Taylan Akgün

Taylan Akgün

Auto-generated profile, based on publicly available information

Taylan Akgün

Department of Cardiology, Başakşehir Çam and Sakura City Hospital, Basaksehir/İstanbul, Turkey

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2006 in American Journal of Hypertension
Verified
Journal Article
Open access
PDF file
OKOmer Faruk Karakaya
Omer Faruk Karakaya
IBIrfan Barutcu
Irfan Barutcu
AEAli Metin Esen
Ali Metin Esen
SDSerkan Dogan
Serkan Dogan
MSMustafa Saglam
Mustafa Saglam
CKCihangir Kaymaz
Cihangir Kaymaz
Background:. Expression of matrix metalloproteinase (MMP) has been shown in aortic dissection and aneurysms indicating increased proteolysis compared w

20 September 2022 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
TGTeyyar Gökdeniz
Teyyar Gökdeniz
YKYusuf Karavelioglu
Yusuf Karavelioglu
TATaylan Akgün
Taylan Akgün
MÇMuhammet Cihat Çelik
Muhammet Cihat Çelik

5 July 2021 in The Anatolian Journal of Cardiology
Verified
Journal Article
Open access
AUAbdulkadir Uslu
Abdulkadir Uslu
AKAyhan Kup
Ayhan Kup
SDSerdar Demir
Serdar Demir
KGKamil Gulsen
Kamil Gulsen
Batur Gonenc KanarBatur Gonenc Kanar
Batur Gonenc Kanar
ITIstanbul- Turkey
Istanbul- Turkey
Objective: This study aimed to evaluate the acute effect of cryoballoon ablation (CB-A) on electrocardiographic parameters that have been suggested to reflect heterogeneity in atrial conduction and ventricular repolarization. Methods: A total of 67 patients (52.6 +/- 13.2 years, 43 men) without any exclusion criteria who had undergone CB-A for atrial fibrillation (AF) between January 01, 2015, and December 31, 2018, constituted our study population. Electrographic recordings obtained before and after the ablation procedure on the same day were retrospectively evaluated for the P-wave dispersion, QTc dispersion, Tp-Te interval, and Tp-Te/QT ratio. The pre- and post-ablation values were tested for significant differences. The association of the possible CB-A-related changes in these parameters with AF recurrence during follow-up was evaluated. Results: P dispersion (30.1 +/- 6.8 vs. 35.9 +/- 9.4 ms, p<0.001), QT dispersion (20.7 +/- 7.5 vs. 24.0 +/- 8.8 ms, p<0.001), Tp-Te duration (on V5 83.6 +/- 8.1 vs. 110.2 +/- 9.5 ms, p<0.001), and Tp-Te/QT ratio (on V5 0.22 +/- 0.03 vs. 0.28 +/- 0.02, p<0.001) were observed to increase significantly after CB-A. There was no association between the magnitudes of change in any parameter and AF recurrence. Conclusion: CB-A had significant effects on electrocardiographic parameters related to atrial conduction and ventricular repolarization in the acute phase after CB-A. Further prospective studies are required to examine the time-related course of these alterations and their impact on clinical outcomes.

