Christine Cannataci

Christine Cannataci

Auto-generated profile, based on publicly available information

Christine Cannataci

Medical Imaging Department, Mater Dei Hospital, Msida, Malta

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2020 in La radiologia medica
Verified
Journal Article
Closed access
PDF file
RMRoberto Miraglia
Roberto Miraglia
LMLuigi Maruzzelli
Luigi Maruzzelli
CCChristine Cannataci
Christine Cannataci
RGRoberta Gerasia
Roberta Gerasia
GMGiuseppe Mamone
Giuseppe Mamone
ALAngelo Luca
Angelo Luca

1 December 2020 in Radiology
Verified
Journal Article
Closed access
SCSettimo Caruso
Settimo Caruso
CCChristine Cannataci
Christine Cannataci
GRGiuseppe Romano
Giuseppe Romano
History A 46-year-old woman was admitted to our hospital with decompensated congestive heart failure and pericardial effusion diagnosed on echocardiography. She had no family history of sudden cardiac death. She was born at term and experienced no cardiac events until 4 years of age, at which point she was hospitalized because of three syncopal episodes that were not related to exercise. Over the next 10 years, she experienced two additional episodes of syncope not related to exercise. She had another hospital admission at 12 years of age. Clinical examination did not reveal cyanosis or clubbing, peripheral pulses were normal, and blood pressure was 90/60 mmHg. Her venous pressure was elevated, but the liver was not enlarged, and the lung fields were clear. Electrocardiography showed sinus rhythm, right bundle branch block, T-wave inversion in V6, and evidence of right atrial dilatation. Two-dimensional echocardiography showed normal intracardiac connections, with the tricuspid valve in the normal position and normal size of the left atrium and left ventricle with a normal ejection fraction. The right ventricle was dilated without evidence of right ventricular outflow tract obstruction. Implantation of an implantable cardioverter-defibrillator was considered but was ultimately contraindicated because of right ventricle anatomy. Thus, the patient received conservative care and was started on digoxin and diuretics. At 32 years of age, she experienced an episode of atrial flutter that was treated with electrical cardioversion. As stated earlier, at 46 years of age, she was admitted to our hospital with decompensated heart failure to be evaluated for a heart transplant. She underwent electrocardiography, echocardiography, cardiac MRI with and without administration of contrast media, and non-cardiac-gated multidetector CT with and without contrast media to rule out pulmonary embolism. The following quantitative results were obtained with MRI: Left ventricular end-diastolic volume (LVDV) was 40 mL (LVDV per body surface area [BSA], 25 mL/m(2)); left ventricular end-systolic volume (LVSV), 21 mL (LVSV/BSA, 13 mL/m(2)); stroke volume (SV), 19 mL (SV/BSA, 12 mL/m(2)); and ejection fraction, 47%. Right ventricular end-diastolic volume (RVDV) was 262 mL (RVDV/BSA, 164 mL/m(2)); right ventricular end-systolic volume (RVSV), 198 mL (RVSV/BSA, 124 mL/m(2)); stroke volume (SV), 64 mL (SV/BSA, 40 mL/m(2)); and ejection fraction, 24%. Phase contrast sequences in the aorta and pulmonary artery showed systemic output of 20 mL and pulmonary output of 18 mL. Tricuspid regurgitation was massive (46 mL) (Figs 1-4).

