Gillian E. Clayton

Gillian E. Clayton

Auto-generated profile, based on publicly available information

Gillian E. Clayton

Centre for Research in Sustainable Agri-Food & Environment, School of Applied Sciences, College of Health, Science and Society, University of the West of England, Bristol, BS16 1QY, UK

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2021 in npj Clean Water
Verified
Journal Article
Open access
PDF file
GCGillian E. Clayton
Gillian E. Clayton
RTRobin M. S. Thorn
Robin M. S. Thorn
Darren ReynoldsDarren Reynolds
Darren Reynolds
Chlorine solutions are used extensively for the production of biologically safe drinking water. The capability of point-of-use [POU] drinking water treatment systems has gained interest in locations where centralised treatment systems and distribution networks are not practical. This study investigated the antimicrobial and anti-biofilm activity of three chlorine-based disinfectants (hypochlorite ions [OCl-], hypochlorous acid [HOCl] and electrochemically activated solutions [ECAS]) for use in POU drinking water applications. The relative antimicrobial activity was compared within bactericidal suspension assays (BS EN 1040 and BS EN 1276) using Escherichia coli. The anti-biofilm activity was compared utilising established sessile Pseudomonas aeruginosa within a Centre for Disease Control [CDC] biofilm reactor. HOCl exhibited the greatest antimicrobial activity against planktonic E. coli at >50 mg L−1 free chlorine, in the presence of organic loading (bovine serum albumen). However, ECAS exhibited significantly greater anti-biofilm activity compared to OCl- and HOCl against P. aeruginosa biofilms at ≥50 mg L−1 free chlorine. Based on this evidence disinfectants where HOCl is the dominant chlorine species (HOCl and ECAS) would be appropriate alternative chlorine-based disinfectants for POU drinking water applications.

22 March 2019 in Frontiers in Environmental Science
Verified
Journal Article
Open access
PDF file
GCGillian E. Clayton
Gillian E. Clayton
RTRobin M. S. Thorn
Robin M. S. Thorn
Darren ReynoldsDarren Reynolds
Darren Reynolds
Point-of-use (POU) drinking water treatment systems provide solutions for communities where centralized facilities are unavailable. Effective POU systems treat and reduce the number of pathogens in POU water supplies often employing disinfection. Chlorine disinfection results in the formation of disinfection by-products (DBPs), such as trihalomethanes (THMs), through the reaction of chlorine with natural organic matter (NOM) over time. Although THMs are known to be harmful to human health, little is known about their production within POU systems. This study compares the disinfectants; Electrochemically Activated Solutions (ECAS), hypochlorous acid (HOCl), and sodium hypochlorite (NaOCl), with respect to their potential to produce THMs within POU drinking water systems. Headspace solid-phase microextraction (HS-SPME) gas chromatography mass spectrometry (GC-MS) was utilized to quantify THMs in treated water samples containing NOM (Suwannee River humic acid, 4 mg L−1). All disinfection treatments were matched to free chlorine concentrations of 1, 3, and 5 mg L−1, using reaction times of 1, 5, and 10 min. THMs were produced at free chlorine concentrations of 5 mg L−1 and at reaction times of 5 and 10 min for all disinfectants. ECAS or HOCl, resulted in the formation of significantly lower total THM concentrations across all reaction times and free chlorine concentrations, compared to NaOCl. ECAS can be generated at the POU requiring only water, salt and energy for production, and this study demonstrates that its use results in reduced formation of THMs, compared with NaOCl. Further work is required to replicate these findings within scaled-up POU water treatment systems.

16 August 2023 in Journal of Global Health Reports
Verified
Journal Article
Open access
PDF file
FMFelicity V Mehendale
Felicity V Mehendale
GCGillian Clayton
Gillian Clayton
KHKate M Homyer
Kate M Homyer
Darren ReynoldsDarren Reynolds
Darren Reynolds
Disinfection is a mainstay of infection prevention, the importance of which was highlighted throughout the SARS-CoV-2 pandemic. There is frequent misuse of terminology surrounding chlorine solutions in the literature. This leads not only to confusion but has potentially dangerous outcomes, as inappropriate mixing of chlorine solutions with other disinfectants or cleaning solutions can lead to the release of chlorine gas. This article provides a resource for accurate terminology surrounding chlorine-based disinfection and clarifies some of the key inaccuracies, including the pH-dependent nature of chlorine species distribution of hypochlorous acid (HOCl) (neutral/acidic chlorine solution) and hypochlorite (OCl-) (alkaline chlorine solution). Misuse and misunderstanding of chlorine solutions and the terminology used can be harmful therefore this is an essential resource for those utilising chlorine as a disinfectant.

