Soha Talih

Soha Talih

Auto-generated profile, based on publicly available information

Soha Talih

Department of Mechanical Engineering, American University of Beirut, Beirut, Lebanon

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 February 2019 in Tobacco Control
Verified
Journal Article
Closed access
PDF file
STSoha Talih
Soha Talih
RSRola Salman
Rola Salman
RERachel El-Hage
Rachel El-Hage
EKEbrahim Karam
Ebrahim Karam
NKNareg Karaoghlanian
Nareg Karaoghlanian
ASAlan Shihadeh
Alan Shihadeh
Introduction JUUL is an electronic cigarette (ECIG) with a compact form factor. It is prefilled with a liquid that is advertised to contain a high concentration of nicotine salt. JUUL commands 50% of the US ECIG market share, and its wide popularity with underage users has triggered unprecedented actions by the US FDA. Apart from its nicotine salt-containing liquid and compact form, a salient advertised design feature is a control circuit that limits the heating coil temperature, presumably reducing unwanted toxicants. In this study, several tobacco-flavoured JUUL devices were reverse engineered, and their aerosol emissions were studied. Methods Total nicotine and its partitioning (freebase and protonated), propylene glycol/vegetable glycerin (PG/VG) ratio, and carbonyls were quantified by gas chromatography (GC) and high performance liquid chromatography (HPLC). The temperature control functionality of JUUL was investigated using a temperature-controlled bath in which the coil was submerged. Results The liquid nicotine concentration was found to be 69 mg/mL, and the liquid and aerosol PG/VG ratio was found to be 30/70. In 15 puffs, JUUL emitted 2.05 (0.08) mg of nicotine, overwhelmingly in the protonated form. Carbonyl yields were significantly lower than those reported for combustible cigarettes, but similar to other closed-system ECIG devices. The heating coil resistance was 1.6 (0.66) Ohm, while the maximum power delivered by the JUUL device was 8.1 W. The control circuit limited the peak operating temperature to approximately 215C. Conclusions JUUL emits a high-nicotine concentration aerosol predominantly in the protonated form. JUUL’s nicotine-normalised formaldehyde and total aldehyde yields are lower than other previously studied ECIGs and combustible cigarettes.

12 May 2021 in Tobacco Control
Verified
Journal Article
Open access
PDF file
STSoha Talih
Soha Talih
RSRola Salman
Rola Salman
ESEric Soule
Eric Soule
RERachel El-Hage
Rachel El-Hage
EKEbrahim Karam
Ebrahim Karam
ASAlan Shihadeh
Alan Shihadeh
Introduction Use of flavoured pod-mod-like disposable electronic cigarettes (e-cigarettes) has grown rapidly, particularly among cost-sensitive youth and young adults. To date, little is known about their design characteristics and toxicant emissions. In this study, we analysed the electrical and chemical characteristics and nicotine and pulmonary toxicant emission profiles of five commonly available flavoured disposable e-cigarettes and compared these data with those of a JUUL, a cartridge-based e-cigarette device that pod-mod-like disposables emulate in size and shape. Methods Device construction, electrical power and liquid composition were determined. Machine-generated aerosol emissions including particulate matter, nicotine, carbonyl compounds and heavy metals were also measured. Liquid and aerosol composition were measured by high-performance liquid chromatography, gas chromatography-mass spectrometry/flame ionisation detection, and inductively coupled plasma mass spectrometry. Results We found that unlike JUUL, disposable devices did not incorporate a microcontroller to regulate electrical power to the heating coil. Quality of construction varied widely. Disposable e-cigarette power ranged between 5 and 9 W and liquid nicotine concentration ranged between 53 and 85 mg/mL (~95% in the protonated form). In 15 puffs, total nicotine yield for the disposables ranged between 1.6 and 6.7 mg, total carbonyls ranged between 28 and 138 µg, and total metals ranged between 1084 and 5804 ng. JUUL emissions were near the floors of all of these ranges. Conclusions Disposable e-cigarettes are designed with high nicotine concentration liquids and are capable of emitting much higher nicotine and carbonyl species relative to rechargeable look-alike e-cigarettes. These differences are likely due to the lower quality in construction, unreliable labelling and lack of temperature control regulation that limits the power during operation. From a public health perspective, regulating these devices is important to limit user exposure to carbonyls and nicotine, particularly because these devices are popular with youth and young adults.

