Rationale: A novel matrix‐free laser desorption/ionization method based on porous alumina membranes was developed. The porous alumina membranes have a two‐dimensional (2D) ordered structure consisting of closely aligned straight through holes of sub‐micron in diameter that are amenable to mass production by industrial fabrication processes. Methods: Considering a balance between the ion generating efficiency and the mechanical strength of the membranes, the typical values for the hole diameter, open aperture ratio and membrane thickness were set to 200 nm, 50% and 5 μm, respectively. The membranes were coated with platinum on a single side that was exposed to the laser. Evaluation experiments were conducted on the feasibility of this membrane structure for an ionization method using a single peptide and mixed peptides and polyethylene glycol samples and a commercial matrix‐assisted laser desorption/ionization (MALDI) time‐of‐flight mass spectrometer in the positive ion mode. Results: Results showed a softness of ionization and no sweet spot nature. The capillary action of the through holes with very high aspect ratio enables several loading protocols including sample impregnation from the surface opposite to the laser exposure side. Conclusions: The feasibility study indicates that the through hole porous alumina membranes have several advantages in terms of usefulness over the conventional surface‐assisted laser desorption ionization (SALDI) methods. The proposed novel ionization method is termed Desorption Ionization Using Through Hole Alumina Membrane (DIUTHAME).
17 January 2020 in Rapid Communications in Mass Spectrometry
Rationale: DIUTHAME (desorption ionization using through‐hole alumina membrane), a recently developed matrix‐free ionization‐assisting substrate, was examined for reproducibility in terms of mass accuracy and intensity using standard lipid and mouse brain sections. The impregnation property of DIUTHAME significantly improved the reproducibility of mass accuracy and intensity compared with 2,5‐dihydroxybenzoic acid (DHB). Methods: Frozen tissue sections were mounted on indium tin oxide‐coated glass slides. DIUTHAME and DHB were applied to individual sections. Subsequently, a solution of a phosphatidylcholine standard, PC(18:2/18:2), was poured onto the DIUTHAME and matrix. Finally, the samples were subjected to laser desorption ionization coupled with Fourier transform ion cyclotron resonance mass spectrometry. The reproducibility was tested by calculating the mean ± standard deviation values of mass errors and intensities of individual ion species. Results: Analysis of the PC(18:2/18:2) standard showed significantly ( p < 0.01) lower mass error for DIUTHAME‐MS than for MALDI‐MS. Endogenous PC(36:4) analysis in mouse brain section also showed significantly ( p < 0.05) lower mass errors for DIUTHAME‐MS. Furthermore, we investigated the mass error of some abundant lipid ions in brain sections and observed similar results. DIUTHAME‐MS displayed lower signal intensity in standard PC analysis. Interestingly, it offered higher signal intensities for all the endogenous lipid ions. Lower fluctuations of both mass accuracies and signal intensities were observed in DIUTHAME‐MS. Conclusions: Our results demonstrated that DIUTHAME‐MS offers higher reproducibility for mass accuracies and intensities than MALDI‐MS in both standard lipid and mouse brain tissue analyses. It can potentially be used instead of conventional MALDI‐MS and mass spectrometry imaging analyses to achieve highly reproducible data for mass accuracy and intensity.
In addition to identifying analytes from the time-of-flight of ions, stigmatic imaging mass spectrometry (IMS) realizes microscopic and high-throughput imaging of multiple mass-resolved molecules. However, practical applications require a fast position- and time-sensitive ion detector. We have developed a delay-line detector combined with analog-to-digital converters (ADCs), and evaluated its performance as an ion detector for stigmatic IMS using electron ionization. The system shows spatial and temporal resolutions of 230 µm and 24 ns (4.2 ×107 frames per second), respectively. We speculate that the timing jitter of the signals limits the spatial resolution due to the signal processing devices. At a 20-fold ion optical magnification and m/z of 10,000, the estimated spatial resolution and mass resolving power m/Δm using this ion detection system with a stigmatic imaging mass spectrometer, which we are currently developing, are 12 µm and 15,000, respectively.