31 January 2020 in Measurement Science and Technology
Irregular subaperture stitching interferometry (ISSI) is proposed for non-null optical freeform surface testing. Compared with circular and annular subapertures, irregular subapertures have a better performance in matching the locally resolvable interferograms due to the rotational asymmetry of freeform surfaces. A modified multi-aperture simultaneous reverse optimization reconstruction algorithm is employed for the subaperture stitching, allowing not only non-complementary subapertures but also no subaperture overlaps. Numerical simulations with error analyses display the accuracy of our method. Experiments showing the effectiveness of the ISSI are presented by testing a Φ20 mm biconic surface with cross-validation.
2 December 2019 in Applied Optics
In this paper, a high-spectral-resolution lidar (HSRL) for profiling atmospheric temperature from the ground to 10 km is proposed. A double Nd:YAG laser produces the transmitted laser at 532 nm. The backscattering lidar signal is passed through two different saturated iodine-vapor filters and thus obtains molecular scattering signals that can be employed to determine the temperature. A coaxial postposition transceiver is constructed with an off-axis aspheric reflective telescope (OART). The design of the transceiver and that of the OART are demonstrated. With this transceiver, the lidar blind zone where the overlap factor is zero can be reduced greatly, and accurate temperature measurement for full elevation can be achieved. The whole system is optimized with theoretical models based on geometrical optics and statistical error analyses. Monte Carlo simulations display the performance of the designed HSRL, showing that the all-day temperature retrieval error is better than 1.4 K from the ground to 10 km. The proposed HSRL is expected to provide more accurate atmospheric auxiliary parameters for the detection of aerosols’ optical characteristics.
1 April 2019 in Optics Communications
7 December 2020 in Measurement Science and Technology
A design method of non-null interferometers is proposed in this paper for measuring irregular surfaces such as optical aspherics, freeform surfaces and droplet surfaces. With system modeling and raytracing, the improved reverse optimization reconstruction method is employed to correct the retrace error and obtain the accurate shape of the test part with all frequency information. To simplify the model in the raytracing program, an imaging lens images the desired interferogram at a certain plane on the detector and, therefore, only the test arm needs to be modeled. The imaging error of an interferogram, which can be reduced by the partial compensation system (PCS), is analyzed, and the design of the PCS is also demonstrated. Two cases with different optical layouts show the feasibility and the versatility of our method.
11 March 2026 in Applied Optics
Addressing the challenges in quantitative 3D inspection of micro-to-nanoscale surface defects in optical components for high-energy laser systems, this paper proposes a novel, to our knowledge, inspection framework integrating bright-field and dark-field structured illumination microscopy (BDSIM) with deep learning-based 3D reconstruction. To mitigate the limitations of sparse point clouds and inherent noise caused by the low luminous flux in BDSIM imaging, we developed the Att-PU-Net model, building upon the point cloud upsampling network (PU-Net) architecture. This model incorporates a self-attention mechanism to enhance the contextual perception of local geometric abruptness and employs a multi-scale feature fusion strategy to preserve fine topological details. To ensure robust generalization from simulation to reality, a hybrid training strategy combining procedurally generated and real-world defect samples is adopted. Furthermore, a composite loss function integrating chamfer distance, repulsion loss, and curvature consistency constraints was designed to significantly improve point distribution uniformity and edge sharpness. Simulations and comparisons between Att-PU-Net and the marching cubes, contour filter algorithms demonstrate that Att-PU-Net achieves an optimal balance between geometric accuracy and uniformity (P2S: 0.5720 µm, NUC: 0.3230). Experimental validation on actual optical damage reveals a reconstruction accuracy of 0.6343 µm and a maximum error of only 0.79 µm in defect depth compared with white light interferometry (WLI), confirming the method’s effectiveness and reliability for high-precision 3D reconstruction of complex optical surface defects.