Liliane Nguyen

Liliane Nguyen

Auto-generated profile, based on publicly available information

Liliane Nguyen

ISE, Institute for Environmental Sciences, University of Geneva, Geneva, Switzerland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2020 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
EBEliane Maillard Barras
Eliane Maillard Barras
AHAlexander Haefele
Alexander Haefele
LNLiliane Nguyen
Liliane Nguyen
FTFiona Tummon
Fiona Tummon
WBWilliam T. Ball
William T. Ball
IBIan Boyd
Ian Boyd
Reliable ozone trends after 2000 are essential to detect early ozone recovery. However, the long-term ground-based and satellite ozone profile trends reported in the literature show a high variability. There are multiple reasons for variability in the reported long-term trends such as the measurement timing and the dataset quality. The Payerne Switzerland microwave radiometer (MWR) ozone trends are significantly positive at 2 % to 3 % per decade in the upper stratosphere (5–1 hPa, 35–48 km), with a high variation with altitude. This is in accordance with the Northern Hemisphere (NH) trends reported by other ground-based instruments in the SPARC LOTUS project. In order to determine what part of the variability between different datasets comes from measurement timing, Payerne MWR and SOCOL v3.0 chemistry–climate model (CCM) trends were estimated for each hour of the day with a multiple linear regression model. Trends were quantified as a function of local solar time (LST). In the middle and upper stratosphere, differences as a function of LST are reported for both the MWR and simulated trends for the post-2000 period. However, these differences are not significant at the 95 % confidence level. In the lower mesosphere (1–0.1 hPa, 48–65 km), the 2010–2018 day- and nighttime trends have been considered. Here again, the variation in the trend with LST is not significant at the 95 % confidence level. Based on these results we conclude that significant trend differences between instruments cannot be attributed to a systematic temporal sampling effect. The dataset quality is of primary importance in a reliable trend derivation, and multi-instrument comparison analyses can be used to assess the long-term stability of data records by estimating the drift and bias of instruments. The Payerne MWR dataset has been homogenized to ensure a stable measurement contribution to the ozone profiles and to take into account the effects of three major instrument upgrades. At each instrument upgrade, a correction offset has been calculated using parallel measurements or simultaneous measurements by an independent instrument. At pressure levels smaller than 0.59 hPa (above ∼50 km), the homogenization corrections to be applied to the Payerne MWR ozone profiles are dependent on LST. Due to the lack of reference measurements with a comparable measurement contribution at a high time resolution, a comprehensive homogenization of the sub-daily ozone profiles was possible only for pressure levels larger than 0.59 hPa. The ozone profile dataset from the Payerne MWR, Switzerland, was compared with profiles from the GROMOS MWR in Bern, Switzerland, satellite instruments (MLS, MIPAS, HALOE, SCHIAMACHY, GOMOS), and profiles simulated by the SOCOL v3.0 CCM. The long-term stability and mean biases of the time series were estimated as a function of the measurement time (day- and nighttime). The homogenized Payerne MWR ozone dataset agrees within ±5 % with the MLS dataset over the 30 to 65 km altitude range and within ±10 % of the HARMonized dataset of OZone profiles (HARMOZ, limb and occultation measurements from ENVISAT) over the 30 to 65 km altitude range. In the upper stratosphere, there is a large nighttime difference between Payerne MWR and other datasets, which is likely a result of the mesospheric signal aliasing with lower levels in the stratosphere due to a lower vertical resolution at that altitude. Hence, the induced bias at 55 km is considered an instrumental artifact and is not further analyzed.

17 February 2020 in EGUsphere
Verified
Preprint
Open access
EBEliane Maillard Barras
Eliane Maillard Barras
AHAlexander Haefele
Alexander Haefele
LNLiliane Nguyen
Liliane Nguyen
FTFiona Tummon
Fiona Tummon
WBWilliam T. Ball
William T. Ball
IBIan Boyd
Ian Boyd
Multi-instrument comparison analyses are essential to assess the long-term stability of data records by estimating the drift and bias of instruments. The ozone profile dataset from the SOMORA microwave radiometer (MWR) in Payerne, Switzerland, was compared with profiles from the GROMOS MWR in Bern, Switzerland, satellite instruments (MLS, MIPAS, HALOE, SCHIAMACHY, GOMOS), and profiles simulated by the SOCOL v3.0 chemistry-climate model (CCM). The Payerne MWR dataset has been homogenized to ensure a stable measurement contribution to the ozone profiles and to take into account the effects of three major instrument upgrades. At pressure levels smaller than 0.59 hPa (above ~ 50 km), the homogenization corrections to be applied to the Payerne MWR ozone profiles are dependent on local solar time (LST). Due to the lack of reference measurements with a comparable measurement contribution at a high time resolution, a comprehensive homogenization of the sub-daily ozone profiles was possible only for pressure levels larger than 0.59 hPa. The long-term stability and mean biases of the time series were estimated as a function of the measurement time (day- and nighttime). The homogenized Payerne MWR ozone dataset agrees within ± 5 % with the MLS dataset over the 30 to 65 km altitude range and within ± 10 % of HARMOZ datasets over the 30 to 65 km altitude range. In the upper stratosphere, there is a large nighttime difference between Payerne MWR and other datasets, which is likely a result of the mesospheric signal aliasing with lower levels in the stratosphere due to a lower vertical resolution at that altitude. Hence, the induced bias at 55 km is considered an instrumental artefact and is not further analyzed and discussed. In the upper stratosphere (5–1 hPa, 35–48 km), the Payerne MWR trends are significantly positive at 2 to 3 %/decade. This is in accordance with the northern hemisphere (NH) trends reported by other ground-based instruments in the SPARC LOTUS project. The reason for variability in the reported long-term ground-based and satellite ozone profile trends has multiple possibilities. To determine what part of the variability comes from measurement timing, MWR trends were estimated for each hour of the day with a multiple linear regression model to quantify trends as a function of LST. In the mid- and upper stratosphere, differences as a function of LST are reported for both the MWR and simulated trends for the 2000–2016 period. However, these differences are not significant at the 95 % confidence level. In the lower mesosphere (1–0.1 hPa, 48–65 km), the 2010–2018 day- and nighttime trends have been considered. Here again, the variation of the trend with LST is not significant at the 95 % confidence level. Based on these results we conclude that trend differences between instruments cannot to be attributed to a systematic temporal sampling.