15 August 2015 in Journal of Clinical Sleep Medicine
Daylight saving time (DST) has been established with the intent to reduce energy expenditure, however unintentional effects on sleep and vigilance have not been consistently measured. The objective of this study was to test the hypothesis that DST adversely affects high school students' sleep and vigilance on the school days following its implementation. A natural experiment design was used to assess baseline and post-DST differences in objective and subjective measures of sleep and vigilance by actigraphy, sleep diary, sleepiness scale, and psychomotor vigilance testing (PVT). Students were tested during school days immediately preceding and following DST. A total of 40 high school students were enrolled in this study; 35 completed the protocol. Sleep duration declined by an average of 32 minutes on the weeknights post-DST, reflecting a cumulative sleep loss of 2 h 42 min as compared to the baseline week (p = 0.001). This finding was confirmed by sleep diary analyses, reflecting an average sleep loss of 27 min/night (p = 0.004) post-DST. Vigilance significantly deteriorated, with a decline in PVT performance post-DST, resulting in longer reaction times (p < 0.001) and increased lapses (p < 0.001). Increased daytime sleepiness was also demonstrated (p < 0.001). The early March DST onset adversely affected sleep and vigilance in high school students resulting in increased daytime sleepiness. Larger scale evaluations of sleep impairments related to DST are needed to further quantify this problem in the population. If confirmed, measures to attenuate sleep loss post-DST should be implemented.
1 June 2014 in Sleep Medicine
18 June 2018 in BMC Geriatrics
Disturbances in sleep and circadian rhythms are common among residents of long-term care facilities. In this systematic review, we aim to identify and evaluate the literature documenting the outcomes associated with non-pharmacological interventions to improve nighttime sleep among long-term care residents. The Preferred Reporting Items for Systematic Reviews guided searches of five databases (MEDLINE, Embase, CINAHL, Scopus, and Cochrane Library) for articles reporting results of experimental or quasi-experimental studies conducted in long-term care settings (nursing homes, assisted-living facilities, or group homes) in which nighttime sleep was subjectively or objectively measured as a primary outcome. We categorized each intervention by its intended use and how it was administered. Of the 54 included studies evaluating the effects of 25 different non-pharmacological interventions, more than half employed a randomized controlled trial design (n = 30); the others used a pre-post design with (n = 11) or without (n = 13) a comparison group. The majority of randomized controlled trials were at low risk for most types of bias, and most other studies met the standard quality criteria. The interventions were categorized as environmental interventions (n = 14), complementary health practices (n = 12), social/physical stimulation (n = 11), clinical care practices (n = 3), or mind-body practices (n = 3). Although there was no clear pattern of positive findings, three interventions had the most promising results: increased daytime light exposure, nighttime use of melatonin, and acupressure. Non-pharmacological interventions have the potential to improve sleep for residents of long-term care facilities. Further research is needed to better standardize such interventions and provide clear implementation guidelines using cost-effective practices.
11 May 2013 in Current Atherosclerosis Reports
1 August 2012 in Journal Of Clinical Neurophysiology
Purpose: Periodic limb movements (PLMs) and obstructive sleep apnea (OSA) may present as overlapping conditions. This study investigated the occurrence of PLM during continuous positive airway pressure (CPAP) titration, with the hypothesis that the presence of PLM during CPAP represented “unmasking” of a coexisting sleep disorder. Methods: A total of 78 polysomnographic recordings in 39 OSA subjects with an hourly PLM index ≥5 during CPAP application were evaluated. Results: Application of CPAP significantly improved sleep architecture without change in the PLM index when compared with baseline. The PLM indices and PLM arousal indices were linearly correlated during both nights (r = 0.553, P < 0.01; r = 0.548, P < 0.01, respectively). Eleven subjects with low PLM indices at baseline had greater changes in the PLM index as compared with the sample remainder (P = 0.004). Sixteen subjects with significantly lower PLM indices at baseline required optimal CPAP levels higher than the sample average of 8.2 cm H2O (P = 0.032). These subjects also showed significantly higher median apnea–hypopnea index (AHI) at baseline than the sample remainder (74.4 events per hour [range: 24.2–124.4 events per hour] vs. 22.7 events per hour [range: 8.6–77.4 events per hour], respectively, P < 0.001). Conclusions: These findings suggest that PLM seen during CPAP titration may be related to a concurrent sleep disorder because of “unmasking” in patients with treated OSA.
8 February 2020 in Sleep and Breathing