Thomas L. Robl

Thomas L. Robl

Auto-generated profile, based on publicly available information

Thomas L. Robl

University of Kentucky Center for Applied Energy Research 1 , 2540 Research Park Dr., Lexington, KY 40511

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2022 in Cement and Concrete Composites
Verified
Journal Article
Closed access
TDTristana Y. Duvallet
Tristana Y. Duvallet
MMMajid Mahmoodabadi
Majid Mahmoodabadi
AOAnne E. Oberlink
Anne E. Oberlink
TRThomas L. Robl
Thomas L. Robl
RJRobert B. Jewell
Robert B. Jewell

22 September 2022 in Advances in Civil Engineering Materials
Verified
Journal Article
Closed access
TRThomas Robl
Thomas Robl
RJRobert Jewell
Robert Jewell
TDTristana Duvallet
Tristana Duvallet
EGErgin Gülcan
Ergin Gülcan
RRRobert Rathbone
Robert Rathbone
AOAnne Oberlink
Anne Oberlink
Class F fly ash from both fresh and stored sources, along with finely milled sand and limestone were tested by conventional strength index approaches based on ASTM C618-2019, Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete and EN 450-1:2012 - Fly ash for concrete. Definition, specifications and conformity criteria for pozzolan activity. Mortars were made with both European and U.S. standard sands. Pozzolanic activity was also measured directly by Ca(OH)2 uptake via thermogravimetric analysis and electrical resistivity. The EN 450 method proved a more reliable measure of pozzolanic activity than the ASTM equivalent, which provided false positives, probably due to the narrow gradation of the U.S. standard sand and the rheologic benefit of the fly ash on the mortar. A four-point Wenner probe was used to measure the electrical resistivity on the 40 × 40 × 160 mm mortar prisms. The resistivity correlated with the measure of strength index and pozzolanic activity by other methods. The pozzolanic reaction of the Class F fly ash was found to be relativity slow, with a latency period of at least 21 days and only small indications of activity at 28 days. Unlike compressive strength, the resistivity of the control mortars did not change significantly after 28 days and remained essentially flat over one year. The resistivity of the fly ash test prisms showed continuous increase over the same period, achieving 150 % to >500 % of control at 90 days. This may be contrasted with the compressive strength data of 90 % to 110 % for the EN-450 data. The measurement of resistivity is rapid, simple, precise, and non-destructive and made with inexpensive equipment that is relatable to pozzolanic activity. It is found to be more sensitive and selective than that provided by conventional strength index methods.

1 January 2017
Verified
Book Chapter
Closed access
Thomas AdamsThomas Adams
Thomas Adams
TRT. Robl
T. Robl

18 July 2008
Verified
Report
Open access
PDF file
TRT. L. Robl
T. L. Robl
Jack GroppoJack Groppo
Jack Groppo
RRR. Rathbone
R. Rathbone
BMB. Marrs
B. Marrs
RJR. Jewell
R. Jewell
The U.S. Department of Energy's Office of Scientific and Technical Information

11 April 2002
Verified
Report
Open access
PDF file
RRRobert F. Rathbone
Robert F. Rathbone
TRThomas L. Robl
Thomas L. Robl
Work completed in this reporting period focused primarily on continuing measurements of the rate of ammonia loss from concrete, and the measurement of ammonia gas in the air above concrete and flowable fill immediately after placement. Concrete slabs were prepared to monitor the loss of ammonia during mixing, the concentration in the airspace above the slabs soon after placement, and the total quantity of ammonia evolved over a longer time period. Variables tested include temperature, ventilation rate, water:cementitious (W:C) ratio, and fly ash source. Short-term data indicate that for concrete placed in areas with poor air ventilation the fly ash NH{sub 3} concentration should not exceed about 90 to 145 mg/kg ash, depending on the water:cement ratio and the fly ash replacement rate, if a concentration of 10 ppm NH{sub 3} in the air is assumed to be the maximum acceptable level. Longer-term experiments showed that the ammonia loss rate is dependent on ammonia source (that is ammoniated ash vs. non-ammoniated ash with ammonia added to the water), and is also dependent on W:C ratio and temperature. Experiments were also conducted to study the loss of ammonia from fresh concrete during mixing. It was found that a high water:cementitious mixmore » lost a greater percentage of ammonia than a low W:C mix, with a medium W:C mix losing an amount intermediate between these two. However, a larger batch size resulted in a smaller percentage of ammonia lost. The data suggest that a significant quantity of ammonia could be lost from Ready Mix concrete during transit, depending on the transit time, batch size, and mix proportions. « less