Eamonn Clarke

Eamonn Clarke

Auto-generated profile, based on publicly available information

Eamonn Clarke

Department of Chemistry, University of Utah, Salt Lake City, Utah 84112, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

6 April 2022 in Electroanalysis
Verified
Journal Article
Closed access
JGJohn‐Bruce D. Green
John‐Bruce D. Green
ECEamonn Clarke
Eamonn Clarke
MPMarc D. Porter
Marc D. Porter
CMChristie A. McDermott
Christie A. McDermott
MMMark T. McDermott
Mark T. McDermott
ABAdam Johan Bergren
Adam Johan Bergren

23 January 2025 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
ECEamonn Clarke
Eamonn Clarke
MPMarc D. Porter
Marc D. Porter
A nitrogen blowdown evaporator built with widely-available materials and techniques is described, accompanied by plans and detailed instructions for assembly. We show that the apparatus operates without causing contamination or sample loss.

17 July 2024 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
CLChristopher Lambert
Christopher Lambert
ECEamonn Clarke
Eamonn Clarke
DPDhruv Patel
Dhruv Patel
LLLars Bjorn Laurentius
Lars Bjorn Laurentius
BGBruce Gale
Bruce Gale
MPMarc D. Porter
Marc D. Porter
Tuberculosis (TB) represents a major public health threat, with millions of new cases reported worldwide each year. A major hurdle to curtailing the spread of this disease is the need for low-cost, point-of-care (PoC) diagnostics. Mannose-capped lipoarabinomannan, a significant component of the Mycobacterium tuberculosis bacillus, has been heavily studied as a biomarker for TB, but with little success due to its complexation with endogenous components of body fluids in a manner that sterically interferes with its detection by ELISA and other immunoassays. Recent work by our group and others has shown that complexation can be disrupted with protein-denaturing protocols. By way of followup, we recently described an enzymatic digestion (Proteinase K) sample pretreatment that enables quantitative recovery of ManLAM spiked into healthy human control serum. Herein, we report on the transfer of our benchtop sample pretreatment methodology to an automated microfluidic platform. We show that this platform can be configured to: (1) carry out the pretreatment process with very little user interaction and, (2) yield recoveries for ManLAm spiked into control serum which are statistically indistinguishable from those achieved by the benchtop process. Plans to integrate this device with a portable sample reader as a possible basis for a PoC TB diagnostic system and analyze patient samples are briefly discussed.

26 August 2025 in Applied Spectroscopy
Verified
Journal Article
Closed access
ECEamonn Clarke
Eamonn Clarke
SSSpencer Sonntag
Spencer Sonntag
CKCarol Korzeniewski
Carol Korzeniewski
MPMarc D. Porter
Marc D. Porter
This paper reports on the application of infrared external reflection spectroscopy (IR-ERS) to the characterization of small surface area addresses prepared on smooth gold surfaces after modification for use as capture substrates in sandwich immunoassays based on surface-enhanced Raman scattering (SERS). Most of the past work with IR-ERS on analyzing coatings formed on highly reflective metals utilized relatively large area samples (e.g., 76 × 25 mm glass microscope slides and ∼51 mm diameter silicon wafers) to accommodate the large size of the elliptical IR beam reflected off the metal surface at grazing angles of incidence. Our interest in employing assay-sized (3 mm diameter) addresses for IR-ERS measurements arises from the need to minimize the consumption, and, thereby, the expense of rare biological reagents like the antibodies under development for immunoassays to detect tuberculosis. The obvious approach to achieving this goal would be to utilize the spatial resolution and sample scanning capabilities of Fourier transform infrared (FT-IR) microscopes. We, however, opted to re-examine the physical optics and geometric layout of the measurement through an analysis of the strength of the mean square electric field at the sample/substrate interface as a function of angle of incidence. These findings suggested that, given the high light throughput and low noise levels of today’s FT-IR spectrometers, it may be possible to perform these measurements simply by collecting spectra at a lower angle of incidence when using the optical layout of a standard IR-ERS experiment. Herein, we report both the theoretical analysis and experimental results that demonstrate it is possible to obtain useful spectra from much smaller samples than those traditionally used, e.g., those employed in our SERS-based immunoassays, simply by decreasing the angle at which the IR beam is incident on the sample surface. We also demonstrate that these types of samples can be analyzed by constructing a small jig that allows for the careful positioning of the sample in the IR beam, rather than by extensively modifying the optics of the IR-ERS accessory.