Brwa Hama Saeed Hamah Ali

Brwa Hama Saeed Hamah Ali

Auto-generated profile, based on publicly available information

Brwa Hama Saeed Hamah Ali

Affiliation Ph.D. Student at Civil Engineering Department, College of Engineering, University of Sulaimani, Sulaymaniyah, Iraq

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2024 in Emerging Technologies and Engineering Journal
Verified
Journal Article
Open access
PDF file
SAsoran Abdrahman Ahmad
soran Abdrahman Ahmad
Bilal Kamal MohammedBilal Kamal Mohammed
Bilal Kamal Mohammed
SRSerwan Khwrshid Rafiq
Serwan Khwrshid Rafiq
BABrwa Hama Saeed Hamah Ali
Brwa Hama Saeed Hamah Ali
KFKawa Omer Fqi
Kawa Omer Fqi
The present study focuses on proposing various statistical models, such as linear regression (LR), nonlinear regression (NLR), and artificial neural network (ANN), to forecast the compressive strength of environmentally friendly high-strength concrete, incorporating waste agricultural material like palm oil fuel ash (POFA). A dataset of 105 experimental observations was compiled from existing literature to achieve this goal, which was subsequently partitioned into training and testing subsets. Each model was developed based on the training data and evaluated using the testing data. The performance of each proposed model was gauged using diverse statistical metrics like the coefficient of determination, mean absolute error, root mean square error, and scatter index to identify the most effective model. The findings indicate that using POFA with a finer particle size exerts a greater influence on the concrete's properties. The replacement was done using the weight method, and the predicted equation worked with the variation of the used rate of POFA from 0 to 60% of total binder weight. Substituting a portion of cement with POFA leads to a reduction in the heat of hydration and an extension of the setting time. The optimal percentage of POFA is 30%, yielding mechanical properties superior to those of the control mixture, particularly in the later stages of development. Among the models considered, the ANN demonstrates superior efficiency and accuracy in predicting the compressive strength of conventional concrete modified with POFA compared to LR and NLR models. This is evident in the ANN's higher R2 values of 52% and 16%, respectively, and a lower scatter index below 0.1%.

30 December 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
BHBrwa Hamah Saeed Hamah-Ali
Brwa Hamah Saeed Hamah-Ali
MQMohamed Raouf Abdul Qadir
Mohamed Raouf Abdul Qadir
In order to investigate the effect of pre-loading damage on the structural performance of Carbon Fiber Reinforced Polymer (CFRP) strengthened Reinforced Concrete (R.C.) beams, experimental and Finite Element Modelling (FEM) investigation was carried out on six R.C. beams. Five of the R.C. beams were damaged up to different levels of strain in the main steel bars before Flexure CFRP strengthening. One of the R.C. beams loaded up to failure and was kept as a control beam for comparison. The experimental results showed that the failure mode of the CFRP strengthened specimen was controlled by CFRP debonding followed by concrete crushing; however, the control beam failed in concrete crushing after yielding the steel bars, which is a ductile failure. The CFRP sheet increases the strength and initial stiffness of the R.C. beams and reduces ductility and toughness. Also, CFRP application increases the first crack and yielding steel bars load by 87.4% and 34.4%, respectively. Furthermore, the pre-damage level does not influence the strength and ductility of the strengthened R.C. beams except for the highest damage levels, which experienced a slight decrease in load capacity and ductility. However, the initial stiffness decreases with increasing pre-damage levels by 40%.Design guideline ACI 440.2R (2004) predicts the ultimate load capacity marvelously for externally bonded Fiber-Reinforced Polymer (FRP) beams compared to the experimental maximum load capacity. The excellent agreement between experimental and FEM results indicates that the constitutive models used for concrete and reinforcement and the cohesive interface model can well capture fracture behavior. However, The FEM analysis predicts the beam to be slightly stiffer and more robust, probably because of the assumed perfect bond between concrete and reinforcement. The developed FEM can be used for further parametric study.