1 September 2016 in Scientific Reports
Air sacs are thought to be the bellows for insect respiration. However, their exact mechanism of action as a bellows remains unclear. A direct way to investigate this problem is in vivo observation of the changes in their three-dimensional structures. Therefore, four-dimensional X-ray phase contrast microtomography is employed to solve this puzzle. Quantitative analysis of three-dimensional image series reveals that the compression of the air sac during respiration in bell crickets exhibits obvious anisotropic characteristics both longitudinally and transversely. Volumetric changes of the tracheal trunks in the prothorax further strengthen the evidence of this finding. As a result, we conclude that the shrinkage and expansion of the insect air sac is anisotropic, contrary to the hypothesis of isotropy, thereby providing new knowledge for further research on the insect respiratory system.
30 November 2010 in Journal of Surgical Research
12 October 2017 in Applied Optics
Small-angle x-ray scattering computed tomography (SAXS-CT) is a nondestructive method for the nanostructure analysis of heterogeneous materials. However, the limits of a long data acquisition time and vast amounts of data prevent SAXS-CT from becoming a routine experimental method in the applications of synchrotron radiation. In this study, the ordered subsets expectation maximization (OSEM) algorithm is introduced to improve the efficiency of SAXS-CT. To demonstrate the practicability of this method, a systematic simulation and experiments were carried out. The simulation results on a numerical phantom show that the OSEM-based SAXS-CT can effectively eliminate streaking artifacts and improve the efficiency of data acquisition by at least 3 times compared with the filter backprojection algorithm. By compromising the reconstruction speed and image quality, the optimal reconstruction parameters are also given for the image reconstruction in the OSEM-based SAXS-CT experiments. An experiment on a bamboo sample verified the validity of the proposed method with limited projection data. A further experiment on polyethylene demonstrated that the OSEM-based SAXS-CT is able to reveal the local nanoscale information about the crystalline structure and distributional difference inside the sample. In conclusion, the OSEM-based SAXS-CT can significantly improve experimental efficiency, which may promote SAXS-CT becoming a conventional method.
30 April 2018 in Nuclear Science and Techniques
31 July 2017 in Journal of X-Ray Science and Technology
Monochromatic-beam-based dynamic X-ray computed microtomography (CT) was developed to observe evolution of microstructure inside samples. However, the low flux density results in low efficiency in data collection. To increase efficiency, reducing the number of projections should be a practical solution. However, it has disadvantages of low image reconstruction quality using the traditional filtered back projection (FBP) algorithm. In this study, an iterative reconstruction method using an ordered subset expectation maximization-total variation (OSEM-TV) algorithm was employed to address and solve this problem. The simulated results demonstrated that normalized mean square error of the image slices reconstructed by the OSEM-TV algorithm was about 1/4 of that by FBP. Experimental results also demonstrated that the density resolution of OSEM-TV was high enough to resolve different materials with the number of projections less than 100. As a result, with the introduction of OSEM-TV, the monochromatic-beam-based dynamic X-ray microtomography is potentially practicable for the quantitative and non-destructive analysis to the evolution of microstructure with acceptable efficiency in data collection and reconstructed image quality.
10 August 2018 in Microscopy and Microanalysis