29 September 2017 in Chemical Research in Toxicology
Verified
Journal Article
Closed access
STSoha Talih
Soha Talih
RSRola Salman
Rola Salman
NKNareg Karaoghlanian
Nareg Karaoghlanian
AEAhmad El-Hellani
Ahmad El-Hellani
NSNajat Aoun Saliba
Najat Aoun Saliba
ASAlan Shihadeh
Alan Shihadeh

19 December 2019 in Experimental and Clinical Psychopharmacology
Verified
Journal Article
Closed access
MHMarzena Hiler
Marzena Hiler
NKNareg Karaoghlanian
Nareg Karaoghlanian
STSoha Talih
Soha Talih
SMSarah Maloney
Sarah Maloney
ABAlison Breland
Alison Breland
TEThomas Eissenberg
Thomas Eissenberg
Electronic cigarette (ECIG) nicotine delivery and other effects can be influenced by device and/or liquid characteristics and user puffing behavior. One class of ECIGs includes "sub-ohm" devices that incorporate heating coils with resistance less than 1 ohm (Ω), lower than that observed in conventional devices (e.g., ≥1.5 Ω). Relative to conventional ECIGs that operate at ≤10 W, low-resistance coils can be used to increase device power (e.g., 40-300 W). However, little is known about the individual and combined effects of ECIG power, manipulated by coil resistance, and liquid nicotine concentration on ECIG acute effects. Experienced ECIG users (N = 32) completed 4 sessions that differed by ECIG power and coil resistance (40.5 W, 0.5 Ω or 13.5 W, 1.5 Ω) and liquid nicotine concentration (3 or 8 mg/ml). In each session, participants used a 4.5-V Kanger SUBOX ECIG in a 10-puff directed and 60-min ad libitum bout. Nicotine delivery, heart rate, subjective effects, puff topography, and liquid consumption were measured. Nicotine delivery was greatest in the 8mg/ml+0.5Ω condition and lowest in the 3mg/ml+1.5Ω condition. The greatest reduction in abstinence symptoms were observed in the 8mg/ml+0.5Ω condition, although the highest ratings for satisfaction and liking were reported in the 3mg/ml+0.5Ω condition. Use of ECIGs containing 3 mg/ml nicotine liquid resulted in longer and larger puffs and increased puff frequency, though high-power/low-resistance ECIGs resulted in greater consumption of ECIG liquid. ECIG device and liquid characteristics and user puff topography should be considered simultaneously when making regulatory decisions aimed at protecting public health. (PsycInfo Database Record (c) 2020 APA, all rights reserved).

22 July 2020 in Chemical Research in Toxicology
Verified
Journal Article
Closed access
STSoha Talih
Soha Talih
RSRola Salman
Rola Salman
EKEbrahim Karam
Ebrahim Karam
MEMario El-Hourani
Mario El-Hourani
RERachel El-Hage
Rachel El-Hage
ASAlan Shihadeh
Alan Shihadeh

13 May 2022 in Tobacco Control
Verified
Journal Article
Closed access
PDF file
MEMalak El-Kaassamani
Malak El-Kaassamani
MYMiaoshan Yen
Miaoshan Yen
STSoha Talih
Soha Talih
AEAhmad El-Hellani
Ahmad El-Hellani
Objective To highlight the general features of IQOS literature focusing on the chemical analysis of IQOS emissions. Data sources PubMed, Web of Science and Scopus databases were searched on 8 November 2021 using the terms ‘heated tobacco product’, ‘heat-not-burn’, ‘IQOS’ and ‘tobacco heating system’ with time restriction (2010–2021). The search yielded 5480 records. Study selection Relevant publications on topics related to IQOS assessment were retrieved (n=341). Two reviewers worked separately and reached agreement by consensus. Data extraction Data on author affiliation and funding, article type and date of publication were extracted. Publications were categorised depending on their focus and outcomes. Data on IQOS emissions from the chemical analysis category were extracted. Data synthesis Of the included publications, 25% were published by Philip Morris International (PMI) affiliates or PMI-funded studies. PMI-sponsored publications on emissions, toxicology assessments and health effects were comparable in number to those reported by independent research, in contrast to publications on IQOS use, market trends and regulation. Data on nicotine yield, carbonyl emissions, other mainstream emissions, secondhand emissions and IQOS waste were compared between data sources to highlight agreement or disagreement between PMI-sponsored and independent research. Conclusions Our analysis showed agreement between the data sources on nicotine yield from IQOS under the same puffing conditions. Also, both sources agreed that IQOS emits significantly reduced levels of some emissions compared with combustible cigarettes. However, independent studies and examination of PMI’s data showed significant increases in other emissions from and beyond the Food and Drug Administration’s harmful and potentially harmful constituents list.