BACKGROUND: GLP-1 (glucagon-like peptide-1) agonists have been proven beneficial in reducing the risk of and injury associated with several cardiovascular diseases. The efficacy in cardiopulmonary bypass-assisted cardiac surgery is unknown. This trial aimed to investigate the efficacy of an infusion of the GLP-1 agonist exenatide during and after open-heart surgery in reducing the risk of death and major organ failure. METHODS: Randomized, double-blinded, 2-by-2 factorial design, single-center clinical trial, also including liberal (FiO 2 of 100%) or restrictive (FiO 2 of 50%) oxygenation during and after bypass. The present article presents the results of the exenatide intervention. We included adult patients undergoing elective cardiopulmonary bypass-assisted coronary artery bypass grafting or aortic valve replacement. Patients were predominantly low risk. The intervention was an infusion of 17.4 µg of exenatide or placebo during cardiopulmonary bypass and the first hour after weaning thereof. The main outcome was time to a composite end point consisting of death, stroke, renal failure requiring dialysis, or new/worsening heart failure during follow-up. Secondary end points included occurrence of prespecified adverse events. RESULTS: A total of 1389 patients were included in the analyses. Within a follow-up period of a median of 5.9 years (min–max; 2.5–8.3 years), 170 (24%) patients in the exenatide group and 165 (24%) patients experienced a primary end point. We found no difference in time to the first event between patients randomized to FiO 2 50% versus FiO 2 100% (hazard ratio, 1.0 [95% CI, 0.83–1.3]; P =0.80). We found no significant difference in rates of adverse events between the 2 groups. CONCLUSIONS: Exenatide during cardiopulmonary bypass and weaning thereof did not significantly reduce the incidence of death, stroke, renal failure, or new/worsening heart failure in patients undergoing coronary artery bypass grafting and aortic valve replacement. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02673931.
4 February 2025 in Circulation: Cardiovascular Imaging
BACKGROUND: Infective endocarditis (IE) can be challenging to diagnose. Positron emission tomography/computed tomography (PET/CT) with 2-deoxy-2-[ 18 F]-fluoro- d -glucose ([ 18 F]FDG) is recommended as a diagnostic tool in the guidelines, but holds limitations. The aim of this study was to compare the tracer uptake between the novel [ 64 Cu]Cu-DOTATATE, which has low cardiac uptake and does not require fasting or dietary restrictions, and [ 18 F]FDG in patients with IE and examine the sensitivity and specificity. METHODS: The CuDOS study (Cu-Dotatate Positron Emissions Tomography in Infective Endocarditis) was a prospective study including 20 patients with IE (10 with prosthetic valve endocarditis and 10 with native valve endocarditis) and 20 controls. All participants underwent [ 64 Cu]Cu-DOTATATE and [ 18 F]FDG PET/CT. Scans were read blinded to clinical data. Tracer uptakes were measured as maximum standardized uptake values in each heart valve. Differences were tested with Wilcoxon rank tests. RESULTS: The median age of the cases and controls was 68 years (interquartile range [IQR], 55.0–75.5) and 61 years (IQR, 57.0–69.5), respectively. [ 64 Cu]Cu-DOTATATE uptake (median maximum standardized uptake value [IQR]) in patients with IE was higher than in controls (2.34 [1.40–3.23] versus 1.44 [1.21–1.60]; P =0.008), although this difference was mainly driven by prosthetic valve endocarditis cases (3.23 [2.02–3.86]; P <0.001) and not between native valve endocarditis cases and controls (1.51 [1.23–2.58]; P =0.428). The sensitivity of [ 64 Cu]Cu-DOTATATE and [ 18 F]FDG PET/CT in 20 cases versus 20 controls were equal, and the specificity was 90% and 75%, respectively. The analysis of prosthetic valve endocarditis versus the 20 controls showed equal sensitivity (80%), and a specificity of 90% and 75%, respectively ( P =0.38). In addition, a greater proportion of scans achieved diagnostic certainty with [ 64 Cu]Cu-DOTATATE PET/CT compared with [ 18 F]FDG PET/CT for native valve endocarditis, prosthetic valve endocarditis, and controls. CONCLUSIONS: [ 64 Cu]Cu-DOTATATE PET/CT showed uptake in the infected valve in patients with IE, and has major advantage as it does not require any preparation compared with [ 18 F]FDG. [ 64 Cu]Cu-DOTATATE had a numerically higher specificity than [ 18 F]FDG, although the difference was not statistically significant. Both tracers were limited in the detection of native valve endocarditis. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05432427. www.clinicaltrialsregister.eu ; Unique identifier: 2021-005501-27.
