JongGab Jo

JongGab Jo

Auto-generated profile, based on publicly available information

JongGab Jo

Department of Nuclear Engineering, Seoul National University 1 , Seoul 08826, South Korea

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
JJJongGab Jo
JongGab Jo
HLH. Y. Lee
H. Y. Lee
SKS. C. Kim
S. C. Kim
SKS. H. Kim
S. H. Kim
YAY. H. An
Y. H. An
YHY. S. Hwang
Y. S. Hwang
Pre-ionization experiments with pure toroidal field have been carried out in VEST (Versatile Experiment Spherical Torus) to investigate the feasibility of direct XB mode conversion from perpendicular LFS (Low Field Side) injection for efficient pre-ionization. Pre-ionization plasmas are studied by measuring the electron density and temperature profiles with respect to microwave power and toroidal field strength, and 2D full wave cold plasma simulation using the COMSOL Multiphysics is performed for the comparison. It is experimentally figured out that exceeding the threshold microwave power (>3 kW), the parametric decay and localized collisional heating is observed near the UHR (Upper Hybrid Resonance), and the efficient XB mode conversion can be achieved in both short density scale length (Ln) and magnetic scale length (LB) region positioned at outboard and inboard sides, respectively. From the 2D full wave simulations, the reflection and tunneling of X-wave near the R-cutoff layer according to the measured electron density profiles are analyzed with electric field polarization and power flow. Threshold electric field and wave power density for parametric decay are evaluated at least more than 4.8 × 104 V/m and 100 W/cm2, respectively. This study shows that efficient pre-ionization schemes using direct XB mode conversion can be realized by considering the key factors such as Ln, LB, and transmitted wave power at the UHR. Application to Ohmic start-up experiment is carried out to confirm the effect of the pre-ionization schemes on tokamak plasma start-up in VEST.

1 August 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
JJJongGab Jo
JongGab Jo
JWJ. Wang
J. Wang
HLH. W. Lee
H. W. Lee
SKS. C. Kim
S. C. Kim
BLB. J. Lee
B. J. Lee
YHY. S. Hwang
Y. S. Hwang
The fast wave branch in lower hybrid resonance frequency range, especially higher than 2 ω l h , has been proposed for the central or off-axis electron heating and current drive in higher density plasmas than the slow wave scheme. With a higher cutoff density for launching, efficient coupling between the antenna and plasma would be a priority issue for feasibility. The fast wave coupling characteristics with the wave frequency, gap size, and electron density profile of the Versatile Experiment Spherical Torus (VEST) device are investigated using a commercial full wave FEM solver, COMSOL. Maximum coupling between combline antenna and plasma is expected to be at ∼500 MHz with n ∥ ∼ 4.5 . The coupled power ranges from 90% to 60% in the gap size between 0.5 cm and 1.5 cm. The relative power fraction of the fast wave is larger than 80% at these conditions. The propagation and coupling power of the fast wave is crucially dependent on the plasma density window by launching and confluence densities. Initial experimental result with low power shows that measured coupling efficiency starts to increase as electron density in front of antenna attains the level of cutoff density for the fast wave propagation. It varies from 30% to 90% with the edge density evolution, which is consistent with the coupling simulation using the measured edge density profile. Coupling simulation verified in this study will make it possible to predict and analyze the coupling characteristics of future lower hybrid fast wave experiments.

