Arnaud Meylan

Arnaud Meylan

Auto-generated profile, based on publicly available information

Arnaud Meylan

Department of Orthopedics and Traumatology, University Hospital Centre and University of Lausanne (CHUV), Switzerland

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2024 in JSES International
Verified
Journal Article
Open access
SBStefan Bauer
Stefan Bauer
AMArnaud Meylan
Arnaud Meylan
JMJaad Mahlouly
Jaad Mahlouly
WSWei Shao
Wei Shao
William G BlakeneyWilliam G Blakeney
William G Blakeney
Friction is the primary cause of notching in reverse shoulder arthroplasty during internal, external rotation (IR/ER), and extension (EXT). To address notching, glenosphere eccentricity (ECC) was introduced. The primary objective of this study was to investigate different positions of glenosphere ECC to determine whether there is an optimal position for impingement-free range of motion. In this computer model study, 10 female CTs were analyzed and EXT, ER, IR, and adduction simulated (18 models.) A 135° stem with a +10° liner (145°) was combined with a 25-mm standard/or +3-mm lateralized baseplate (BP) and a 36-mm +2-mm eccentric glenosphere in 4 ECC positions (50° posterior; 30° posterior; 30° anterior; 50° anterior) from the reference position 0° neutral (10 models). Additionally, a concentric 39-mm glenosphere was tested (+2 models). A 0° insert, 135° neck shaft angle (NSA), was tested with a 25-mm standard/or +3-mm BP for 3 configurations (30° posterior; neutral; 39 mm; +6 models). Compared to the 0° neutral reference position, 30° posterior dialing improved the mean ER (group 145°: 40° vs. 38°, group 145° + 3: 51° vs. 49°, both P < .0001), and EXT (group 145°: 35° vs. 34°, P = .029, group 145° + 3: 57° vs. 47°, P = .046, but at the expense of IR (group 145°: 83° vs. 87°, group 145° + 3: 87° vs. 91°, both P < .0001). The position 30° anterior increased IR (group 145°: 90° vs. 87°, group 145° + 3: 94° vs. 91°, both P < .0001) at the expense of ER (group 145°: 33° vs. 38°, group 145° + 3: 44° vs. 49°, both P < .0001) and EXT (group 145°: 24° vs. 34°, P = .055, group 145° +3 mm: 39° vs. 47°, P = .0042). For group 145°, 0° neutral was the best position for combined EXT + IR (121°) compared to 30° posterior/30° anterior/39 mm/50° posterior/50° anterior (118°/113°/118°/113°/110°, P < .0001/P = .15/P = .076/P < .0001/P = .074, respectively) and IR + ER (125° vs. 122°/123°/123°/118°/119°/, P < .001/P = .0028/P = .7/P < .0001/P = .0001, respectively). Lateralization, but most effectively a 135° NSA improved combined EXT + IR + ER + adduction (group 145°: 179° vs. group 135°: 243°, group 145° + 3: 215° vs. group 135° + 3: 276°, P = .0019/P = .00019, respectively). The influence of position 0°neutral or 30°posterior became marginal with a 135°NSA. Posterior dialing of the ECC increases EXT and ER but at the expense of IR. Lateralization, but most effectively a 135° NSA, increase impingement-free motion. A larger noneccentric glenosphere on the same BP is a safe all-round solution to prevent ECC positioning outliers.

25 November 2025
Verified
Journal Article
Open access
AMArnaud Meylan
Arnaud Meylan
ATAlexandre Terrier
Alexandre Terrier
SMSophie Rosa Merckaert
Sophie Rosa Merckaert
JWJulien Wegrzyn
Julien Wegrzyn
SSSylvain Steinmetz
Sylvain Steinmetz
Tibial tubercle osteotomy (TTO) is rarely required to achieve adequate exposure during complex revision total knee arthroplasty (TKA). Although generally considered a salvage option, concerns persist regarding its potential complications and impact on postoperative function, and clinical data remain limited. This study aimed to describe the clinical and radiographic outcomes of aseptic revision TKA requiring TTO; outcomes from cases revised without TTO are reported as contextual, exploratory data. A retrospective review was conducted on 128 patients who underwent aseptic revision TKA between May 2009 and December 2020. The cohort included 50 TTO and 78 standard parapatellar arthrotomy without TTO (non-TTO). The decision to perform a TTO was made intraoperatively when standard exposure techniques did not permit adequate patellar mobilization without excessive tension on the extensor mechanism. Clinical and radiographic outcomes were assessed within each group and, on an exploratory basis, between groups including revision and complication rates, postoperative range of motion, patellar height ratios, and osteotomy union. The TTO group achieved a union rate of 98%, with 14% of patients experiencing TTO-related complications (mainly hardware irritation). Revision was required in 18% of TTO and 15% of non-TTO cases. Flexion significantly improved in both groups; exploratory analysis suggested no significant differences between groups (p = 0.97). Patellar height remained stable. TTO is an uncommon but reliable salvage exposure in aseptic revision TKA, with high union and low reoperation risk. It did not compromise knee flexion or patellar height at mid-term follow-up. Prospective studies with patient-reported outcomes and higher-complexity cases are needed. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

1 October 2025 in JBJS Open Access
Verified
Journal Article
Open access
AMArnaud Meylan
Arnaud Meylan
ATAlexandre Terrier
Alexandre Terrier
SMSophie Rosa Merckaert
Sophie Rosa Merckaert
JWJulien Wegrzyn
Julien Wegrzyn
SSSylvain Steinmetz
Sylvain Steinmetz
Background: Tibial tubercle osteotomy (TTO) is rarely required to achieve adequate exposure during complex revision total knee arthroplasty (TKA). Although generally considered a salvage option, concerns persist regarding its potential complications and impact on postoperative function, and clinical data remain limited. This study aimed to describe the clinical and radiographic outcomes of aseptic revision TKA requiring TTO; outcomes from cases revised without TTO are reported as contextual, exploratory data. Methods: A retrospective review was conducted on 128 patients who underwent aseptic revision TKA between May 2009 and December 2020. The cohort included 50 TTO and 78 standard parapatellar arthrotomy without TTO (non-TTO). The decision to perform a TTO was made intraoperatively when standard exposure techniques did not permit adequate patellar mobilization without excessive tension on the extensor mechanism. Clinical and radiographic outcomes were assessed within each group and, on an exploratory basis, between groups including revision and complication rates, postoperative range of motion, patellar height ratios, and osteotomy union. Results: The TTO group achieved a union rate of 98%, with 14% of patients experiencing TTO-related complications (mainly hardware irritation). Revision was required in 18% of TTO and 15% of non-TTO cases. Flexion significantly improved in both groups; exploratory analysis suggested no significant differences between groups (p = 0.97). Patellar height remained stable. Conclusions: TTO is an uncommon but reliable salvage exposure in aseptic revision TKA, with high union and low reoperation risk. It did not compromise knee flexion or patellar height at mid-term follow-up. Prospective studies with patient-reported outcomes and higher-complexity cases are needed. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.