Jasper Johns

Jasper Johns

Auto-generated profile, based on publicly available information

Jasper Johns

Institute for Occupational Safety and Health, German Social Accident Insurance, Sankt Augustin, Germany; Institute of Biomechanics and Orthopaedics, German Sport University Cologne, Cologne, Germany

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 August 2023 in International Journal of Industrial Ergonomics
Verified
Journal Article
Open access
LRLennart Ralfs
Lennart Ralfs
NHNiclas Hoffmann
Niclas Hoffmann
UGUlrich Glitsch
Ulrich Glitsch
KHKai Heinrich
Kai Heinrich
JJJasper Johns
Jasper Johns
RWRobert Weidner
Robert Weidner

27 April 2024 in Journal of Biomechanics
Verified
Journal Article
Closed access
JJJ. Johns
J. Johns
ISI. Schultes
I. Schultes
KHK. Heinrich
K. Heinrich
WPWolfgang Potthast
Wolfgang Potthast
UGU. Glitsch
U. Glitsch

26 April 2025 in International Journal of Industrial Ergonomics
Verified
Journal Article
Open access
JJJ. Johns
J. Johns
LKL. Krämer
L. Krämer
KHK. Heinrich
K. Heinrich
OEO. El-Edrissi
O. El-Edrissi
WPW. Potthast
W. Potthast
UGU. Glitsch
U. Glitsch

1 October 1990 in Choice Reviews Online
Verified
Journal Article
Closed access
NRNan Rosenthal
Nan Rosenthal
JJJasper Johns
Jasper Johns
RFRuth Fine
Ruth Fine
ÖBÖffentliche Kunstsammlung Basel
Öffentliche Kunstsammlung Basel
HGHayward Gallery
Hayward Gallery

16 May 2024 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
JJJasper Johns
Jasper Johns
ABA. Bender
A. Bender
UGUlrich Glitsch
Ulrich Glitsch
LSL. Schmidt-Bleek
L. Schmidt-Bleek
JDJ. Dymke
J. Dymke
KHKai Heinrich
Kai Heinrich
Industrial back support exoskeletons are a promising solution to alleviate lumbar musculoskeletal strain. Due to the complexity of spinal loading, evaluation of EMG data alone has been considered insufficient to assess their support effects, and complementary kinematic and dynamic data are required. However, the acquisition of marker-based kinematics is challenging with exoskeletons, as anatomical reference points, particularly on the pelvis, are occluded by exoskeleton structures. The aim of this study was therefore to develop and validate a method to reliably reconstruct the occluded pelvic markers. The movement data of six subjects, for whom pelvic markers could be placed while wearing an exoskeleton, were used to test the reconstructions and compare them to anatomical landmarks during lifting, holding and walking. Two separate approaches were used for the reconstruction. One used a reference coordinate system based on only exoskeleton markers (EXO), as has been suggested in the literature, while our proposed method adds a technical marker in the lumbar region (LUMB) to compensate for any shifting between exoskeleton and pelvis. Reconstruction with EXO yielded on average an absolute linear deviation of 54 mm +/- 16 mm (mean +/- 1SD) compared to anatomical markers. The additional marker in LUMB reduced mean deviations to 14 mm +/- 7 mm (mean +/- 1SD). Both methods were compared to reference values from the literature for expected variances due to marker placement and soft tissue artifacts. For LUMB 99% of reconstructions were within the defined threshold of 24 mm +/- 9 mm while for EXO 91% were outside.

31 December 2024 in Journal of Biomechanics
Verified
Journal Article
Closed access
JJJ. Johns
J. Johns
ISI. Schultes
I. Schultes
KHK. Heinrich
K. Heinrich
WPW. Potthast
W. Potthast
UGU. Glitsch
U. Glitsch