11 October 2023 in Scandinavian Cardiovascular Journal
The standard Conventional Cold Storage (CCS) during heart transplantation procurement is associated with time-dependent ischemic injury to the graft, which is a significant independent risk factor for post-transplant early morbidity and mortality - especially when cold ischemic time exceeds four hours. Since 2018, Rigshospitalet (Copenhagen, Denmark) has been utilising ex vivo perfusion (Organ Care System, OCS) in selected cases. The objective of this study was to compare the short-term clinical outcomes of patients transplanted with OCS compared to CCS. Methods: This retrospective single-centre study was based on consecutive patients undergoing a heart transplant between January 2018 and April 2021. Patients were selected for the OCS group when the cold ischemic time was expected to exceed four hours. The primary outcome measure was six-month event-free survival. Results: In total, 48 patients were included in the study; nine were transplanted with an OCS heart. The two groups had no significant differences in baseline characteristics. Six-month event-free survival was 77.8% [95% CI: 54.9-100%] in the OCS group and 79.5% [95% CI: 67.8-93.2%] in the CCS group (p = 0.91). While the OCS group had a median out-of-body time that was 183 min longer (p < 0.0001), the cold ischemic time was reduced by 51 min (p = 0.007). Conclusion: In a Scandinavian setting, our data confirms that utilising OCS in heart procurement allows for a longer out-of-body time and a reduced cold ischemic time without negatively affecting safety or early post-transplant outcomes.
Importance: Glucagon-like peptide-1 (GLP-1) agonists have been proven beneficial in reducing risk of and injury associated with several cardiovascular diseases. The efficacy in cardiopulmonary bypass (CPB)-assisted cardiac surgery is unknown. Objective: This trial aimed to investigate the efficacy of an infusion of the GLP-1 antagonist Exenatide during and after open heart surgery in reducing risk of death and major organ failure. Design: Randomized, double-blinded, 2-by-2 factorial design, clinical trial, also including liberal (FiO2 of 100%) or restrictive (FiO2 of 50%) oxygenation during and after bypass. The present paper presents the results of the Exenatide intervention. Setting: Single site, tertiary heart center. Participants: Adult patients undergoing elective cardiopulmonary bypass-assisted coronary artery bypass grafting and/or aortic valve replacement. Intervention: Infusion of 17.4 µg og Exenatide or placebo during cardiopulmonary bypass and the first hour after weaning thereof Main outcomes: The main outcome was time to a composite endpoint consisting of death, stroke, renal failure requiring dialysis, or new/worsening heart failure during follow-up. Secondary endpoints included occurrence of prespecified adverse events. Results: A total of 1389 patients were included in the analyses. Within a follow-up period of median of 5.9 years (min – max; 2.5 – 8.3 years), 170 patients (24%) in the Exenatide group and 165 patients (24%) experienced a primary endpoint. We found no difference in time to first event between patients randomized to FiO 2 50% versus FiO 2 100% (HR 1.0 [95%CI 0.83 – 1.3], p = 0.80). We found no significant difference in rates of adverse events between the two groups. Conclusions and Relevance: Exenatide during cardiopulmonary bypass and weaning thereof did not significantly reduce the incidence of death, stroke, renal failure, or new/worsening heart failure in patients undergoing coronary artery bypass grafting and/or aortic valve replacement. Trial registration: Danish Medicines Agency: Protocol no. HJE-PHARMA-001, EudraCT no. 2015-003050-41, 2 nd of October 2015 Local Ethics Committee “Videnskabsetisk komité C, Region Hovedstaden”: No. H-15010562 www.clinicaltrials.gov : ID no. NCT0267393 Key Points: Question: Is a single dose of Exenatide effectively reducing risk of death or major organ injury in patients undergoing cardiopulmonary bypass (CPB)-assisted cardiac surgery? Findings: 1400 patients undergoing coronary artery bypass grafting and/or aortic valve replacement were randomized to 17,4 µg of Exenatide or placebo during CPB and the first hour after weaning. The hazard ratio (95%CI) for time to the first occurring composite endpoint consisting of death, stroke, renal failure requiring dialysis, and new/worsening heart failure was 1.0 (0.83 – 1.3). Meaning: Exenatide infusion during CPB-assisted cardiac surgery does not improve outcomes.
Objectives. Temporary mechanical circulatory support (TMCS) has become a component in the therapeutic strategy for treatment of cardiogenic shock as a bridge-to-decision. TMCS can facilitate recovery of cardiopulmonary function, end-organ function, and potentially reduce the surgical risk of left ventricular assist device (LVAD) implantation. Despite the improvements of hemodynamics and end-organ function, post-LVAD operative morbidity might be increased in these high-risk patients. The aim of the study was to compare outcomes after Heartmate 3 (HM3) implantation in patients with and without TMCS prior to HM3 implant. Methods. In this retrospective cohort study of all HM3 patients in the period between November 2015 and October 2021, patients with and without prior TMCS were compared. Patients' demographics, baseline clinical characteristics, laboratory tests, intraoperative variables, postoperative outcomes, and adverse events were collected from patient records. Results. The TMCS group showed an improvement in hemodynamics prior to LVAD implantation. Median TMCS duration was 19.5 (14-26) days. However, the TMCS group were more coagulopathic, had more wound infections, neurological complications, and more patients were on dialysis compared with patient without TMCS prior to HM3 implantation. Survival four years after HM3 implantation was 80 and 82% in the TMCS (N = 22) and non-TMCS group (N = 41), respectively. Conclusion. Patients on TMCS had an acceptable short and long-term survival and comparable to patients receiving HM3 without prior TMCS. However, they had a more complicated postoperative course.