko Etula
Jarkko Etula
TLTomi Laurila
Tomi Laurila
JLJanika Lehtonen
Janika Lehtonen
JKJari Koskinen
Jari Koskinen

14 June 2021 in ACS Applied Nano Materials
Verified
Journal Article
Open access
VDVasuki Durairaj
Vasuki Durairaj
PLPanpan Li
Panpan Li
TLTouko Liljeström
Touko Liljeström
NWNiklas Wester
Niklas Wester
JEJarkko Etula
Jarkko Etula
JKJari Koskinen
Jari Koskinen
Four different types of crystalline and fibrillar nanocellulosic materials with different functional groups (sulfate, carboxylate, amino-silane) are produced and used to disperse commercial multiwalled carbon nanotubes (MWCNT). Aqueous nanocellulose/MWCNT dispersions are drop-cast on tetrahedral amorphous carbon (ta-C) substrates to obtain highly stable composite electrodes. Their electrochemical properties are studied using cyclic voltammetry (CV) measurements with Ru(NH3)62+/3+, IrCl62–/3– redox probes, in electrolytes of different ionic strengths. All studied nanocellulose/MWCNT composites show excellent stability over a wide potential range (−0.6 to +1 V) in different electrolytes. Highly anionic and more porous fibrillar nanocellulosic composites indicate strong electrostatic and physical enrichment of cationic Ru(NH3)62+/3+ in lower-ionic-strength electrolytes, while lesser anionic and denser crystalline nanocellulosic composites show no such effects. This study provides essential insights into developing tailorable nanocellulose/carbon nanomaterial hybrid platforms for different electrochemical applications, by altering the constituent nanocellulosic material properties.