Nicholas A. White

Nicholas A. White

Auto-generated profile, based on publicly available information

Nicholas A. White

Independent Consultant, San Francisco, CA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2006 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
KYKing H. Yang
King H. Yang
JHJingwen Hu
Jingwen Hu
NWNicholas A. White
Nicholas A. White
AKAlbert I. King
Albert I. King
CCClifford C. Chou
Clifford C. Chou
PPPriya Prasad
Priya Prasad
Numerical analyses frequently accompany experimental investigations that study injury biomechanics and improvements in automotive safety. Limited by computational speed, earlier mathematical models tended to simplify the system under study so that a set of differential equations could be written and solved. Advances in computing technology and analysis software have enabled the development of many sophisticated models that have the potential to provide a more comprehensive understanding of human impact response, injury mechanisms, and tolerance. In this article, 50 years of publications on numerical modeling published in the Stapp Car Crash Conference Proceedings and Journal were reviewed. These models were based on: (a) author-developed equations and software, (b) public and commercially available programs to solve rigid body dynamic models (such as MVMA2D, CAL3D or ATB, and MADYMO), and (c) finite element models. A clear trend that can be observed is the increasing use of the finite element method for model development. A review of these modeling papers clearly indicates the progression of the state-of-the-art in computational methods and technologies in injury biomechanics.

29 April 2013 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
NWNicholas A. White
Nicholas A. White
DMDaniel P. Moreno
Daniel P. Moreno
FGF. Scott Gayzik
F. Scott Gayzik
JSJoel D. Stitzel
Joel D. Stitzel
Human body finite element (FE) models are beginning to play a more prevalent role in the advancement of automotive safety. A methodology has been developed to evaluate neck response at multiple levels in a human body FE model during simulated automotive impacts. Three different impact scenarios were simulated: a frontal impact of a belted driver with airbag deployment, a frontal impact of a belted passenger without airbag deployment and an unbelted side impact sled test. Cross sections were created at each vertebral level of the cervical spine to calculate the force and moment contributions of different anatomical components of the neck. Adjacent level axial force ratios varied between 0.74 and 1.11 and adjacent level bending moment ratios between 0.55 and 1.15. The present technique is ideal for comparing neck forces and moments to existing injury threshold values, calculating injury criteria and for better understanding the biomechanical mechanisms of neck injury and load sharing during sub-injurious and injurious loading.

4 September 2014 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
NWNicholas A. White
Nicholas A. White
KDKerry A. Danelson
Kerry A. Danelson
FGF. Scott Gayzik
F. Scott Gayzik
JSJoel D. Stitzel
Joel D. Stitzel
A finite element (FE) simulation environment has been developed to investigate aviator head and neck response during a simulated rotary-wing aircraft impact using both an FE anthropomorphic test device (ATD) and an FE human body model. The head and neck response of the ATD simulation was successfully validated against an experimental sled test. The majority of the head and neck transducer time histories received a CORrelation and Analysis (CORA) rating of 0.7 or higher, indicating good overall correlation. The human body model simulation produced a more biofidelic head and neck response than the ATD experimental test and simulation, including change in neck curvature. While only the upper and lower neck loading can be measured in the ATD, the shear force, axial force, and bending moment were reported for each level of the cervical spine in the human body model using a novel technique involving cross sections. This loading distribution provides further insight into the biomechanical response of the neck during a rotary-wing aircraft impact.

1 September 2014 in The Spine Journal
Verified
Journal Article
Closed access
NWNicholas A. White
Nicholas A. White
DMDaniel P. Moreno
Daniel P. Moreno
PBPhilip J. Brown
Philip J. Brown
FGF. Scott Gayzik
F. Scott Gayzik
WHWesley Hsu
Wesley Hsu
JSJoel D Stitzel
Joel D Stitzel

20 April 2009 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
PDF file
NWNicholas A. White
Nicholas A. White
PBPaul C. Begeman
Paul C. Begeman
WHWarren N. Hardy
Warren N. Hardy
KYKing H. Yang
King H. Yang
KOKoshiro Ono
Koshiro Ono
MBMichael J. Bey
Michael J. Bey
A total of eight low-speed, rear-end impact tests using two Post Mortem Human Subjects (PMHS) in a seated posture are reported. These tests were conducted using a HYGE-style mini-sled. Two test conditions were employed: 8 kph without a headrestraint or 16 kph with a headrestraint. Upper-body kinematics were captured for each test using a combination of transducers and high-speed video. A 3-2-2-2-accelerometer package was used to measure the generalized 3D kinematics of both the head and pelvis. An angular rate sensor and two single-axis linear accelerometers were used to measure angular speed, angular acceleration, and linear acceleration of T1 in the sagittal plane. Two high-speed video cameras were used to track targets rigidly attached to the head, T1, and pelvis. The cervical spine kinematics were captured with a high-speed, biplane x-ray system by tracking radiopaque markers implanted into each cervical vertebra. Vertebral angle time histories are reported for each biplane x-ray test. This study simultaneously investigates both the upper-body and cervical-spine kinematics of PMHS during low-speed, rear-end impacts.

5 April 2016 in SAE International Journal of Advances and Current Practices in Mobility
Verified
Conference Paper
Closed access
PDF file
LMLogan Miller
Logan Miller
JGJames Gaewsky
James Gaewsky
AWAshley Weaver
Ashley Weaver
JSJoel Stitzel
Joel Stitzel
NWNicholas White
Nicholas White
Crash reconstructions using finite element (FE) vehicle and human body models (HBMs) allow researchers to investigate injury mechanisms, predict injury risk, and evaluate the effectiveness of injury mitigation systems, ultimately leading to a reduced risk of fatal and severe injury in motor vehicle crashes (MVCs). To predict injuries, regional-level injury metrics were implemented into the Total Human Model for Safety (THUMS) full body HBM. THUMS was virtually instrumented with cross-sectional planes to measure forces and moments in the femurs, upper and lower tibias, ankles, pelvis (pubic symphysis, ilium, ischium, sacrum, ischial tuberosity, and inferior and superior pubic ramus), and the cervical, thoracic, and lumbar vertebrae and intervertebral discs. To measure accelerations, virtual accelerometers were implemented in the head, thoracic vertebrae, sternum, ribs, and pelvis. Three chest bands and an abdominal band were implemented to measure chest and abdominal deflection. Organ injury is assessed with volumetric strain-based metrics in the lung, liver, and spleen. The kinematic and kinetic data described were batch-processed using a custom-built program known as the Injury Prediction Post-Processor (IPPP) to evaluate common injury metrics and risk probabilities from literature. A total of 30 injury metrics are currently implemented in the IPPP, including Head Injury Criterion (HIC), Combined Thoracic Index (CTI), and cross-sectional forces and moments. We have observed improved ability and accuracy in predicting real-world injury using stress and strain analysis compared to traditionally employed criteria for anthropomorphic test devices (ATDs).