1 April 2021 in Radiology
Verified
Journal Article
Closed access
SCSettimo Caruso
Settimo Caruso
CCChristine Cannataci
Christine Cannataci
GRGiuseppe Romano
Giuseppe Romano
History A 46-year-old woman was admitted to our hospital with decompensated congestive heart failure and pericardial effusion diagnosed at echocardiography. She had no family history of sudden cardiac death. She was born at term and experienced no cardiac events until 4 years of age, at which point she was hospitalized because of three syncopal episodes that were not related to exercise. Over the next 10 years, she experienced two additional episodes of syncope not related to exercise. She had another hospital admission at 12 years of age. Clinical examination did not reveal cyanosis or clubbing, peripheral pulses were normal, and blood pressure was 90/60 mmHg. Her venous pressure was elevated, but the liver was not enlarged, and the lung fields were clear. Electrocardiography showed sinus rhythm, right bundle branch block, T-wave inversion in V6, and evidence of right atrial dilatation. Two-dimensional echocardiography showed normal intracardiac connections, with the tricuspid valve in the normal position and normal size of the left atrium and left ventricle with a normal ejection fraction. The right ventricle (RV) was dilated, without evidence of RV outflow tract obstruction. Implantation of an implantable cardioverter-defibrillator was considered but was ultimately contraindicated because of RV anatomy. Thus, the patient received conservative care and was started on digoxin and diuretics. At 32 years of age, she experienced an episode of atrial flutter that was treated with electrical cardioversion. As stated earlier, at 46 years of age, she was admitted to our hospital with decompensated heart failure to be evaluated for a heart transplant. She underwent electrocardiography, echocardiography, cardiac MRI with and without administration of contrast media, and non–cardiac-gated multidetector CT (MDCT) with and without contrast media to rule out pulmonary embolism. The following quantitative results were obtained with MRI: Left ventricular end-diastolic volume (LVDV) was 40 mL (LVDV per body surface area [BSA], 25 mL/m2); left ventricular end-systolic volume (LVSV), 21 mL (LVSV/BSA, 13 mL/m2); left ventricular stroke volume (SV), 19 mL (SV/BSA, 12 mL/m2); and left ventricular ejection fraction, 47%. RV end-diastolic volume (RVDV) was 262 mL (RVDV/BSA, 164 mL/m2); RV end-systolic volume (RVSV), 198 mL (RVSV/BSA, 124 mL/m2); RV stroke volume (SV), 64 mL (SV/BSA, 40 mL/m2); and RV ejection fraction, 24%. Phase contrast sequences in the aorta and pulmonary artery showed systemic output of 20 mL and pulmonary output of 18 mL. Tricuspid regurgitation was massive (46 mL).

1 January 2022 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
RGRoberta Gerasia
Roberta Gerasia
CCC Cannataci
C Cannataci
GGG S Gallo
G S Gallo
CTC Tafaro
C Tafaro
LML Maruzzelli
L Maruzzelli
RMRoberto Miraglia
Roberto Miraglia
The aim of this work was to establish local diagnostic reference levels (DRLs) for retrograde wedge portography (RWP) performed on pediatric patients assessing the usefulness of radiation dose monitoring software in the establishing process. Between September 2016 and April 2020, 66 consecutive RWP were performed at a transplantation institute and were included in our study. Patients were divided in three groups according to age: n = 25 infants, n = 20 middle childhood and n = 21 early adolescence. The third quartile of both Air Kerma at the reference point (Ka,r) and air kerma-area product (PKA) were evaluated to establish local DRLs (lDRLs). In addition, to control high Ka,r levels during procedures, the software notified to operators if Ka,r exceeded the dose ‘alert’ threshold set at 2 Gy. lDRLs were established for all three groups using PKA and Ka,r: infant group: 5.6 Gy.cm 2 and 0.034 Gy; middle childhood: 6.4 Gy.cm2 and 0.018 Gy and early adolescence: 12.8 Gy.cm2 and 0.059 Gy. The dose threshold ‘alert’ was never encountered (alert quota: 0%). The dose monitoring system supports the feasibility of accurate and easier lDRLs’ establishment.

17 February 2023 in Heart, Lung and Circulation
Verified
Journal Article
Closed access
GGGiuseppe S. Gallo
Giuseppe S. Gallo
CCCalogero Caruso
Calogero Caruso
EIErica Iannazzo
Erica Iannazzo
CCChristine Cannataci
Christine Cannataci
RGRoberta Gerasia
Roberta Gerasia
RMRoberto Miraglia
Roberto Miraglia