M. R. Williams

M. R. Williams

Auto-generated profile, based on publicly available information

M. R. Williams

Lawrence Berkeley National Laboratory

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 October 2025 in Physical Review Letters
Verified
Journal Article
Open access
TBT. K. Bui
T. K. Bui
CCC. L. Chang
C. L. Chang
YCY.-Y. Chang
Y.-Y. Chang
LCL. Chaplinsky
L. Chaplinsky
CFC. W. Fink
C. W. Fink
TCTESSERACT Collaboration
TESSERACT Collaboration
We present results of a search for spin-independent dark matter-nucleus interactions in a 1 cm 2 by 1 mm thick (0.233 g) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves an rms baseline energy resolution of 361.5 ( 4 ) m eV (statistical error), the best for any athermal phonon detector to date. With an exposure of 0.233 g × 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 M eV / c 2 , with the lowest unexplored cross section of 4 × 10 − 32 c m 2 at 87 M eV / c 2 . We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low energy backgrounds that are coupled to individual sensors.

1 March 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
RAR. Anthony-Petersen
R. Anthony-Petersen
CCC. L. Chang
C. L. Chang
YCY.-Y. Chang
Y.-Y. Chang
LCL. Chaplinsky
L. Chaplinsky
CFC. W. Fink
C. W. Fink
MWM. R. Williams
M. R. Williams
We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

29 December 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
CCC. L. Chang
C. L. Chang
YCY.-Y. Chang
Y.-Y. Chang
MGMaurice Garcia-Sciveres
Maurice Garcia-Sciveres
WGW. Guo
W. Guo
SHS. A. Hertel
S. A. Hertel
VYV. G. Yefremenko
V. G. Yefremenko
Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE ν NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. In this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68±0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.

26 November 2024 in Physical Review Letters
Verified
Journal Article
Open access
JAJ Aalbers
J Aalbers
DAD S Akerib
D S Akerib
AMA K Al Musalhi
A K Al Musalhi
FAF Alder
F Alder
CAC S Amarasinghe
C S Amarasinghe
LCLZ Collaboration
LZ Collaboration
The LUX-ZEPLIN (LZ) experiment is a dual-phase xenon time project chamber operating in the Sanford Underground Research Facility in South Dakota, USA. We report on the results of a relativistic extension to the nonrelativistic effective field theory (NREFT) from a 5.5 t fiducial mass and 60 live days of exposure. We present constraints on couplings from covariant interactions arising from the coupling of vector, axial currents, and electric dipole moments of the nucleon to the magnetic and electric dipole moments of the weakly interacting massive particle which cannot be described by recasting previous results described by an NREFT. Using a profile-likelihood ratio analysis, in an energy region between 0 keV nr to 270 keV nr , we report 90% confidence level exclusion limits on the coupling strength of five interactions in both the isoscalar and isovector bases. Published by the American Physical Society 2024

23 June 2022 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ABA. Biekert
A. Biekert
LCL. Chaplinsky
L. Chaplinsky
CFC.W. Fink
C.W. Fink
MGM. Garcia-Sciveres
M. Garcia-Sciveres
WGW.C. Gillis
W.C. Gillis
MWM.R. Williams
M.R. Williams

19 November 2002
Verified
Conference Paper
Open access
Bruce CarlstenBruce Carlsten
Bruce Carlsten
MMM.L. Milder
M.L. Milder
JKJ.M. Kinross-Wright
J.M. Kinross-Wright
DFD.W. Feldman
D.W. Feldman
SRS. Russell
S. Russell
MWM. Williams
M. Williams