Rahul K. Mukherjee

Rahul K. Mukherjee

Auto-generated profile, based on publicly available information

Rahul K. Mukherjee

King's College London, London, UK

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
PDF file
JWJohn Whitaker
John Whitaker
JFJeffrey Fish
Jeffrey Fish
JHJames Harrison
James Harrison
HCHenry Chubb
Henry Chubb
SWSteven E. Williams
Steven E. Williams
MOMark D. O’nEill
Mark D. O’nEill
Background: The Lesion Index (LSI) is a proprietary algorithm from Abbott Medical combining contact force, radiofrequency application duration, and radiofrequency current. It can be displayed during ablation with the TactiCath contact force catheter. The LSI Index was designed to provide real-time lesion formation feedback and is hypothesized to estimate the lesion diameter. Methods and Results: Before ablation, animals underwent cardiac computed tomography to assess atrial tissue thickness. Ablation lines (n=2–3 per animal) were created in the right atrium of 7 Göttingen mini pigs with point lesions (25 W). Within each line of ablation, the catheter tip was moved a prescribed distance (D/mm) according to 1 of 3 strategies: D=LSI+0 mm; D=LSI+2 mm; or D=LSI+4 mm. Two weeks after ablation, serial sections of targeted atrial tissue were examined histologically to identify gaps in transmural ablation. LSI-guided lines had a lower incidence of histological gaps (4 gaps in 69 catheter moves, 5.8%) than LSI+2 mm lines (7 gaps in 33 catheter moves, 21.2%) and LSI+4 mm lines (15 gaps in 23 catheter moves, 65.2%, P <0.05 versus D=LSI). ΔLSI was calculated retrospectively as the distance between 2 adjacent lesions above the mean LSI of the 2 lesions. ΔLSI values of ≤1.5 were associated with no gaps in transmural ablation. Conclusions: In this model of chronic atrial ablation, delivery of uninterrupted transmural linear lesions may be facilitated by using LSI to guide catheter movement. When ΔLSI between adjacent lesions is ≤1.5 mm, no gaps in atrial linear lesions should be expected.

23 March 2018 in EP Europace
Verified
Journal Article
Open access
PDF file
RMRahul K Mukherjee
Rahul K Mukherjee
JWJohn Whitaker
John Whitaker
SWSteven E Williams
Steven E Williams
RRReza Razavi
Reza Razavi
MOMark D O’nEill
Mark D O’nEill
Catheter ablation has an important role in the management of patients with ventricular tachycardia (VT) but is limited by modest long-term success rates. Magnetic resonance imaging (MRI) can provide valuable anatomic and functional information as well as potentially improve identification of target sites for ablation. A major limitation of current MRI protocols is the spatial resolution required to identify the areas of tissue responsible for VT but recent developments have led to new strategies which may improve substrate assessment. Potential ways in which detailed information gained from MRI may be utilized during electrophysiology procedures include image integration or performing a procedure under real-time MRI guidance. Image integration allows pre-procedural magnetic resonance (MR) images to be registered with electroanatomical maps to help guide VT ablation and has shown promise in preliminary studies. However, multiple errors can arise during this process due to the registration technique used, changes in ventricular geometry between the time of MRI and the ablation procedure, respiratory and cardiac motion. As isthmus sites may only be a few millimetres wide, reducing these errors may be critical to improve outcomes in VT ablation. Real-time MR-guided intervention has emerged as an alternative solution to address the limitations of pre-acquired imaging to guide ablation. There is now a growing body of literature describing the feasibility, techniques, and potential applications of real-time MR-guided electrophysiology. We review whether real-time MR-guided intervention could be applied in the setting of VT ablation and the potential challenges that need to be overcome.

12 November 2022 in EP Europace
Verified
Journal Article
Open access
PDF file
SMSofia Monaci
Sofia Monaci
SQShuang Qian
Shuang Qian
KGKarli Gillette
Karli Gillette
EPEsther Puyol-Antón
Esther Puyol-Antón
RMRahul Mukherjee
Rahul Mukherjee
MBMartin Bishop
Martin Bishop
Aims: Existing strategies that identify post-infarct ventricular tachycardia (VT) ablation target either employ invasive electrophysiological (EP) mapping or non-invasive modalities utilizing the electrocardiogram (ECG). Their success relies on localizing sites critical to the maintenance of the clinical arrhythmia, not always recorded on the 12-lead ECG. Targeting the clinical VT by utilizing electrograms (EGM) recordings stored in implanted devices may aid ablation planning, enhancing safety and speed and potentially reducing the need of VT induction. In this context, we aim to develop a non-invasive computational-deep learning (DL) platform to localize VT exit sites from surface ECGs and implanted device intracardiac EGMs.Methods and results: A library of ECGs and EGMs from simulated paced beats and representative post-infarct VTs was generated across five torso models. Traces were used to train DL algorithms to localize VT sites of earliest systolic activation; first tested on simulated data and then on a clinically induced VT to show applicability of our platform in clinical settings. Localization performance was estimated via localization errors (LEs) against known VT exit sites from simulations or clinical ablation targets. Surface ECGs successfully localized post-infarct VTs from simulated data with mean LE = 9.61 ± 2.61 mm across torsos. VT localization was successfully achieved from implanted device intracardiac EGMs with mean LE = 13.10 ± 2.36 mm. Finally, the clinically induced VT localization was in agreement with the clinical ablation volume.Conclusion: The proposed framework may be utilized for direct localization of post-infarct VTs from surface ECGs and/or implanted device EGMs, or in conjunction with efficient, patient-specific modelling, enhancing safety and speed of ablation planning.

