25 October 2021 in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
The electrocardiogram (ECG) is a widespread diagnostic tool in healthcare and supports the diagnosis of cardiovascular disorders. Deep learning methods are a successful and popular technique to detect indications of disorders from an ECG signal. However, there are open questions around the robustness of these methods to various factors, including physiological ECG noise. In this study, we generate clean and noisy versions of an ECG dataset before applying symmetric projection attractor reconstruction (SPAR) and scalogram image transformations. A convolutional neural network is used to classify these image transforms. For the clean ECG dataset, F1 scores for SPAR attractor and scalogram transforms were 0.70 and 0.79, respectively. Scores decreased by less than 0.05 for the noisy ECG datasets. Notably, when the network trained on clean data was used to classify the noisy datasets, performance decreases of up to 0.18 in F1 scores were seen. However, when the network trained on the noisy data was used to classify the clean dataset, the decrease was less than 0.05. We conclude that physiological ECG noise impacts classification using deep learning methods and careful consideration should be given to the inclusion of noisy ECG signals in the training data when developing supervised networks for ECG classification. This article is part of the theme issue ‘Advanced computation in cardiovascular physiology: new challenges and opportunities’.
1 October 2018 in Physiological Measurement
Current arterial pulse monitoring systems capture data at high frequencies (100-1000 Hz). However, they typically report averaged or low frequency summary data such as heart rate and systolic, mean and diastolic blood pressure. In doing so, a potential wealth of information contained in the high-fidelity waveform data is discarded, data which has long been known to contain useful information on cardiovascular performance. Here we summarise a new mathematical method, attractor reconstruction, which enables the quantification of arterial waveform shape and variability in real-time. The method can handle long streams of non-stationary data and does not require preprocessing of the raw physiological data by the end user. Whilst the detailed mathematical proofs have been described elsewhere (Aston et al 2008 Physiol. Meas. 39), the authors were motivated to write a summary of the method and its potential utility for biomedical researchers, physiologists and clinician readers. Here we illustrate how this new method may supplement and potentially enhance the sensitivity of detecting cardiovascular disturbances, to aid with biomedical research and clinical decision making.
10 March 2026 in Nature Cancer
Artificial intelligence (AI) promises to enhance breast cancer screening. Here we evaluated Google’s mammography AI system (version 1.2) across two phases: a retrospective study using 115,973 mammograms from five National Health Service screening services with 39-month follow-up and prospective noninterventional feasibility deployment at 12 sites (9,266 cases). The primary endpoint was AI sensitivity and specificity versus first reader using a 5% noninferiority margin. The secondary endpoints were performance versus second or consensus readers and breast-level analyses. Retrospectively, AI achieved superior sensitivity (0.541 versus 0.437 for first reader, P < 0.001) and noninferior specificity (0.943 versus 0.952, P < 0.001). Cancer detection rate increased from 7.54 to 9.33 per 1,000 women, with AI detecting 25.0% of interval cancers. Performance was particularly strong for first screens (39.3% fewer recalls, 8.8% higher detection) and invasive cancers. No systematic demographic disparities were observed. Simulated second-reader replacement reduced reading time by 32% while increasing detection by 17.7%. Prospective deployment confirmed technical feasibility but revealed a distribution shift requiring threshold recalibration. Implementation requires adaptive calibration and continuous monitoring to ensure safety and equity.