Torpor is an energy-conserving state in which animals dramatically decrease their metabolic rate and body temperature to survive harsh environmental conditions. Here, we report the noninvasive, precise and safe induction of a torpor-like hypothermic and hypometabolic state in rodents by remote transcranial ultrasound stimulation at the hypothalamus preoptic area (POA). We achieve a long-lasting (>24 h) torpor-like state in mice via closed-loop feedback control of ultrasound stimulation with automated detection of body temperature. Ultrasound-induced hypothermia and hypometabolism (UIH) is triggered by activation of POA neurons, involves the dorsomedial hypothalamus as a downstream brain region and subsequent inhibition of thermogenic brown adipose tissue. Single-nucleus RNA-sequencing of POA neurons reveals TRPM2 as an ultrasound-sensitive ion channel, the knockdown of which suppresses UIH. We also demonstrate that UIH is feasible in a non-torpid animal, the rat. Our findings establish UIH as a promising technology for the noninvasive and safe induction of a torpor-like state.
The static magnetic field of an MRI scanner was found to dampen microbubble cavitation activity and decrease the focused ultrasound combined with microbubble-mediated blood-brain barrier opening. Background Focused ultrasound combined with microbubbles has been used in clinical studies for blood-brain barrier (BBB) opening in conjunction with MRI. However, the impact of the static magnetic ...
MRI-guided focused ultrasound combined with microbubbles has been used in clinical studies for blood-brain barrier (BBB) opening. However, the impact of the static magnetic field generated by an MRI scanner on the BBB opening outcome has not been evaluated. The objective of this study was to determine the relationship of the static magnetic field of an MRI scanner on focused ultrasound combined with microbubble-induced BBB opening. Mice were divided into four groups which were sonicated by FUS in different static magnetic fields B0 (∼0T, 1.5T, 3.0T, and 4.7T) with all other experimental parameters kept the same. Microbubble cavitation activity was monitored by passive cavitation detection during FUS after microbubble injection. After sonication, contrast-enhanced T1-weighted MRI and Evans blue were used to evaluate the BBBO outcome. The microbubble cavitation dose decreased by an average of 2.1 dB at 1.5T (P = 0.05), 2.9 dB at 3.0T (Pi = 0.01), and 3.0 dB at 4.7T (P = 0.01) compared with that outside the magnetic field. It also decreased Evans blue trans-BBB delivery 1.4-fold at1.5T (P = 0.009), 1.6-fold at 3.0T (P < 0.001), and 1.9-fold at 4.7T (P < 0.001). These findings demonstrated that static magnetic fields dampened microbubble cavitation and decreased trans-BBB delivery by FUS.