Background: Previous studies with small sample sizes reported contradicting findings as to whether pulmonary function tests can predict exercise-induced oxygen desaturation (EID). Objective: To evaluate whether forced expiratory volume in one second (FEV1), resting oxygen saturation (Spo2) and diffusion capacity for carbon monoxide (Dl c o) are predictors of EID in chronic obstructive pulmonary disease (COPD). Methods: We measured FEV1, Dl c o, Spo2 at rest and during a 6-min walking test as well as physical activity by an accelerometer. A drop in Spo2 of >4 to <90% was defined as EID. To evaluate associations between measures of lung function and EID univariate and multivariate analyses were used and positive/negative predictive values were calculated. Receiver operating characteristic curve analysis was performed to determine the most useful threshold in order to predict/exclude EID. Results: We included 154 patients with COPD (87 females). The mean FEV1 was 43.0% (19.2) predicted and the prevalence of EID was 61.7%. The only independent predictor of EID was FEV1 and the optimal cutoff value of FEV1 was at 50% predicted (area under ROC curve, 0.85; p < 0.001). The positive predictive value of a threshold of FEV1 <50% was 0.83 with a likelihood ratio of 3.03 and the negative predicting value of a threshold of FEV1 ≥80% was 1.0. The severity of EID was correlated with daily physical activity (r = –0.31, p = 0.008). Conclusions: EID is highly prevalent among patients with COPD and can be predicted by FEV1. EID seems to be associated with impaired daily physical activity which supports its clinical importance.
Objectively measuring daily physical activity (PA) using an accelerometer is a relatively expensive and time-consuming undertaking. In routine clinical practice it would be useful to estimate PA in patients with chronic obstructive pulmonary disease (COPD) with more simple methods. To evaluate whether PA can be estimated by simple tests commonly used in clinical practice in patients with COPD. The average number of steps per day was measured for 7 days with a SenseWear Pro™ accelerometer and used as gold standard for PA. A physical activity level (PAL) of <1.4 was considered very inactive. Univariate and multivariate analyses were used to examine the relationship between the 6-minute walking distance (6MWD), the number of stands in the Sit-to-Stand Test (STST), hand-grip strength and the total energy expenditure as assessed by the Zutphen Physical Activity Questionnaire (TEEZPAQ). ROC curve analysis was used to identify patients with an extremely inactive lifestyle (PAL<1.4). In 70 patients with COPD (21 females) with a mean [SD] FEV1 of 43.0 [22.0] %predicted, PA was found to be significantly and independently associated with the 6MWD (r = 0.69, 95% CI 0.54 to 0.80, p<0.001), STST (r = 0.51, 95% CI 0.31 to 0.66, p = 0.001) and TEEZPAQ (r = 0.50, 95% CI 0.30 to 0.66, p<0.001) but not with hand-grip strength. However, ROC curve analysis demonstrated that these tests cannot be used to reliably identify patients with an extremely inactive lifestyle. In patients with COPD simple tests such as the 6-Minute Walk Test, the Sit-to-Stand Test and the Zutphen Physical Activity Questionnaire cannot be used to reliably predict physical inactivity.
3 July 2014 in Multidisciplinary Respiratory Medicine
Resistance training of peripheral muscles has been recommended in order to increase muscle strength in patients with Chronic Obstructive Pulmonary Disease (COPD). However, whether peripheral muscle strength is associated with exercise performance (EP) and physical activity in daily life (PADL) in these patients needs to be investigated.
Background: Altered cardiac repolarization and increased dispersion of repolarization have been identified as risk factors for sudden cardiac death (SCD). The prevalence of and the mechanisms contributing to altered cardiac repolarization are currently unknown in COPD. Methods: In 91 COPD patients, 32 controls matched for age, cardiovascular risk and medication, and 41 healthy subjects, measures of cardiac repolarization and dispersion of repolarization (QTc interval, QT dispersion) were derived from 12-lead electrocardiography (ECG). Prevalence rates of heart rate corrected QT (QTc) >450ms and QT dispersion >60ms were determined to assess the number of subjects at risk for SCD. Univariate and multivariate analyses were used to identify possible factors contributing to altered cardiac repolarization. Results: QTc was found to be prolonged in 31.9% and QT dispersion in 24.2% of the COPD patients compared to 12.5% in matched controls and 0% in healthy subjects. The QTc interval was longer in COPD patients compared to matched and healthy controls respectively (437.9 ± 29.5 vs. 420.1 ± 25.3 ms, p = 0.001 and vs. 413.4 ± 18.2 ms, p < 0.001). QT dispersion was significantly increased in COPD patients compared to healthy subjects (45.4 (34.8 , 59.5) vs. 39.7 (29.3 , 54.8) ms, p = 0.049). Only oxygen saturation was independently associated with QTc duration in multivariate analysis (β = -0.29, p = 0.015). Conclusion: One third of a typical COPD population has altered cardiac repolarization and increased dispersion of repolarization, which may be related to hypoxia. Altered cardiac repolarization may expose these patients to an increased risk for malignant ventricular arrhythmias and SCD.
Background: Chronic obstructive pulmonary disease (COPD) is associated with impaired exercise tolerance, but it has not been established to what extent cardiac autonomic function impacts on exercise capacity. Objective: To evaluate whether there is an association between airflow limitation and cardiac autonomic function and whether cardiac autonomic function plays a role in exercise intolerance and daily physical activity (PA) in patients with COPD. Methods: Univariate and multivariate analyses were performed to evaluate the association between both 6-minute walking test (6MWT) and PA (steps per day) and pulmonary function, cardiac autonomic function (HR at rest, HRR and heart rate variability, HRV) in patients with COPD. Results: In 154 COPD patients (87 females, mean [SD]: age 62.5 [10.7] years, FEV1%predicted (43.0 [19.2]%), mean HR at rest was elevated (86.4 [16.4] beats/min) and HRV was reduced (33.69 [28.96] ms) compared to published control data. There was a significant correlation between FEV1 and HR at rest (r = -0.32, p < 0.001), between HR at rest and 6MWD (r = -0.26, p = 0.001) and between HR at rest and PA (r = -0.29, p = 0.010). No correlation was found between HRV and 6MWD (r = 0.089, p = 0.262) and PA (r = 0.075, p = 0.322). In multivariate analysis both HR and FEV1 were independent predictors of exercise capacity in patients with COPD. Conclusions: In patients with COPD the degree of airflow limitation is associated with HR at rest. The degree of airflow limitation and cardiac autonomic function, as quantified by HR at rest, are independently associated with exercise capacity in patients with COPD.