Michael Chang

Michael Chang

Auto-generated profile, based on publicly available information

Michael Chang

EE HTC, Taoyuan County, Taiwan (R.O.C)

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Neurobiology of Disease
Verified
Journal Article
Closed access
MCMichael Chang
Michael Chang
JDJoshua A. Dian
Joshua A. Dian
SDSuzie Dufour
Suzie Dufour
LWLihua Wang
Lihua Wang
HCHomeira Moradi Chameh
Homeira Moradi Chameh
TVTaufik A. Valiante
Taufik A. Valiante

12 May 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
MPM. Reza Pazhouhandeh
M. Reza Pazhouhandeh
MCMichael Chang
Michael Chang
TVTaufik A. Valiante
Taufik A. Valiante
RGRoman Genov
Roman Genov

1 February 2018
Verified
Conference Paper
Closed access
GOGerard O'Leary
Gerard O'Leary
MPM. Reza Pazhouhandeh
M. Reza Pazhouhandeh
MCMichael Chang
Michael Chang
DGDavid Groppe
David Groppe
TVTaufik A. Valiante
Taufik A. Valiante
RGRoman Genov
Roman Genov
The advancement of closed-loop neuromodulation for treating neurological disorders demands: (1) analog circuits monitoring the brain activity uninterruptedly even during neurostimulation, (2) energy-efficient high-efficacy processors for responsive, adaptive, personalized neurostimulation, and (3) safe neurostimulation paradigms with rich spatio-temporal stimuli for controlling the brain's complex dynamics. This paper presents an implantable neural interface processor (NURIP) that addresses these requirements — it performs brain state classification for reliable seizure prediction and contingent seizure abortion.

1 April 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
HKHossein Kassiri
Hossein Kassiri
FCFu Der Chen
Fu Der Chen
MSM. Tariqus Salam
M. Tariqus Salam
MCMichael Chang
Michael Chang
BVBehraz Vatankhahghadim
Behraz Vatankhahghadim
RGRoman Genov
Roman Genov
A hybrid 16-channel current-mode and the 8-channel optical implantable neurostimulating system is presented. The system generates arbitrary-waveform charge-balanced current-mode electrical pulses with an amplitude ranging from 50 mu A to 10 mA. An impedance monitoring feedback loop is employed to automatically adjust the supply voltage, yielding a load-optimized power dissipation. The 8-channel optical stimulator drives an array of LEDs, each with a maximum of 25 mA current amplitude, and reuses the arbitrary-waveform generation function of the electrical stimulator. The LEDs are assembled within a custom-made 4 x 4 ECoG grid electrode array, enabling precise optical stimulation of neurons with a 300 mu m pitch between the LEDs and simultaneous monitoring of the neural response by the ECoG electrode, at different distances of the stimulation site. The hybrid stimulation system is implemented on a mini-PCB, and receives power and stimulation commands inductively through a second board and a coil stacked on top of it. The entire system is sized at 3x2.5x1 cm(3) and weighs 7 grams. The system efficacy for electrical and optical stimulation is validated in-vivo using separate chronic and acute experiments.

19 January 2019 in Journal of Visualized Experiments
Verified
Journal Article
Closed access
PDF file
MCMichael Chang
Michael Chang
SDSuzie Dufour
Suzie Dufour
PCPeter L. Carlen
Peter L. Carlen
TVTaufik A. Valiante
Taufik A. Valiante
Controlling seizures remains a challenging issue for the medical community. To make progress, researchers need a way to extensively study seizure dynamics and investigate its underlying mechanisms. Acute seizure models are convenient, offer the ability to perform electrophysiological recordings, and can generate a large volume of electrographic seizure-like (ictal) events. The promising findings from acute seizure models can then be advanced to chronic epilepsy models and clinical trials. Thus, studying seizures in acute models that faithfully replicate the electrographic and dynamical signatures of a clinical seizure will be essential for making clinically relevant findings. Studying ictal events in acute seizure models prepared from human tissue is also important for making findings that are clinically relevant. The key focus in this paper is on the cortical 4-AP model due to its versatility in generating ictal events in both in vivo and in vitro studies, as well as in both mouse and human tissue. The methods in this paper will also describe an alternative method of seizure induction using the Zero-Mg2+ model and provide a detailed overview of the advantages and limitations of the epileptiform-like activity generated in the different acute seizure models. Moreover, by taking advantage of commercially available optogenetic mouse strains, a brief (30 ms) light pulse can be used to trigger an ictal event identical to those occurring spontaneously. Similarly, 30 - 100 ms puffs of neurotransmitters (Gamma-Amino Butyric Acid or glutamate) can be applied to the human tissue to trigger ictal events that are identical to those occurring spontaneously. The ability to trigger ictal events on-demand in acute seizure models offers the newfound ability to observe the exact sequence of events that underlie seizure initiation dynamics and efficiently evaluate potential anti-seizure therapies.

1 October 2015
Verified
Conference Paper
Closed access
HKHossein Kassiri
Hossein Kassiri
MSM. Tariqus Salam
M. Tariqus Salam
FCFu Der Chen
Fu Der Chen
BVBehraz Vatankhahghadim
Behraz Vatankhahghadim
NSNima Soltani
Nima Soltani
RGRoman Genov
Roman Genov
A hybrid current-mode and optogenetic miniature neurostimulating system is presented. The 16-channel electrical stimulator outputs arbitrary-waveform charge-balanced current-mode stimulation pulses with the amplitude ranging from 0.05mA to 10mA. To optimize power consumption, the supply voltage is automatically adjusted through an impedance monitoring feedback loop that gauges the minimum required headroom voltage. The 8-channel optogenetic stimulator reuses the arbitrary-waveform generation functions of the electrical stimulator. Each pulse-generator drives one LED with a maximum of 25mA. The LEDs are assembled within a custom-made 4×4 ECoG grid electrode array, which enables precise optical stimulation of neurons with a 300μm spatial resolution and simultaneous monitoring of the neural response by the ECoG electrode, at different distances of the stimulation site. The implantable system is a 3×2.5×1 cm 3 stack of a receiver coil and two mini-boards. The power is received by a 32-layer flexible inductive coil and is regulated by the wireless communication board. The adaptive neurostimulator board boosts the regulated voltage up to the level set by the feedback loop with a maximum of 24V. The system also receives stimulation parameters wirelessly from the amplitude-shift-keyed power carrier. Both electrical and optogenetic stimulation results from chronic and acute in vivo rodent experiments are presented.