Natalie Wilson

Natalie Wilson

Auto-generated profile, based on publicly available information

Natalie Wilson

The University of North Carolina at Chapel Hill School of Medicine, North Carolina, United States

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2023 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
NWNatalie Wilson
Natalie Wilson
MAMohamed Abdallah
Mohamed Abdallah
ASAllison R. Schulman
Allison R. Schulman
JMJeffrey D. Mosko
Jeffrey D. Mosko
ASAhmed Saeed
Ahmed Saeed
MBMohammad Bilal
Mohammad Bilal

31 January 2023 in Gastrointestinal Endoscopy
Verified
Journal Article
Closed access
PDF file
NWNatalie Wilson
Natalie Wilson
MAMohamed Abdallah
Mohamed Abdallah
MBMohammad Bilal
Mohammad Bilal

21 February 2023 in Obesity Surgery
Verified
Journal Article
Closed access
PDF file
NWNatalie Wilson
Natalie Wilson
MAMohamed Abdallah
Mohamed Abdallah
FJFouad Jaber
Fouad Jaber
WJWillie Mohammed Johnson
Willie Mohammed Johnson
NMNicholas McDonald
Nicholas McDonald
MBMohammad Bilal
Mohammad Bilal

10 September 2024 in VideoGIE
Verified
Journal Article
Open access
NWNatalie J. Wilson
Natalie J. Wilson
RKRahul Karna
Rahul Karna
GRGiovanni A. Roldan
Giovanni A. Roldan
RCRoberto Osorio Cintron
Roberto Osorio Cintron
ALAlexander Leaf
Alexander Leaf
MBMohammad Bilal
Mohammad Bilal
GI tract perforations during endoscopy can lead to serious adverse events such as tension pneumoperitoneum. In such cases, intraprocedural percutaneous needle decompression can be a lifesaving technique, in addition to allowing procedure completion. The aim of this study is to review the indications for percutaneous needle decompression and provide a step-by-step procedural guide with case examples. This review article and accompanying video review the technique for percutaneous needle decompression for pneumoperitoneum during endoscopy-related perforation, providing a step-by-step procedural guide illustrated with 2 case examples. In both case examples, intraprocedural needle decompression resulted in rapid normalization of hemodynamics and allowed time to safely complete the procedures after endoscopic closure of the perforation. Early recognition of pneumoperitoneum followed by intraprocedural percutaneous needle decompression with a large-bore catheter can allow time for defect closure and procedure completion or can serve as a temporizing measure until surgical intervention. Endoscopists should be comfortable performing this lifesaving technique in cases of endoscopy-related perforation and/or pneumoperitoneum.

14 October 2022 in Endoscopy
Verified
Journal Article
Open access
PDF file
NWNatalie Wilson
Natalie Wilson
NMNicholas McDonald
Nicholas McDonald
BMBryant Megna
Bryant Megna
MAMohamed Abdallah
Mohamed Abdallah
MBMohammad Bilal
Mohammad Bilal
Malignant gastroduodenal strictures are often managed with endoscopic stent placement [1]. One of the main limitations of duodenal self-expanding metal stents (SEMSs) is the risk of migration [2]. Multiple techniques have been used to prevent stent migration, including stent fixation using through-the-scope (TTS) clips, over-the-scope stent fixation devices, and endoscopic suturing [3] [4]. TTS suturing using the helix tack and suture device is a novel suturing method that is generally used for defect closure, though it has been rapidly gaining popularity for alternate uses [5]. A 73-year-old man with pancreatic adenocarcinoma on neoadjuvant chemotherapy presented with 3 weeks of vomiting and abdominal distension. Imaging showed pancreatic adenocarcinoma with duodenal obstruction. Esophagogastroduodenoscopy showed duodenal stenosis caused by tumor infiltration at the duodenal sweep ([Fig. 1 a, b]). The adult upper gastrointestinal (GI) endoscope was able to traverse the stenosis, which measured 2 cm in length, albeit with significant resistance. The tumor was borderline resectable, and according to our institutional protocol, endoscopic ultrasound-guided gastrojejunostomy is performed only for patients who are not surgical candidates; therefore, the decision was made to proceed with duodenal stent placement. An uncovered SEMS of 25 mm diameter and 10 cm length was placed across the stenosis ([Fig. 2]). Given the upper GI endoscope had been able to traverse the stenosis, it was decided to fix the position of the stent. This would reduce any migration before stent expansion and tissue ingrowth could act to keep the stent in place. The TTS suturing device was used (X-Tack; Apollo Endosurgery, Austin, Texas, USA) and the stent was fixed with four tacks placed in a stent-mucosa-mucosa-stent fashion ([Fig. 3], [Video 1]). Finally, the Cinch component was deployed. No adverse events were reported within the first 4 weeks of the procedure. Video 1 Duodenal stent fixation using the through-the-scope helix tack and suture device. Duodenal SEMSs are widely used in the setting of malignant gastroduodenal obstruction. While uncovered stents typically carry a lower risk of migration compared to covered stents [1] [2], in this case the apposition to the tissue was less than desired and thus the TTS suturing device was successfully used for stent fixation. Endoscopy_UCTN_Code_TTT_1AO_2AZ Article published online: 14 October 2022 © 2022. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany

4 January 2023 in Endoscopy
Verified
Journal Article
Open access
PDF file
NWNatalie Wilson
Natalie Wilson
MAMohamed Abdallah
Mohamed Abdallah
EPEric M. Pauli
Eric M. Pauli
MBMohammad Bilal
Mohammad Bilal
The through-the scope (TTS) helix tack-and-suture device (X-Tack; Apollo Endosurgery, Austin, Texas, USA) is a newer endoscopic suturing device used for closure of large defects after endoscopic resection [1] [2]. This device has recently been gaining popularity as a tool for stent fixation [1] [3] [4]. One of the limitations of this device for stent fixation is the lack of a dedicated removal tool. Here, we demonstrate two options for helical tack removal following application for stent fixation. A 74-year-old man with a benign duodenal peptic stricture presented for removal of a previously placed fully covered lumen-apposing metal stent that had been fixated using the TTS tack and suture device in stent-mucosa-mucosa-stent fashion. An upper endoscopy was performed and showed the previously placed stent in the first portion of the duodenum with four helical tacks and suture in place. The suture was cut using endoscopic scissors (Ensizor; Slater Endoscopy, Miramar, Florida, USA) followed by tack removal using a TTS rotatable endoclip (Resolution 360; Boston Scientific, Marlborough, Massachusetts, USA) and a rotatable rat tooth forceps (Raptor 360; Steris, Mentor, Ohio, USA) ([Video 1]). The stent was then successfully removed. No adverse events occurred. Video 1 Approaches to helical tack removal in a patient who underwent stent fixation with the X-tack device. The TTS tack-and-suture device was initially designed as a mucosal-based tissue closure device but more recently has been used for endoscopic device fixation [1] [3] [4]. One of the limitations for its use is the lack of a dedicated removal device, which can hamper stent removal and complicate future interventions where tack removal is necessary (e. g., reclosing a defect in the event of suture breakage around the tacks). First described by Pauli, endoscopic grasping devices capable of rotating in an anti-clockwise direction can be utilized to hold and unscrew helical tacks [5]. In this case, the rotatable endoclip and rotatable rat tooth forceps were used to remove the tacks. It is also important to note that when the stent was initially placed, a degree of laxity on the suture was intentionally maintained to facilitate cutting of the suture for subsequent stent removal. These methods may serve as a useful insight for endoscopists when using the TTS tack-and-suture device for stent fixation or when a need arises to remove tacks for other indications. Endoscopy_UCTN_Code_TTT_1AR_2AG Article published online: 15 June 2023 © 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/) Georg Thieme Verlag KG Rüdigerstraße 14, 70469 Stuttgart, Germany