19 September 2018 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
GGGiulia Ginami
Giulia Ginami
KLKarina Lòpez
Karina Lòpez
RMRahul K. Mukherjee
Rahul K. Mukherjee
RNRadhouene Neji
Radhouene Neji
CMCamila Munoz
Camila Munoz
CPClaudia Prieto
Claudia Prieto
Purpose: Pre‐interventional assessment of atrial wall thickness (AWT) and of subject‐specific variations in the anatomy of the pulmonary veins may affect the success rate of RF ablation procedures for the treatment of atrial fibrillation (AF). This study introduces a novel non‐contrast enhanced 3D whole‐heart sequence providing simultaneous information on the cardiac anatomy—including both the arterial and the venous system—(bright‐blood volume) and AWT (black‐blood volume).Methods: The proposed MT‐prepared bright‐blood and black‐blood phase sensitive inversion recovery (PSIR) BOOST framework acquires 2 differently weighted bright‐blood volumes in an interleaved fashion. The 2 data sets are then combined in a PSIR‐like reconstruction to obtain a complementary black‐blood volume for atrial wall visualization. Image‐based navigation and non‐rigid respiratory motion correction are exploited for 100% scan efficiency and predictable acquisition time. The proposed approach was evaluated in 11 healthy subjects and 4 patients with AF scheduled for RF ablation.Results: Improved depiction of the cardiac venous system was obtained in comparison to a T2‐prepared BOOST implementation, and quantified AWT was shown to be in good agreement with previously reported measurements obtained in healthy subjects (right atrium AWT: 2.54 ± 0.87 mm, left atrium AWT: 2.51 ± 0.61 mm). Feasibility for MT‐prepared BOOST acquisitions in patients with AF was demonstrated.Conclusion: The proposed motion‐corrected MT‐prepared BOOST sequence provides simultaneous non‐contrast pulmonary vein depiction as well as black‐blood visualization of atrial walls. The proposed sequence has a large spectrum of potential clinical applications and further validation in patients is warranted.

12 February 2019 in Current Cardiovascular Imaging Reports
Verified
Journal Article
Open access
PDF file
RMRahul K. Mukherjee
Rahul K. Mukherjee
HCHenry Chubb
Henry Chubb
SRSébastien Roujol
Sébastien Roujol
RRReza Razavi
Reza Razavi
MOMark D. O’nEill
Mark D. O’nEill
Purpose of Review Theoretical benefits of real-time MRI guidance over conventional electrophysiology include contemporaneous 3D substrate assessment and accurate intra-procedural guidance and evaluation of ablation lesions. We review the unique challenges inherent to MRI-guided electrophysiology and how to translate the potential benefits in the treatment of cardiac arrhythmias. Recent Findings Over the last 5 years, there has been substantial progress, initially in animal models and more recently in clinical studies, to establish methods and develop workflows within the MR environment that resemble those of conventional electrophysiology laboratories. Real-time MRI-guided systems have been used to perform electroanatomic mapping and ablation in patients with atrial flutter, and there is interest in developing the technology to tackle more complex arrhythmias including atrial fibrillation and ventricular tachycardia. Summary Mainstream adoption of real-time MRI-guided electrophysiology will require demonstration of clinical benefit and will be aided by increased availability of devices suitable for use in the MRI environment.

19 September 2017 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
PDF file
SWSteven Williams
Steven Williams
NLNick Linton
Nick Linton
LOLouisa O'NEill
Louisa O'NEill
JHJames Harrison
James Harrison
JWJohn Whitaker
John Whitaker
MOMark O'NEill
Mark O'NEill
Introduction: Bipolar voltage is used during electroanatomic mapping to define abnormal myocardium, but the effect of activation rate on bipolar voltage is not known. We hypothesized that bipolar voltage may change in response to activation rate. By examining corresponding unipolar signals we sought to determine the mechanisms of such changes.Methods and results: LA extrastimulus mapping was performed during CS pacing in 10 patients undergoing first time paroxysmal atrial fibrillation ablation. Bipolar and unipolar electrograms were recorded using a PentaRay catheter (4‐4‐4 spacing) and indifferent IVC electrode, respectively. An S1S2 pacing protocol was delivered with extrastimulus coupling interval reducing from 350 to 200 milliseconds. At each recording site (119 ± 37 per LA), bipolar peak‐to‐peak voltage, unipolar peak to peak voltage and activation delay between unipole pairs was measured. Four patterns of bipolar voltage/extrastimulus coupling interval curves were seen: voltage attenuation with plateau voltage >1 mV (48 ± 15%) or 1 mV (17 ± 10%) or <1 mV (13 ± 8%). Electrograms showing bipolar voltage attenuation were associated with significantly greater unipolar voltage attenuation at low (25 ± 28 mV/s vs. 9 ± 11 mV/s) and high (23 ± 29 mV/s vs. 6 ± 12 mV/s) plateau voltage sites (P < 0.001). There was a small but significant increase in conduction delay between unipole pairs at sites showing bipolar voltage attenuation (P = 0.026).Conclusions: Bipolar electrogram voltage is dependent on activation rate at a significant proportion of sites. Changes in unipolar voltage and timing underlie these effects. These observations have important implications for use of voltage mapping to delineate abnormal atrial substrate.