Wenjing Li

Wenjing Li

Auto-generated profile, based on publicly available information

Wenjing Li

Translational Research in Ultrasound Theranostics Laboratory, School of Biomedical Engineering, ShanghaiTech University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2025 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
WLWenjing Li
Wenjing Li
YFYifan Feng
Yifan Feng
ZXZhouyang Xu
Zhouyang Xu
XXXing Xu
Xing Xu
KYKexin Yang
Kexin Yang
BCBingbing Cheng
Bingbing Cheng
Precise, noninvasive drug delivery to small but important brain regions is challenging and highly desired given the brain’s inherent complexity and heterogeneous nature. Here, we report an approach utilizing focused ultrasound (FUS) combined with nanobubbles to successfully navigate this challenge. Compared to traditional microbubbles, nanobubbles exhibit superior acoustic properties. The nanobubbles, when exposed to FUS, induce a highly localized and reversible opening of the blood–brain barrier (BBB) with significantly enhanced precision (up to fourfolds compared to microbubbles, as measured by the precision loss metric). Repeated multitarget FUS-NB precisely delivers macromolecular human-derived anti-N-methyl-D-aspartate receptors monoclonal antibodies (HuMAbs) into the small brain region within a 2-h half-life window per opening. Fluorescence images confirm HuMAb retention in the brain parenchyma for at least 10 d postadministration. With this approach, we targeted the lateral habenula, a small but effective brain target for antidepressant treatments, and significantly alleviated depression-like symptoms at least 2 wk in a mouse model (tail suspension test/forced swim test: P < 0.01/0.05). Moreover, minimal red blood cell extravasation (0.9‱ affected area) was observed in the treated region after multiple FUS treatments, indicating the safety and tolerability of FUS-nanobubble-mediated BBB opening. The enhanced delivery precision, coupled with a favorable safety profile, positions our approach as a promising strategy for antibody therapy with significant clinical translation potential.

2 December 2024 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HDHaixin Dai
Haixin Dai
WLWenjing Li
Wenjing Li
QWQian Wang
Qian Wang
BCBingbing Cheng
Bingbing Cheng
Objective: Targeted blood-brain barrier (BBB) opening using focused ultrasound (FUS) and micro/nanobubbles is a promising method for brain drug delivery. This study aims to explore the feasibility of multiple instance learning (MIL) in accurate and fast prediction of FUS BBB opening outcomes. Methods: FUS BBB opening experiments are conducted on 52 mice with the infusion of SonoVue microbubbles or custom-made nanobubbles. Acoustic signals collected during the experiments are transformed into frequency domain and used as the dataset. We propose a Simple Transformer-based model for BBB Opening Prediction (SimTBOP). By leveraging the self-attention mechanism, our model considers the contextual relationships between signals from different pulses in a treatment and aggregates this information to predict the BBB opening outcomes. Multiple preprocessing methods are applied to evaluate the performance of the proposed model under various conditions. Additionally, a visualization technique is employed to explain and interpret the model. Results: The proposed model achieves excellent prediction performance with an accuracy of 96.7%. Excluding absolute intensity information and retaining baseline noise did not affect the model's performance or interpretability. The proposed model trained on SonoVue data generalizes well to nanobubble data and vice versa. Visualization results indicate that the proposed model focuses on pulses with significant signals near the ultra-harmonic frequency. Conclusion: We demonstrate the feasibility of MIL in FUS BBB opening prediction. The proposed Transformer-based model exhibits outstanding performance, interpretability, and cross-agent generalization capability, providing a novel approach for FUS BBB opening prediction with clinical translation potential.

1 July 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HDHaixin Dai
Haixin Dai
WLWenjing Li
Wenjing Li
YWYan Wei
Yan Wei
LSLan Shen
Lan Shen
BCBingbing Cheng
Bingbing Cheng
Objective: The blood-brain barrier (BBB) poses a significant challenge for central nervous system drug delivery due to its selective permeability. Focused ultrasound (FUS) combined with bubble agents enables non-invasive, targeted BBB disruption. However, current methods for assessing efficacy and safety have limitations of high cost, low temporal resolution, or moderate predictive reliability, etc. Methods: This study proposes a novel gated attention-based model (GAB) for predicting BBB opening outcomes using time-domain acoustic signal clips. The GAB architecture incorporates an acoustic encoder to extract spectral and temporal features from short clips while modeling dependency between adjacent clips. A multi-way gated attention mechanism aggregates clip-level features, enhancing inter-class discriminability through adaptive selection. A task-specific loss function combining classification and similarity constraints further improves prediction by reducing redundancy in attention patterns. The outcomes of 174 FUS treatments were classified into three categories: BBB not opened, BBB opened without hemorrhage, and BBB opened with hemorrhage. Results: The GAB achieved superior performance in hemorrhage prediction (accuracy = 86.6 ± 4.9%, recall = 82.1 ± 10.9%, AUC = 0.894 ± 0.036, F1 score = 0.846 ± 0.062) compared to traditional cavitation dose-based methods and our previously developed frequency-domain deep learning models. Visualization of attention weights revealed that the model effectively distinguished broadband inertial cavitation signals (associated with hemorrhage) from ultra-harmonic stable cavitation signals (linked to safe BBB opening). Conclusion: The proposed method enhances temporal resolution, achieves superior predictive performance with interpretable cavitation features, and shows strong potential for real-time outcome prediction in FUS-mediated BBB disruption.