1 July 2003 in Applied Optics
We present measurements of the local diattenuation and retardance of thin-film specimens by using techniques that combine near-field scanning optical microscopy (NSOM) and a novel polarization-modulation (PM) polarimetry utilizing Fourier analysis of the detected intensity signal. Generally, quantitative near-field polarimetry is hampered by the optical anisotropy of NSOM probes. For example, widely used aluminum-coated pulled-fiber aperture probes typically exhibit a diattenuation near 10%. Our analysis of aperture diattenuation demonstrates that the usual techniques for nulling a PM polarimeter result in a nonzero residual probe retardance in the presence of a diattenuating tip. However, we show that both diattenuation and retardance of the sample can be determined if the corresponding tip properties are explicitly measured and accounted for in the data. In addition, in thin films (<100 nm thick), where the sample retardance and diattenuation are often small, we show how to determine these polarimetric quantities without requiring alignment of the fast and diattenuating axes, which is a more general case than has been previously discussed. We demonstrate our techniques by using two types of polymer-film specimens: ultrahigh molecular weight block copolymers (recently noted for their photonic activity) and isotactic polystyrene spherulites. Finally, we discuss how changes in the tip diattenuation during data collection can limit the accuracy of near-field polarimetry and what steps can be taken to improve these techniques.
11 May 2015 in Applied Physics Letters
Fluorescence resonance energy transfer (FRET) from individual, dye-labeled RNA molecules confined in freely-diffusing attoliter-volume aqueous droplets is carefully compared to FRET from unconfined RNA in solution. The use of freely-diffusing droplets is a remarkably simple and high-throughput technique that facilitates a substantial increase in signal-to-noise for single-molecular-pair FRET measurements. We show that there can be dramatic differences between FRET in solution and in droplets, which we attribute primarily to an altered pH in the confining environment. We also demonstrate that a sufficient concentration of a non-ionic surfactant mitigates this effect and restores FRET to its neutral-pH solution value. At low surfactant levels, even accounting for pH, we observe differences between the distribution of FRET values in solution and in droplets which remain unexplained. Our results will facilitate the use of nanoemulsion droplets as attoliter volume reactors for use in biophysical and biochemical assays, and also in applications such as protein crystallization or nanoparticle synthesis, where careful attention to the pH of the confined phase is required.