Jung Taek Im

Jung Taek Im

Auto-generated profile, based on publicly available information

Jung Taek Im

Department of Orthopaedic Surgery, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2025 in Clinics in Shoulder and Elbow
Verified
Journal Article
Open access
PDF file
HLHee Dong Lee
Hee Dong Lee
YCYun Seong Choi
Yun Seong Choi
WLWoo Seung Lee
Woo Seung Lee
JIJung Taek Im
Jung Taek Im
JYJae Chul Yoo
Jae Chul Yoo
Background: Humeral version is a key parameter in preoperative planning for reverse total shoulder arthroplasty (RTSA). Although computed tomography (CT) of the entire humerus is required to measure humeral version accurately, standard preoperative imaging typically includes only the scapula and proximal humerus, leading to additional radiation exposure. Ultrasound-assisted humeral torsion measurement using the bicipital groove has shown strong correlations with CT but lacks clinically applicable angle calculation methods. Methods: In this study, we evaluate whether humeral version can be accurately calculated using proximal humerus CT combined with ultrasound without additional imaging of the distal humerus. Thirty-nine patients who underwent RTSA between March 2021 and May 2022 were included. Preoperative whole-humerus CT and ultrasound-assisted version measurements were compared. Results: Intra- and inter-tester reliability of the ultrasound-assisted measurements showed intraclass correlation coefficients (ICCs) of 0.924 (95% CI, 0.857–0.960) and 0.872 (95% CI, 0.727–0.942), respectively. The mean humeral version measured by CT was 30.4°±15.1°, and 32.8°±14.5° by the ultrasound-assisted method. A strong correlation was observed between the two methods (Pearson’s r=0.915, P<0.001; concordance correlation coefficient=0.903). The ICC between the two methods was 0.905 (95% CI, 0.813–0.951). Bland-Altman analysis showed a mean difference of 2.38°, with 95% limits of agreement from –14.37° to 9.61°, indicating high agreement. Conclusions: These findings suggest that ultrasound-assisted measurement combined with proximal humerus CT is a reliable and accurate alternative to whole-humerus CT, reducing radiation exposure and cost.Level of evidence: III.

1 January 2024 in Journal of the Korean Orthopaedic Association
Verified
Journal Article
Open access
PDF file
HSHun-Kyu Shin
Hun-Kyu Shin
JIJung-Taek Im
Jung-Taek Im
JLJunYeop Lee
JunYeop Lee
JPJai Hyung Park
Jai Hyung Park
신헌규, et al. J Korean Orthop Assoc. 2024 Apr;59(2):126-131. https://doi.org/10.4055/jkoa.2024.59.2.126

1 January 2024 in Journal of the Korean Orthopaedic Association
Verified
Journal Article
Open access
PDF file
HSHun Kyu Shin
Hun Kyu Shin
JIJung Taek Im
Jung Taek Im
JSJeong-In Shon
Jeong-In Shon
JPJai Hyung Park
Jai Hyung Park
신헌규, et al. J Korean Orthop Assoc. 2024 Dec;59(6):436-440. https://doi.org/10.4055/jkoa.2024.59.6.436

1 January 2025 in Journal of the Korean Orthopaedic Association
Verified
Journal Article
Open access
PDF file
HSHun Kyu Shin
Hun Kyu Shin
JIJung Taek Im
Jung Taek Im
JSJeong-In Shon
Jeong-In Shon
CJChangkyun Jeong
Changkyun Jeong
JPJai Hyung Park
Jai Hyung Park
신헌규, et al. J Korean Orthop Assoc. 2025 Jun;60(2):98-102. https://doi.org/10.4055/jkoa.2025.60.2.98