4 January 2022 in Nuclear Fusion
Verified
Journal Article
Open access
JKJ. Kim
J. Kim
JKJ. Kang
J. Kang
TRT. Rhee
T. Rhee
JJJ. Jo
J. Jo
HHH. Han
H. Han
CCC.Z. Cheng
C.Z. Cheng
Advanced operation scenarios such as high poloidal beta (β P) or high q min are promising concepts to achieve the steady-state high-performance fusion plasmas. However, those scenarios are prone to substantial Alfvénic activity, causing fast-ion transport and losses. Recent experiments with the advanced operation scenario on KSTAR tokamak have shown that the electron cyclotron current drive (ECCD) is able to mitigate and suppress the beam-ion driven toroidal Alfvén eigenmodes (TAEs) for over several tens of global energy confinement time. Co-current directional intermediate off-axis ECCD lowers the central safety factor slightly and tilts the central q-profile shape so that the continuum damping in the core region increases. Besides, the rise of central plasma pressure and increased thermal-ion Landau damping contribute to TAE stabilization. While the TAEs are suppressed, neutron emission rate and total stored energy increase by approximately 45% and 25%, respectively. Fast-ion transport estimated by TRANSP calculations approaches the classical level during the TAE suppression period. Substantial reduction in fast-ion loss and neutron deficit is also observed. Enhancement of fast-ion confinement by suppressing the TAEs leads to an increase of non-inductive current fraction and will benefit the sustainment of the long-pulse high-performance discharges.

1 June 2022 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SHSung-Ryul Huh
Sung-Ryul Huh
BJBong-Ki Jung
Bong-Ki Jung
JJJong-Gab Jo
Jong-Gab Jo
MPMin Park
Min Park
SJSeung Ho Jeong
Seung Ho Jeong
DCDae-Sik Chang
Dae-Sik Chang
The Korea Atomic Energy Research Institute has recently proposed and developed a novel cesium-free negative hydrogen/deuterium ion source system based on two pulsed plasma sources for fusion and particle accelerator applications. The main feature of this ion source system is the use of both magnetic filters and plasma pulsing (also called the temporal filter). The system operates with two alternate pulsing sequences related to the respective plasma sources, thereby switching the plasmas in the after-glow state in an alternating manner. This study investigates the temporal behavior of deuterium negative ions in the system in a qualitative way by conducting a time-resolved measurement of laser photodetachment current commensurate with the negative ion density. In preliminary experiments, the current in the initial after-glow state remains higher than in the active-glow state identical to a steady-state continuous wave plasma, and the ratio reaches a maximum of about three times. This indicates that the pulsing gives highly efficient negative ion volume formation. Furthermore, it is observed that the time duration when the current is maintained at high values can be prolonged (or modulated) with the alternate dual pulsing, which is not possible with conventional single pulsing. These results provide a clue that the multi-pulsed ion source system may offer a continuous supply of negative ions at high densities and consequently become an alternative to cesium seeded ion sources.

3 February 2023 in Fusion Engineering and Design
Verified
Journal Article
Closed access
JJJongGab Jo
JongGab Jo
SKS.H. Kim
S.H. Kim

1 September 2021 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
JJJong Gab Jo
Jong Gab Jo
SJSeung Ho Jeong
Seung Ho Jeong
TKTae-Seong Kim
Tae-Seong Kim
SKS. H. Kim
S. H. Kim
MPMin Park
Min Park
SHSung-Ryul Huh
Sung-Ryul Huh
The optimization of 2.45 GHz microwave coupling in an electron cyclotron resonance (ECR) ion source is investigated through experiments and full wave simulation studies. The axial magnetic field profile and an impedance transformer are the two major factors affecting the optimum power coupling. Experimental observations have shown that the beam current density increases when the two ECR zones are located in the plasma chamber and when the first ECR zone is close to the RF entrance. A coupling study with various magnetic field profiles finds that the gap distance between the RF window and first ECR zone and the effective ECR zone width determines the coupling efficiency. Optimum power coupling is obtained under the condition of an appropriately slight gap distance comparable to the half width of the effective ECR zone. The extracted beam current density increases when the second ECR zone becomes closer to the plasma grid. With the optimized axial magnetic field profile, impedance transformers are designed in consideration of reflection coefficient with respect to the plasma density. The performance of the impedance transformers is experimentally evaluated in terms of the efficiency (mA/W) with the findings consistent with the results of a simulation. The highest beam current density (∼165 mA/cm2) in these experiments is achieved with the optimized axial magnetic profile and the impedance transformer.