Jaime L. Shaw

Jaime L. Shaw

Auto-generated profile, based on publicly available information

Jaime L. Shaw

Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, CA, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2018 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
ACAnthony G. Christodoulou
Anthony G. Christodoulou
JSJaime L. Shaw
Jaime L. Shaw
CNChristopher Nguyen
Christopher Nguyen
QYQi Yang
Qi Yang
YXYibin Xie
Yibin Xie
DLDebiao Li
Debiao Li

19 November 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
JSJaime L. Shaw
Jaime L. Shaw
QYQi Yang
Qi Yang
ZZZhengwei Zhou
Zhengwei Zhou
ZDZixin Deng
Zixin Deng
CNChristopher Nguyen
Christopher Nguyen
ACAnthony G. Christodoulou
Anthony G. Christodoulou

30 May 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ZZZhengwei Zhou
Zhengwei Zhou
PHPei Han
Pei Han
BZBill Zhou
Bill Zhou
ACAnthony G. Christodoulou
Anthony G. Christodoulou
JSJaime L. Shaw
Jaime L. Shaw
DLDebiao Li
Debiao Li

1 December 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
ZZZhengwei Zhou
Zhengwei Zhou
CNChristopher Nguyen
Christopher Nguyen
YCYuhua Chen
Yuhua Chen
JSJaime L. Shaw
Jaime L. Shaw
ZDZixin Deng
Zixin Deng
DLDebiao Li
Debiao Li
Previous studies have linked cardiac dysfunction to loss of metabolites in the creatine kinase system. Chemical exchange saturation transfer (CEST) is a promising metabolic cardiovascular magnetic resonance (CMR) imaging technique and has been applied in the heart for creatine mapping. However, current limitations include: (a) long scan time, (b) residual cardiac and respiratory motion, and (c) B0 field variations induced by respiratory motion. An improved CEST CMR technique was developed to address these problems. Animals with chronic myocardial infarction (N = 15) were scanned using the proposed CEST CMR technique and a late gadolinium enhancement (LGE) sequence as reference. The major improvements of the CEST CMR technique are: (a) Images were acquired by single-shot FLASH, significantly increasing the scan efficiency. (b) All images were registered to reduce the residual motion. (c) The acquired Z-spectrum was analyzed using 3-pool-model Lorentzian-line fitting to generate CEST signal, reducing the impact of B0 field shifting due to respiratory motion. Feasibility of the technique was tested in a porcine model with chronic myocardial infarction. CEST signal was measured in the scar, border zone and remote myocardium. Initial studies were performed in one patient. In all animals, healthy remote myocardial CEST signal was elevated (0.16 ± 0.02) compared to infarct CEST signal (0.09 ± 0.02, P < 0.001) and the border zone (0.12 ± 0.02, P < 0.001). For both animal and patient studies, the hypointense regions in the CEST contrast maps closely match the bright areas in the LGE images. The proposed CEST CMR technique was developed to address long scan times, respiratory and cardiac motion, and B0 field variations. Lower CEST signal in bright region of the LGE image is consistent with the fact that myocardial infarction has reduced metabolic activity.

1 February 2024 in Circulation: Cardiovascular Imaging
Verified
Journal Article
Closed access
YZYang Zhan
Yang Zhan
MFMatthias G. Friedrich
Matthias G. Friedrich
NDNandini Dendukuri
Nandini Dendukuri
YLYang Lu
Yang Lu
MCMichael Chetrit
Michael Chetrit
JAJonathan Afilalo
Jonathan Afilalo
BACKGROUND: Cardiovascular magnetic resonance (CMR) reference values are relied upon to accurately diagnose left ventricular (LV) and right ventricular (RV) pathologies. To date, reference values have been derived from modest sample sizes with limited patient diversity and attention to 1 but not both commonly used tracing techniques for papillary muscles and trabeculations. We sought to overcome these limitations by meta-analyzing normal reference values for CMR parameters stemming from multiple countries, vendors, analysts, and patient populations. METHODS: We comprehensively extracted published and unpublished data from studies reporting CMR parameters in healthy adults. A steady-state free-precession short-axis stack at 1.5T or 3T was used to trace either counting the papillary muscles and trabeculations in the LV volume or mass. We used a novel Bayesian hierarchical meta-analysis model to derive the pooled lower and upper reference values for each CMR parameter. Our model accounted for the expected differences between tracing techniques by including informative prior distributions from a large external data set. RESULTS: A total of 254 studies from 25 different countries were systematically reviewed, representing 12 812 healthy adults, of which 52 were meta-analyzed. For LV parameters counting papillary muscles and trabeculations in the LV volume, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 52% to 73% and 54% to 75%, LV end-diastolic volume index of 60 to 109 and 56 to 96 mL/m 2 , LV end-systolic volume index of 18 to 45 and 16 to 38 mL/m 2 , and LV mass index of 41 to 76 and 33 to 57 g/m 2 . For LV parameters counting papillary muscles and trabeculations in the LV mass, pooled normative reference ranges in men and women, respectively, were as follows: LV ejection fraction of 57% to 74% and 57% to 75%, LV end-diastolic volume index of 60 to 97 and 55 to 88 mL/m 2 , LV end-systolic volume index of 18 to 37 and 15 to 34 mL/m 2 , and LV mass index of 50 to 83 and 38 to 65 g/m 2 . For RV parameters, pooled normative reference ranges in men and women, respectively, were as follows: RV ejection fraction of 47% to 68% and 49% to 71%, RV end-diastolic volume index of 64 to 115 and 57 to 99 mL/m 2 , RV end-systolic volume index of 23 to 52 and 18 to 42 mL/m 2 , and RV mass index of 14 to 29 and 13 to 25 g/m 2 . CONCLUSIONS: Our Bayesian hierarchical meta-analysis provides normative reference values for CMR parameters of LV and RV size, systolic function, and mass, encompassing both tracing techniques across a diverse multinational sample of healthy men and women.

1 January 2013 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
HRHussein Rayatzadeh
Hussein Rayatzadeh
ATAlex Tan
Alex Tan
RCRaymond H Chan
Raymond H Chan
SPShalin J Patel
Shalin J Patel
THThomas H Hauser
Thomas H Hauser
RNReza Nezafat
Reza Nezafat
Despite the survival benefit of implantable-cardioverter-defibrillators (ICDs), the vast majority of patients receiving an ICD for primary prevention do not receive ICD therapy. We sought to assess the role of heterogeneous scar area (HSA) identified by late gadolinium enhancement cardiovascular magnetic resonance (LGE-CMR) in predicting appropriate ICD therapy for primary prevention of sudden cardiac death (SCD).