9 July 2016 in IEEE Antennas and Wireless Propagation Letters
This letter presents a novel Vivaldi antenna that can be used to the microwave measurement because of the character of near-field linear polarization plane-like waves. Compared to previous double-slot Vivaldi antenna with the same dimension, the proposed antenna's gain, standing-wave ratio, and radiation characteristics are both improved greatly above 12 GHz by the inclusion of the double-antipodal structure, corrugated edges, and a feature called “director.” Furthermore, the double-antipodal structure introduces a coupled E-field; this reduces total cross-polarization level of the antenna. The proposed antenna is measured, and results show that it has a 4.7- to 20-GHz impedance bandwidth and maintains 20-dB copolarization-to-cross-polarization ratio below 10 GHz and 15 dB below 16 GHz, and its gain increases from 10.3 to 14.8 dBi without a significant decline at high frequencies. Symmetrical feed network also results in better symmetry of the beam, especially in H-plane.
1 February 2018 in Review of Scientific Instruments
A microwave test system to measure the complex permittivity of solid and powder materials as a function of temperature has been developed. The system is based on a TM0n0 multi-mode cylindrical cavity with a slotting structure, which provides purer test modes compared to a traditional cavity. To ensure the safety, effectiveness, and longevity, heating and testing are carried out separately and the sample can move between two functional areas through an Alundum tube. Induction heating and a pneumatic platform are employed to, respectively, shorten the heating and cooling time of the sample. The single trigger function of the vector network analyzer is added to test software to suppress the drift of the resonance peak during testing. Complex permittivity is calculated by the rigorous field theoretical solution considering multilayer media loading. The variation of the cavity equivalent radius caused by the sample insertion holes is discussed in detail, and its influence to the test result is analyzed. The calibration method for the complex permittivity of the Alundum tube and quartz vial (for loading powder sample), which vary with the temperature, is given. The feasibility of the system has been verified by measuring different samples in a wide range of relative permittivity and loss tangent, and variable-temperature test results of fused quartz and SiO2 powder up to 1500 °C are compared with published data. The results indicate that the presented system is reliable and accurate. The stability of the system is verified by repeated and long-term tests, and error analysis is presented to estimate the error incurred due to the uncertainties in different error sources.
10 January 2018 in Microwave and Optical Technology Letters
1 September 2017 in Electronics Letters
A method aimed at dielectric parameters measurement of small samples using a coaxial re‐entrant cavity is proposed. After introducing grooves in the cavity structure to suppress parasitic modes, the operating frequency range has been broadened to 0.6–13 GHz for only one cavity. Compared to the traditional structure, the working bandwidth has expanded to 344% of the original one. The cavity perturbation technique is applied to detect the complex permittivity. The proposed method features two advantages over existing techniques, high sensitivity and more convenience for placing the sample.
19 January 2021 in IEEE Access
Magneto-electric materials with low loss have prospective applications in microwave systems as they enable miniaturization and broadband impedance matching. Two example applications are antennas and filters in sub-6G communication systems. Therefore, high-accuracy and wideband testing are critical for magneto-electric materials, whose complex permittivity and permeability are usually dependent on frequency. In this paper, the mutual interference between the electric and magnetic field within magneto-electric material samples was seriously considered. It was found that the results calculated with the original perturbation formula were overestimated when the sample size was not so small or higher-order modes are used, especially when the electric or magnetic field is perpendicular to the material under test. Two methods based on perturbation, namely the iteration method and the multi-state method are proposed to reduce the impact of the mutual interference, which have been proven to be direct and effective through theoretical analysis and experiments. Finally, several rod-shaped specimens processed from several standard dielectric materials (PTFE, fused silica, Al 2 O 3 ) and synthesized magneto-electric materials were measured in a fabricated cavity with a vector network analyzer. Experimental results show that the results obtained by the modified formula are more accurate than those obtained by the original formula, and are in good agreement with the data measured by other methods.
25 December 2023 in IEEE Transactions on Microwave Theory and Techniques
We propose a modified split-cylinder resonator (SCR) with open slits, which can suppress the majority of TM modes while lowering the quality factors of nonzero azimuthal mode TE modes compared with grooves or protrusions. Thereby, the interference of unwanted modes on the TE $_{0n1}$ measurements can be considerably reduced, which ultimately allows almost ten modes of TE $_{0n1}$ ( $n = 1$ –10) to be used for excellent broadband and high-accuracy measurement. In addition, we newly derive a rigorous analysis of the SCR with the coaxial-type slits based on the mode matching method in detail, along with a joint iterative algorithm for considering simultaneously flange and slit. Then the numerical validation results suggest the accuracy and validity of the scheme over a wide range of dielectric sample thicknesses and slit widths. Finally, two cavities operating at 10–40 GHz and 20–78 GHz, respectively, were machined for experiments, and the improved SCR method is further validated by measuring several specimens processed from well-known materials, such as PTFE and several commercial substrates. The results demonstrate that the proposed method can perform broadband and high-accuracy measurement of the complex permittivity for dielectric samples of different thicknesses. In addition, the main sources of measurement uncertainty are also analyzed.