5 April 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Acoustical hologram generation can be achieved via controlled beam shaping by engineering the transmitted phases to create a desired pattern. Optically inspired phase retrieval algorithms and standard beam shaping methods assume continuous wave (CW) insonation, which successfully generate acoustic holograms for therapeutic applications that involve long burst transmissions. However, a phase engineering technique designed for single-cycle transmission and capable of achieving spatiotemporal interference of the transmitted pulses is needed for imaging applications. Toward this goal, we developed a multilevel residual deep convolutional network for calculating the inverse process that will yield the phase map for the creation of a multifoci pattern. The ultrasound deep learning (USDL) method was trained on simulated training pairs of multifoci patterns in the focal plane and their corresponding phase maps in the transducer plane, where propagation between the planes was performed via singe cycle transmission. The USDL method outperformed the standard Gerchberg–Saxton (GS) method, when transmitted with single cycle excitation, in parameters including the number of focal spots that were generated successfully and their pressure and uniformity. In addition, the USDL method was shown to be flexible in generating patterns with large focal spacing, uneven spacing, and nonuniform amplitudes. In simulations, the largest improvement was obtained for four foci patterns, where the GS method succeeded in creating 25% of the requested patterns, while the USDL method successfully created 60% of the patterns. These results were confirmed experimentally via hydrophone measurements. Our findings suggest that deep learning-based beam shaping can facilitate the next generation of acoustical holograms for ultrasound imaging applications.
19 October 2023 in Physics in Medicine & Biology
Objective . Develop a dense algorithm for calculating the speed-of-sound shift between consecutive acoustic acquisitions as a noninvasive means to evaluating temperature change during thermal ablation. Methods . An algorithm for dense speed-of-sound shift imaging (DSI) was developed to simultaneously incorporate information from the entire field of view using a combination of dense optical flow and inverse problem regularization, thus speeding up the calculation and introducing spatial agreement between pixels natively. Thermal ablation monitoring consisted of two main steps: pixel shift tracking using Farneback optical flow, and mathematical modeling of the relationship between the pixel displacement and temperature change as an inverse problem to find the speed-of-sound shift. A calibration constant translates from speed-of-sound shift to temperature change. The method performance was tested in ex vivo samples and compared to standard thermal strain imaging (TSI) methods. Main results . Thermal ablation at a frequency of 2 MHz was applied to an agarose phantom that created a speed-of-sound shift measured by an L12-5 imaging transducer. A focal spot was reconstructed by solving the inverse problem. Next, a thermocouple measured the temperature rise during thermal ablation of ex vivo chicken breast to calibrate the setup. Temperature changes between 3 °C and 15 °C was measured with high thermometry precision of less than 2 °C error for temperature changes as low as 8 °C. The DSI method outperformed standard TSI in both spatial coherence and runtime in high-intensity focused ultrasound-induced hyperthermia. Significance . Dense ultrasonic speed-of-sound shift imaging can successfully monitor the speed-of-sound shift introduced by thermal ablation. This technique is faster and more robust than current methods, and therefore can be used as a noninvasive, real time and cost-effective thermometry method, with high clinical applicability.
4 January 2026 in bioRxiv
Accurate temperature monitoring during cryoablation, a minimally invasive technique that destroys tissue locally by forming an ice ball around an inserted cryoprobe, is vital for achieving complete ablation while protecting surrounding tissue. We present a dense slowness-shift imaging method that estimates local speed-of-sound changes from ultrasound B-mode images using optical flow. This single-transducer, image-based approach enables mapping of spatial temperature change without requiring additional hardware. Cryoablation experiments in a tissue-mimicking phantom and ex vivo turkey breast demonstrated that slowness deviation increases with decreasing temperature. In the phantom, the dependence was linear (α a = -20.70 ηs·m −1 C° −1 ), while in turkey breast it presented an exponential relationship (α t = 34.04×exp(0.075(-ΔT)) ηs·m −1 C° −1 ). The algorithm detected sub-degree temperature variations and accurately tracked cooling down to -39.4 ± 5.6 °C. This work demonstrates the feasibility of ultrasound-based, noninvasive temperature monitoring during cryoablation, providing a scalable, real-time alternative to existing invasive or high-cost thermal assessment techniques.
20 May 2026 in Physics in Medicine & Biology
Objective. To accurately monitor temperature during cryoablation, a minimally invasive technique that destroys tissue locally by forming an ice ball around an inserted cryoprobe. Approach. We present a dense slowness-shift imaging method that estimates local speed-of-sound changes from ultrasound (US) B-mode images using optical flow. This single-transducer, image-based approach enables mapping of spatial temperature change without requiring additional hardware. Cryoablation experiments were conducted in a tissue-mimicking phantom and ex vivo turkey breast. Main results. Slowness deviation increased with decreasing temperature. In the phantom, the dependence was linear ( α a = − 20.70 η s·m −1 C° −1 ), while in turkey breast it followed an exponential relationship ( α t = 34.04 × exp (0.075(−ΔT)−1) η s·m −1 C° −1 ). The algorithm detected sub-degree temperature variations and accurately tracked cooling down to −39.4 ± 5.6 °C. Significance. Accurate temperature monitoring is essential for effective and safe cryoablation. This work demonstrates the feasibility of US-based, noninvasive temperature monitoring during cryoablation, providing a scalable, real-time alternative to existing invasive or high-cost thermal assessment techniques.