28 January 2024 in Marmara Medical Journal
Verified
Journal Article
Closed access
PDF file
SDSerdar Demır
Serdar Demır
AKAyhan Kup
Ayhan Kup
KGKamil Gulsen
Kamil Gulsen
AUAbdulkadir Uslu
Abdulkadir Uslu
ATAyhan Tosun
Ayhan Tosun
AKAlper Kepez
Alper Kepez
Objective: Premature ventricular complexes (PVCs) are common arrhythmias and catheter ablation (CA) is the major treatment in patients with PVCs. In this study, we aimed to share our experience on PVCs patients who had undergone CA. Patients and Methods: We investigated consecutive patients who had undergone CA because of PVCs between January 2015 and March 2021 in a single centre arrhythmia unit. Patients’ characteristics, rhythm Holter recordings, echocardiography results and CA outcomes were noted. Patients were followed up for 22.3±3.7 months. Descriptive statistics were used to demonstrate features of study patients. Results: Study population consisted of 645 patients; mean age was 51 ± 4.14 and 372 (57.7%) were male. Arrhythmia originated from the right ventricular outflow tract in 279 (46.6 %) patients, coronary cusps in 161 (26.9 %) patients, left ventricle summit in 50 (8.3%) patients and inside of the right or left ventricle in remaining patients. Sustained procedural success was achieved in 526 (88.1 %) patients. Recurrence was observed in 46 (6.7%) patients during follow-up. Major complication occurred in two patients (one procedural mortality due to coronary artery injury and one tamponade). Conclusion: Premature ventricular contraction ablation can be utilized safely with high success rate. Most PVCs originate from the right or left ventricular outflow tract.

25 September 2022 in Journal of Health Sciences and Medicine
Verified
Journal Article
Open access
PDF file
FAFüsun Afşar
Füsun Afşar
SKSerpil Kayali
Serpil Kayali
VKVildan Kesgi̇n
Vildan Kesgi̇n
TATaylan Akgün
Taylan Akgün
Objective: Although heart failure is a chronic and progressive disease, it is also a disease that requires the patient and caregivers who are not healthcare professionals to spend many years together in the process of follow-up, treatment, and care. Correct evaluation of the patient and caregiver in this process is one of the most important points that will guide the process. The aim of this study was to conduct a validity and reliability study of the Turkish version of the Caregiver Contributions to Self-Care of Heart Failure Index v.2- (CC-SCHFI) and to determine the contributions of caregivers of patients with heart failure. Material and Method: The study sample was formed of the caregivers of patients who presented at a training and research hospital with a diagnosis of heart failure, who voluntarily agreed to participate in the research. Data were collected using a Personal Information Form and the CC-SCHFI. For the reliability study of the language adaptation of the CC-SCHFI, the internal consistency coefficient and the item-total points reliability coefficient were used, and to determine structure validity, Explanatory Factor Analysis (EFA) and Confirmatory Factor Analysis (CFA) were applied. Results: The cultural adaptation to Turkish of the CC-SCHFI was found to be high. In the validity and reliability study, the structure validity and internal consistency were high and it was concluded that the scale could be used under the sub-dimension headings of “Recommendations for Protection”, “The Role of the Caregiver in Treatment Compliance”, and “Caregiver Practices”.

1 December 2022 in Kosuyolu Heart Journal
Verified
Journal Article
Open access
PDF file
FAFüsun Afşar
Füsun Afşar
SKSerpil Kayalı
Serpil Kayalı
VKVildan Kesgin
Vildan Kesgin
TATaylan Akgün
Taylan Akgün
HYHabip Yılmaz
Habip Yılmaz
Introduction: Heart failure is a chronic and progressive disease with increasing prevalence and incidence worldwide, despite advances in science and technology, and it necessitates long-term follow-up, treatment, and care. Self-care in heart failure is one of the fundamental elements of quality of life and disability-free living. The aim of this study was to assess the validity and reliability of the Turkish version of the Self-Care of Heart Failure Index v.2 (SCHFI). Patients and Methods: The study sample included 233 patients who presented with a diagnosis of heart failure and volunteered to participate in the research at a training and research hospital. The data were collected using a personal information form and the SCHFI. The SCHFI was translated into Turkish, and the internal consistency coefficient and the item-total points reliability coefficient were analyzed for the reliability study. To determine structure validity, Explanatory Factor Analysis and Confirmatory Factor Analysis were performed. Results: The adaptation of the SCHFI to Turkish culture was found to have high structure validity and internal consistency in the reliability and validity studies. Conclusion: We concluded that the Self-Care of Heart Failure Index can be used as a unidimensional scale.