Goran Pavić

Goran Pavić

Auto-generated profile, based on publicly available information

Goran Pavić

Laboratoire Vibrations-Acoustique, Institut National des Sciences Appliquées de Lyon, 69621 Villeurbanne, France

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

4 April 2017 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
GPG. Pavić
G. Pavić
FCF. Chevillotte
F. Chevillotte
JHJ. Heraud
J. Heraud
An outline is made of physical behaviour of water - filled large pipes. The fluid-wall coupling, the key factor governing the pipe dynamics, is discussed in some detail. Different circumferential pipe modes and the associated cut-on frequencies are addressed from a theoretical as well as practical point of view. Major attention is paid to the breathing mode in view of its importance regarding main dynamic phenomena, such as water hammer. Selected measurement results done at EDF are presented to demonstrate how an external, non-intrusive sensor can detect pressure pulsations of the breathing mode in a pressure pipe. Differences in the pressure measurement using intrusive and non-intrusive sensors reveal the full complexity of large-diameter pipe dynamics.

1 June 2010 in Journal of Vibration and Acoustics
Verified
Journal Article
Closed access
PDF file
GPGoran Pavić
Goran Pavić
AEAndrew S. Elliott
Andrew S. Elliott
A method has been developed to characterize a vibration source when coupled via resilient mounts to a receiver structure. This two-step measurement procedure can deliver the mobility and free velocity of a source, together with the mobility of the receiver to which it is connected, without decoupling the two structures. The method is feasible in a practical sense as it does not require any knowledge of mount properties. This is a major advantage as mount properties can deviate from their stated specifications through tolerances, and furthermore, the properties may change when loaded in the coupled-state. A benchmark test is used as a validation reference for the method where the properties of the resilient mounts are required and are assumed as known but not completely certain. The comparison of the benchmark and the principal method is used to illustrate the benefits of the latter given a small error in the supposedly known mount properties. In this first part of the paper, the principles of the two methods are illustrated using a simple demonstrator example while in the second part the feasibility of the method is further examined by virtual experiment involving two built-up plates resiliently connected at several points.

11 October 2018 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
GPGoran Pavić
Goran Pavić
LDLiangfen Du
Liangfen Du

1 January 2018 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
GPGoran Pavić
Goran Pavić
The performance of different solutions to global vibration reduction using external damping is discussed. The solutions are either uneven distribution of structural damping or use of vibration absorbers. To this end, a comparative study is carried out, built on simple analytical models. It is shown that a well‐chosen solution can produce a substantial reduction of global vibration level. It is further shown that the overall damping effect critically depends on the mutual interaction between the applied damping device and the damped structure. Qualitative guidelines are provided about the selection of appropriate parameters that affect damping performance.

1 June 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
FCFabien Chevillotte
Fabien Chevillotte
GPGoran Pavić
Goran Pavić
GDGuillaume JR Dubois
Guillaume JR Dubois
GPGilles Proulx
Gilles Proulx
MGMartin Gagnon
Martin Gagnon
This paper focuses on the analysis of dynamic pressure fluctuations in hydro-electric power plants. Pressure fluctuations are usually measured with remote sensors and the dynamic behaviour of the remote tubing line modifies the readings of dynamic pressure and thus introduces a bias. A method to characterize the remote tubing line and to correct the actual pressure is proposed. The corrected measurements are compared with those obtained using intrusive flush-mounted sensors as well as non-intrusive sensors (PVDF wires and strain gauges). Then, the technique to separate the forward and backward components of the obtained pressure pulsations is outlined. It is further shown how the pulsations and the hoop stresses can be reconstructed along the penstock. Finally, measurements carried out in a hydropower plant are presented to demonstrate the proposed techniques applicability for the analysis of dynamic pressure in a penstock. The results show that a pressure profile can be mapped along the penstock length which allows a comparison with the direct pressure sensor measurements.