BACKGROUND AND PURPOSE: Tumefactive demyelinating lesions with atypical features can mimic high-grade gliomas on conventional imaging sequences. The aim of this study was to assess the role of conventional imaging, DTI metrics (p:q tensor decomposition), and DSC perfusion in differentiating tumefactive demyelinating lesions and high-grade gliomas. MATERIALS AND METHODS: Fourteen patients with tumefactive demyelinating lesions and 21 patients with high-grade gliomas underwent brain MR imaging with conventional, DTI, and DSC perfusion imaging. Imaging sequences were assessed for differentiation of the lesions. DTI metrics in the enhancing areas and perilesional hyperintensity were obtained by ROI analysis, and the relative CBV values in enhancing areas were calculated on DSC perfusion imaging. RESULTS: Conventional imaging sequences had a sensitivity of 80.9% and specificity of 57.1% in differentiating high-grade gliomas (P = .049) from tumefactive demyelinating lesions. DTI metrics (p:q tensor decomposition) and DSC perfusion demonstrated a statistically significant difference in the mean values of ADC, the isotropic component of the diffusion tensor, the anisotropic component of the diffusion tensor, the total magnitude of the diffusion tensor, and rCBV among enhancing portions in tumefactive demyelinating lesions and high-grade gliomas (P ≤ .02), with the highest specificity for ADC, the anisotropic component of the diffusion tensor, and relative CBV (92.9%). Mean fractional anisotropy values showed no significant statistical difference between tumefactive demyelinating lesions and high-grade gliomas. The combination of DTI and DSC parameters improved the diagnostic accuracy (area under the curve = 0.901). Addition of a heterogeneous enhancement pattern to DTI and DSC parameters improved it further (area under the curve = 0.966). The sensitivity increased from 71.4% to 85.7% after the addition of the enhancement pattern. CONCLUSIONS: DTI and DSC perfusion add profoundly to conventional imaging in differentiating tumefactive demyelinating lesions and high-grade gliomas. The combination of DTI metrics and DSC perfusion markedly improved diagnostic accuracy.
Asleep-awake-asleep technique of anesthesia is used during awake craniotomy with or without securing airway. We assessed this technique using laryngeal mask airway (LMA) in two patients. Patients underwent awake craniotomy for epilepsy surgery and the removal of a frontotemporal glioma. After anesthesia induction, airway was secured using LMA. Anesthesia was maintained using oxygen, nitrous oxide and sevoflurane, supplemented with an infusion of propofol and remifentanil. Twenty minutes before corticography, anesthesia was discontinued and LMA removed. Both patients were awake and cooperative during the neurological assessment and surgery on eloquent areas. The LMA was reinserted before the closure of the dura and remained in place until the end of surgery. Both patients had no recall of events under anesthesia, although experienced mild pain and discomfort during awake phase of surgery. Both expressed complete satisfaction over the anesthetic management. Asleep-awake-asleep technique using LMA offers airway protection. The painful aspect of surgery can be performed under anesthesia, hence minimizing the duration of stress and pain. Patients remained awake and cooperative throughout the time of neurological testing.