21 January 2026 in Radiology Advances
Background: Synovitis is the key inflammatory feature of rheumatoid arthritis (RA). Quantitative assessment of synovitis better correlates with patient outcomes than semiquantitative assessment but it is time-consuming. Purpose: To develop and validate an automated model for segmentation and quantification of wrist synovial tissue volume on postcontrast fat-suppressed T1-weighted MRI. Material and Methods: Patients with early RA (symptoms for ≤24 months) at a single center were recruited at baseline and were followed up at year 1 and year 8. Postcontrast axial fat-suppressed T1-weighted images of the most symptomatic wrist were acquired at 3.0 T. One observer manually segmented consecutive synovitis areas on all MRI datasets. A framework, based on the convolutional neural network, nnU-Net, was trained and validated (5-fold cross-validation with image level splits) with 295 image datasets used for model training and validation. The rheumatoid arthritis MRI score was used to semiquantitatively grade synovitis. Manually segmented synovial volume by a single reader was used as the reference standard. Forty-five external image datasets from 2 different imaging centers were used to test generalizable applicability. Results: For automated synovitis segmentation, the overall Sørensen-Dice similarity coefficient (DSC) was 0.75 ± 0.11 (mean ± SD) compared to manual segmentation. Higher DSC values were found in patients with moderate (0.80 ± 0.06) and severe (0.84 ± 0.05) degrees of synovitis. The model had a similar performance with externally acquired data (DSC value: 0.70 ± 0.20). Predicted and manually segmented synovitis volume measurements showed excellent agreement (Pearson correlation: r = 0.975, P < .001). Conclusion: A fully automated model quantified wrist synovial tissue volume with good agreement to manual reference and maintained performance on external data, supporting potential use in clinical studies and prospective evaluation in practice.
21 August 2025 in Clinical Radiology
To evaluate the distraction effect, intrinsic structure visibility, and wearability of a novel direct wrist traction device for wrist magnetic resonance (MR) imaging. A total of 34 healthy subjects underwent wrist MR imaging initially without traction and then with traction using a direct traction device and were enrolled in this study. Joint space width, articular cartilage visibility, intrinsic ligaments and triangular fibrocartilage complex (TFCC) visibility, and lesion detection were assessed before and after traction. A 10-point visual analogue scale (VAS) questionnaire was used to assess pain during MRI. Paired sample t-test and marginal homogeneity test were used to compare joint space width, articular cartilage and intrinsic ligament visibility before and after traction, respectively. Mean joint space width was 0.7 ± 0.34 mm wider after traction (adjusted P < 0.001). Articular cartilage visibility improved at the radiolunate, scaphocapitate, and lunocapitate joints after traction (all adjusted P < 0.001). Intrinsic ligaments and TFCC lesion detection tended to improve following traction with improved visibility. Twenty-one (62%) of 34 subjects had no wrist pain during traction while 13 (38%) had an average increase of 2.6 VAS points in wrist pain. No subjects had shoulder or neck pain. This direct traction device effectively distracts the wrist joint, which may potentially improve articular cartilage visibility as well as the detection of intrinsic ligament and TFCC lesions.