1 August 2019 in Journal of Water Process Engineering
Verified
Journal Article
Open access
GCGillian E. Clayton
Gillian E. Clayton
RTRobin Thorn
Robin Thorn
DRDarren M. Reynolds
Darren M. Reynolds

25 February 2025 in Water Research
Verified
Journal Article
Open access
GCGillian E. Clayton
Gillian E. Clayton
Laura RichardsLaura Richards
Laura Richards
Bethany FoxBethany Fox
Bethany Fox
RTRobin Thorn
Robin Thorn
MBMichael J. Bowes
Michael J. Bowes
Darren ReynoldsDarren Reynolds
Darren Reynolds
The Ganga River (known internationally as the Ganges) is one of the world's most prominent rivers, running from the Himalayas to the Bay of Bengal and supporting the livelihoods of > 40 % of India's 1.4 billion population. The Ganga River is regionally and globally important, supporting agriculture and industry, yet faces potentially detrimental water quality challenges arising from runoff and discharge from increasing urbanization, industry and agriculture. A ∼ 2700 km longitudinal survey of the nutrient and microbial water quality, including phytoplankton composition, of the Ganga River was undertaken in November 2019. The aim was to investigate if and how anthropogenic activities (e.g. urbanisation, industry, and agriculture) and tributary convergence (potentially reflecting both human activity and flow influences) affect and shift physicochemical, nutrient, and microbial water quality parameters along the river continuum. Segmented regression identified four zones of distinct nutrient/microbial characteristics along the Ganga River, with breakpoints located near Kanpur, Varanasi and downstream of the Farakka Barage, at distances of ∼ 1020, ∼ 1500 and ∼ 2350 km downstream from the Himalayan Ganga source. Population density, land use and urban cover were associated with selected water quality parameters in parts of the catchment, with elevated nutrient, microbial and chemical concentrations likely associated with agriculture, industry, and sewage inputs. Some urban areas (e.g. Kanpur and Varanasi), converging tributaries (e.g. Yamuna and Varuna) and barrages (e.g. Farakka) were associated with changes in nutrient availability, microbial activity/abundance and modelled discharge, likely driving apparent water quality changes in the relevant locations. Downstream shifts in nutrient and microbial water quality parameters were observed throughout the ∼ 2700 km Ganga River continuum. This information can help prioritize locations for targeted monitoring and/or remediation interventions and has illustrated an approach to quantify impacts of anthropogenic inputs on major river systems, such as the Ganga River.

4 April 2024 in PLOS Water
Verified
Journal Article
Open access
PDF file
GCGillian E. Clayton
Gillian E. Clayton
RTRobin M. S. Thorn
Robin M. S. Thorn
BFBethany G. Fox
Bethany G. Fox
Darren ReynoldsDarren Reynolds
Darren Reynolds
Two billion people lack access to safely managed drinking water services, many of these are in low/middle income countries where centralised systems are impractical. Decentralised point-of-use drinking water treatment systems offer alternative solutions in remote or resource constrained settings. The main aim of this study was to assess the long-term (3 year) operation and performance of a point-of-use drinking water treatment system (POU-DWTS). A biologically contaminated urban drainage pond was used as a water source and the quality of the produced drinking water was assessed over two independent trials. The decentralised POU-DWTS combined ultrafiltration membranes with disinfection from electrochemically generated hypochlorous acid (HOCl). The operational parameters, such as flow rate, free available chlorine and transmembrane pressure, were monitored in real-time and recorded via a remote monitoring system. Water quality from the source and treated water was assessed over two trial periods within the 3-year operational trial: an 11-week period at the start and a 22-week trial at the end. All water samples were assessed for a range of basic, chemical, microbiological and metal water quality parameters. The results demonstrate that the decentralised POU-DWTS is capable of continuously producing high quality drinking water when HOCl is continuously used to dose water prior to entering the ultrafiltration [UF] membranes. Over the 3-year operational study, the continuous dosing of HOCl pre-UF membranes resulted in stable permeability, indicating no occurrences of irreversible biofouling within the UF membranes and that good membrane ‘health’ was maintained throughout. As such, there was no need to replace the UF membranes nor undertake acid/alkaline chemical cleans at any point throughput the three-year study. The POU-DWTS continuously produced high quality drinking water, resulting in 6453 m3 of drinking water produced over the trial period, that met international water quality standards, at a community scale within the location studied.