Gennadii Ivanovich Davydov

Gennadii Ivanovich Davydov

Auto-generated profile, based on publicly available information

Gennadii Ivanovich Davydov

V.P. Larionov Institute of the Physical-Technical Problems of the North SB RAS

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2023 in iPolytech Journal
Verified
Journal Article
Open access
PDF file
NMN. P. Mestnikov
N. P. Mestnikov
PVP. F. Vasilyev
P. F. Vasilyev
GDG. I. Davydov
G. I. Davydov
AKA. M. Khoyutanov
A. M. Khoyutanov
ААА. М.-Н. Альзаккар
А. М.-Н. Альзаккар
ALAlexander Lobashev
Alexander Lobashev
In this paper, effects of low and high ambient temperatures on the operation of a photoelectric unit are investigated. The research methodology consisted in determination of the energy efficiency of a photoelectric unit across a wide range of ambient temperatures, providing graphical interpretations and describing the procedure of field observations. Regularities in determining the average statistical indicators of energy efficiency rise and drop in a photoelectric unit were applied for a particular range of ambient temperatures. These studies were undertaken during the winter of 2021 in the Materials Science Laboratory of V.P. Larionov Institute of Physical-Technical Problems of the North, Siberian Branch of the Russian Academy of Sciences, using a fixed climate chamber. Reference parameters were obtained for changes in the photoelectric unit generating capacity (within -60ºC to +60ºC), which can be applied in modeling operational processes and engineering calculations of operating conditions of solar power plants. It was found that, at the same illumination and ambient temperature values, a photoelectric panel generates the maximum energy at -60ºC and minimal energy at +60 ºC, with the specific power drop for this temperature range being 19%. A significant drop in the specific power of the photoelectric unit was achieved at +30 ºC and higher due to the increased internal resistance of the unit. For temperatures below -40ºC, the specific power of the analyzed unit increased insignificantly due to the decreased internal resistance of the unit. The obtained values of the generating capacity of a photoelectric unit within a wide range of ambient temperatures can be used in developing a procedure for evaluating the effects of ambient temperature and its various ranges on the operation of photoelectric units, as well as for a more accurate determination of the solar generation energy potential under certain climate conditions. In future studies, field observations are planned to identify the nature of the effect of two and more climatic factors on the operation of a photoelectric unit.

1 March 2019
Verified
Conference Paper
Closed access
GDG.I. Davydov
G.I. Davydov
PVP.F. Vasilyev
P.F. Vasilyev
Object: Transport of electrical energy over long distances based on flexible power transmission systems using a thyristor voltage regulator. Methods: Transportation of electric power of an alternating current to ultra-long distances is possible by compensating or half-wave (tuned to half-wave) power transmission. Findings: In order to transmit electric power with alternating current to long-distance and ultra-long distances, half-wave power transmission should be preferred, since they do not require additional costs for reactive power compensation and, at the same time, have increased capacity. However, the advisability of tuning to a half-wave occurs when the line length is 1500 km or more. The line, which is less than 1500 km long, should be brought to the line of “zero length”. The reactance of the line, the length of which is less than the boundary length, that is, less than 1500 km, is proposed to be compensated and lead to a “zero” length line to increase throughput and stabilize the voltage regime along the line with the help of a thyristor parameter stabilizer developed at the Institute of Physical and Technical Problems of the North them. V.P. Larionov. Conclusions: A trunk line is proposed in the north, providing the centralized electricity supply to the new industrial centers of the northern and arctic regions of the Republic of Sakha (Yakutia). A new method for constructing extended power transmission in an understated voltage class based on high-current electronics was developed.

1 October 2018
Verified
Conference Paper
Closed access
AKA. M. Khoiutanov
A. M. Khoiutanov
GDG. I. Davydov
G. I. Davydov
The article deals with a half-wave transmission lines, which are the most prospective for transmit an electric energy over long distances. At the present time, their technical feasibility and economic efficiency are substantiated and it is proved that the half-wave transmissions can work as a transit ones. At the same time, the issue of a power take-off is unresolved yet. The main feature of a half-wave transmission line is the voltage changes in the middle part of the line from the maximum, in the load mode, to zero, in the idle. This prevents the traditional parallel power take-off in this part of the line. The studies of the operation regimes of a half-wave transmission lines with the power take-off were conducted using the model of a half-wave transmission line. As a result, it have been developed the methods and ways for power take-off from the line. It is shown that the usage of the thyristor parameter stabilizer makes possible the power take-off at any intermediate point of a half-wave transmission line.

