Valérie Dumaine

Valérie Dumaine

Auto-generated profile, based on publicly available information

Valérie Dumaine

Department of Plastic, Reconstructive, and Aesthetic Surgery, Hôpital Européen Georges Pompidou, Assistance Publique des Hôpitaux de Paris, Department of Anatomy, UFR Biomédicale des Saints-Pères, Université de Paris

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in The Bone & Joint Journal
Verified
Journal Article
Closed access
OLO. Lauthe
O. Lauthe
MSM. Soubeyrand
M. Soubeyrand
ABA. Babinet
A. Babinet
VDV. Dumaine
V. Dumaine
PAP. Anract
P. Anract
DBD. J. Biau
D. J. Biau
Aims: The primary aim of this study was to determine the morbidity of a tibial strut autograft and characterize the rate of bony union following its use. Patients and Methods: We retrospectively assessed a series of 104 patients from a single centre who were treated with a tibial strut autograft of > 5 cm in length. A total of 30 had a segmental reconstruction with continuity of bone, 27 had a segmental reconstruction without continuity of bone, 29 had an arthrodesis and 18 had a nonunion. Donor-site morbidity was defined as any event that required a modification of the postoperative management. Union was assessed clinically and radiologically at a median of 36 months (IQR, 14 to 74). Results: Donor-site morbidity occurred in four patients (4%; 95% confidence interval (CI) 1 to 10). One patient had a stress fracture of the tibia, which healed with a varus deformity, requiring an osteotomy. Two patients required evacuation of a haematoma and one developed anterior compartment syndrome which required fasciotomies. The cumulative probability of union was 90% (95% CI 80 to 96) at five years. The type of reconstruction (p = 0.018), continuity of bone (p = 0.006) and length of tibial graft (p = 0.037) were associated with the time to union. Conclusion: The tibial strut autograft has a low risk of morbidity and provides adequate bone stock for treating various defects of long bones. Cite this article: Bone Joint J 2018;100-B:667–74.

1 September 2011 in The Journal of Bone and Joint Surgery. British volume
Verified
Journal Article
Closed access
PDF file
DBD. J. Biau
D. J. Biau
MMM. Meziane
M. Meziane
RBR. S. Bhumbra
R. S. Bhumbra
VDV. Dumaine
V. Dumaine
ABA. Babinet
A. Babinet
PAP. Anract
P. Anract
The purpose of this study was to define immediate post-operative ‘quality’ in total hip replacements and to study prospectively the occurrence of failure based on these definitions of quality. The evaluation and assessment of failure were based on ten radiological and clinical criteria. The cumulative summation (CUSUM) test was used to study 200 procedures over a one-year period. Technical criteria defined failure in 17 cases (8.5%), those related to the femoral component in nine (4.5%), the acetabular component in 32 (16%) and those relating to discharge from hospital in five (2.5%). Overall, the procedure was considered to have failed in 57 of the 200 total hip replacements (28.5%). The use of a new design of acetabular component was associated with more failures. For the CUSUM test, the level of adequate performance was set at a rate of failure of 20% and the level of inadequate performance set at a failure rate of 40%; no alarm was raised by the test, indicating that there was no evidence of inadequate performance. The use of a continuous monitoring statistical method is useful to ensure that the quality of total hip replacement is maintained, especially as newer implants are introduced.

22 November 2019 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
NLNicolas de l’Escalopier
Nicolas de l’Escalopier
VDValérie Dumaine
Valérie Dumaine
GAGuillaume Auberger
Guillaume Auberger
ABAntoine Babinet
Antoine Babinet
JCJean-Pierre Courpied
Jean-Pierre Courpied
MHMoussa Hamadouche
Moussa Hamadouche

6 November 2010 in International Orthopaedics
Verified
Journal Article
Open access
PDF file
MHMoussa Hamadouche
Moussa Hamadouche
MKMathieu Karoubi
Mathieu Karoubi
VDValérie Dumaine
Valérie Dumaine
JCJean Pierre Courpied
Jean Pierre Courpied
Acetabular osteolysis associated with socket loosening is one of the main long-term complications of total hip arthroplasty. In case of major bone loss, where <50% host bone coverage can be obtained with a porous-coated cementless cup, it is generally agreed that a metal ring or cage in association with a cemented component and allograft bone should be used. In order to promote allograft bone consolidation and incorporation, we have associated demineralised bone matrix (DBM, Grafton® A Flex) to the construct ion. Here we describe the technical details of major acetabular reconstruction using the Kerboull acetabular reinforcement device with allograft bone and DBM. This device has a hook that must be placed under the teardrop of the acetabulum and a plate for iliac fixation. The main advantages of this device are help in restoring the normal centre of hip rotation, guiding the reconstruction and partially unloading the graft. The Kerboull acetabular reinforcement device has provided a 92% survival rate free of loosening at 13-year follow-up in a consecutive series of 60 type III and IV deficiencies. Our preliminary results using DBM indicate faster allograft consolidation and remodelling.

1 May 2009 in Journal de Radiologie
Verified
Journal Article
Closed access
FTF Thévenin
F Thévenin
VDV Dumaine
V Dumaine
AFA Feydy
A Feydy
RCR Campagna
R Campagna
HGH Guerini
H Guerini
ACA Chevrot
A Chevrot

7 February 2020 in Plastic and Reconstructive Surgery
Verified
Journal Article
Open access
MLMartin Md Lhuaire
Martin Md Lhuaire
ISIgnacio Garrido Sáenz
Ignacio Garrido Sáenz
VCVictoire Cladière-Nassif
Victoire Cladière-Nassif
VDValérie Dumaine
Valérie Dumaine
LLLaurent Lantieri
Laurent Lantieri
An abstract is unavailable. This article is available as a PDF only.