30 June 2025 in Russian Journal of Biomechanics
The article considers the control system of a biotechnical system on the example of a wrist joint. A mathematical model of the control system is given, including feedback loops and PI controllers of the errors in angles and angular velocities errors of the wrist joint in the adduction-abduction and flexion-extension planes. The proposed mathemat-ical model also includes muscle dynamics block and the cross-coupling connections due to the nonorthogonality of motion in the adduction-abduction and flexion-extension plane caused by the nonorthogonal localization of the force application in the wrist joint. The delays that might be caused by the neurological processing and signa transmission are also considered. The PI controllers are tuned using the optimization procedure via genetic algorithm. The minimization criterion is based on the desired transient response characteristics such as step response time, steady-state error and overshoot. The steady-state error minimization in a mandatory criterion but others are optional that may be related to different considered biotechnical system objectives. Computational experi-ments are performed in which the tuning of PI controllers for the proposed system is implemented for various configurations corresponding to various criteria in the optimiza-tion problem. The results of these experiments showed the applicability of the consid-ered approach to tuning of the control system of a biotechnical system using optimiza-tion procedures via a genetic algorithm as a numerical optimization method.
7 August 2026 in Proceedings of the Southwest State University. Series: IT Management, Computer Science, Computer Engineering. Medical Equipment Engineering
The purpose of the research
is to construct and research a biotechnical control system using the Hill model for describing muscle dynamics, using the wrist joint as an example. The model is based on a new mathematical model capable of adequately describing muscle and joint dynamics during motion in three planes, including the sequential achievement of several predetermined angular positions, cross-couplings, and the physiological limitations of the wrist joint.
Methods
. To study the considered biotechnical system, a mathematical model is proposed that includes the dynamics of the joint in the planes of flexion, extension, abduction, and supination, which consists of a block of joint dynamics, blocks of muscle dynamics, and a block of criss-cross connections that take into account the relationship of movements in different planes. The dynamics of muscles is represented by three pairs of "agonist antagonist" muscles implemented on the basis of the three-component Hill model. Control actions are formed using PI regulators for angles and angular velocities in each control channel (in each plane of motion).
Results
. Computational experiments were performed where the wrist joint was sequentially moved to three predetermined angular positions. The resulting transient responses for angles and angular velocities demonstrated the system’s stability and the precise achievement of all target positions. Analysis of muscle lengths and tendon tension forces revealed the coordinated action of muscle pairs: the control torque is generated by changing the ratio of agonist and antagonist muscle forces.
Conclusion
. The obtained results confirm the adequacy of the developed mathematical model for describing the dynamics of a biotechnical system using the wrist joint and muscle-tendon complex as an example and demonstrate the fundamental feasibility of using the proposed approach for modeling biotechnical systems.
1 January 2026 in Proceedings in Cybernetics
The work addresses the problem of simulating grasping an object of a specific shape by a robotic manipulator. The robot under consideration is similar to the human hand in terms of kinematic configuration. The modeling mechanism includes several stages: positioning the robotic hand over the object, placing the manipulator’s fingers relative to the shape of the object grasped, calculating the contact force required to grasp the object, and moving the hand holding the object. The first and last phases are conducted by changing the coordinates of the robotic manipulator’s kinematic center. The finger positioning stage is reduced to solving the inverse kinematics problem through an evolutionary optimization method, i.e. a genetic algorithm. The grasping phase defines the relevant contact force based on resolving the tracking issue for a set value, which is a predetermined touch force. The amount of the assigned touch force is reliant on the required friction force between fingers and the object that ensures a firm grasp. The authors approximate the finger dynamics to second-order dynamics. The simulation findings reveal the applicability of the proposed method to the problem of object grasping using a robotic manipulator.
30 June 2022 in Российский журнал биомеханики
МБМосковский Государственный Технический Университет Им. Н.э. Баумана
Московский Государственный Технический Университет Им. Н.э. Баумана
Рассматривается система регулирования биотехнической системы на примере лучезапястного сустава. Приводится математическая модель системы регулирования, включающая в себя обратные связи и ПИ-регуляторы по ошибкам углов и угловых скоростей движения лучезапястного сустава в плоскостях приведения – отведения и растяжения – сжатия. Предлагаемая математическая модель также включает блок динамики мышц, и блок перекрестных связей, обусловленных неортогональностью движения в плоскостях приведения – отведения и растяжения – сжатия, что связано с неортогональностью линий действия сил в лучезапястном суставе. Помимо этого, учитываются также возможные запаздывания, которые могут быть связаны с нейрофизиологической обработкой информации, принятия решений и проведения управляющих сигналов. Настройка ПИ-регуляторов осуществляется с использованием генетического алгоритма в рамках оптимизационной задачи. Критерий минимизации строится на основе желаемых показателей качества переходных процессов, таких как время переходного процесса, установившаяся ошибка и величина перерегулирования. Минимизация установившейся ошибки является обязательным критерием, а остальные – опциональные, что обусловлено возможными различными целевыми задачами управления. Проводятся вычислительные эксперименты, в которых настройка ПИ-регуляторов для рассматриваемой системы реализуется для различных конфигураций, соответствующих различным критериям оптимизационной задачи. Результаты проведенных вычислительных экспериментов показывают принципиальную применимость рассмотренного подхода по настройке системы регулирования биотехнической системы с применением оптимизационных процедур при использовании генетического алгоритма в качестве численной оптимизации.