5 April 2022 in iPolytech Journal
Verified
Journal Article
Open access
PDF file
NMN. P. Mestnikov
N. P. Mestnikov
PVP. F. Vasilyev
P. F. Vasilyev
GDG. I. Davydov
G. I. Davydov
AKA. M. Khoyutanov
A. M. Khoyutanov
ААА. М.-Н. Альзаккар
А. М.-Н. Альзаккар
This study investigates the effect produced by various types of cloudiness on the functioning of a photovoltaic system in the central part of the Republic of Sakha (Yakutia). The electric power efficiency of the photovoltaic system under various cloudiness conditions was assessed using graphical interpretations, measuring and recording devices, as well as a description of the procedure for conducting experimental work. The average indicators of a decrease in the electric power efficiency of the photovoltaic system were determined using patterns for a certain type of cloudiness. A specific cloudiness type was identified by performing measurements and calculating illumination ranges, taking boundary conditions into account. These studies were carried out during the summer period of 2021 using the facilities of the mobile test site of the V.P. Larionov Institute of the Physical-Technical Problems of the North of Siberian Branch of the Russian Academy of Sciences located in the central part of the Republic of Sakha (Yakutia). Control parameters of alterations in the generating capacity of the photovoltaic system were obtained for 10 types of cloudiness. The obtained parameters can be used when modeling operational processes and performing engineering calculations of the operating modes for solar power plants. According to the results, during the operation of photovoltaic systems under various types of cloudiness, the decrease in the generating capacity of the installation can vary within 8–95% relative to the generating capacity indicator under clear weather. The obtained indicators of alterations in the generating capacity of a photovoltaic system under various cloudiness conditions can be applied for developing a methodology for assessing the effect of cloudiness and its types on the carrying capacity of solar beams falling on the photovoltaic panel surface, as well as to more accurately determine the energy potential of solar generation in a certain area.

1 October 2019
Verified
Conference Paper
Closed access
GDG.I. Davydov
G.I. Davydov
AKA.M. Khoiutanov
A.M. Khoiutanov
VKV.P. Kobylin
V.P. Kobylin
Object: The method and means of buildinglong-distance power transmission with distributed low loads based on high-current electronics.Methods: Application of technology of Flexible Alternative Current Transmission System (FACTS) and active adaptive network technology (Smart grid).Findings: Analysis of possible methods of voltage regulation in power systems shows that the current control method should be referred to as the most effective for long-distance overhead lines. The implementation of this method is conducted by reactive power compensation devices, transformers with on-load tap changing, or voltage boosters. The latter allowssolving the problem of maintaining the voltage on long-distance overhead lines within acceptable limits, owing to the introduction of relatively small extra power with final control elements on thyristorkeys. There are two methods of excitation of boosting transformer. The first method is based on the change of the core saturation by DC magnetic biasing. The second is based on the traditional design of boosting transformer, which has power transformers in the excitation winding. This method suits narrow-range regulation. It implements the alternation of three modes depending on the load conditions: the voltage boost mode, zero additive mode, and negative boost mode. Avoltage regulator-restorer of the thyristor system developed at the Larionov Institute of Physical-Technical Problems of the North SB RAS is constructed on this principle.Conclusions: At present,FACTS are a very promising direction for the transmission and distribution of electric energy. With an increase in the share of renewable energy sources in a distributed generation system in conditions of long-distance power transmissions and a distributed low load, these systems will be able to expand the capabilities of existing electrical networks and become the basis for intelligent control systems and metering of electricity and power flows.

23 March 2018 in Interactive science
Verified
Journal Article
Open access
GDGennadii Ivanovich Davydov
Gennadii Ivanovich Davydov
AKAleksandr Mikhailovich Khoiutanov
Aleksandr Mikhailovich Khoiutanov
PVPavel Filippovich Vasilev
Pavel Filippovich Vasilev
VKVitalii Petrovich Kobylin
Vitalii Petrovich Kobylin
GSGerman Ivanovich Samorodov
German Ivanovich Samorodov
There are two different ways to transmit the AC electric power for a long distance: a compensated, the half-wave and tuned to half-wave transmissions. The compensation of the wave length is an effective way to increase the distance and the capacity of the transmission line. Through the wave length compensation it might to give to a long distance line the properties of the short line (except the active power losses). But with the distance and capacity increasing also increases a capacity of the compensation devices. Therefore, usage of the half wave and tuned to a half wave transmission lines to transmit an AC electric power for a long distances is more effective because there is no need to additional expenses to reactive power compensation by the stability conditions. The boundary length of the tuning to a half-wave is defined in article. The advisability of the tuning to a half-wave is arises when the length of the line more than 1500 km. Otherwise it recommended to tune the line to a «zero length».