13 March 2014 in Earth Surface Processes and Landforms
Two computational methods to measure particle rotations from shadow images of sand particles saltating in a wind tunnel are presented. One method calculates the maximum of the cross‐correlations through multiple angular rotations of an imaged particle. The second method polar transforms both images and then calculates the correlation coefficient for multiple pixel displacements in the θ axis, corresponding to particle rotations. The results from both methods were analysed as a function of height above sand bed (3.7–33.4 mm) and particle size (0.32–0.93 mm equivalent mean diameter). Our results indicate little evidence that particle rotation speeds depend on either their size or height above the sand bed. Though similar results were obtained from both methods, there existed different advantages and disadvantages between the methods. Erroneous results likely arose from particles that were inadequately described by a 2‐D rotation axis, or from poorly imaged particles. At a wind tunnel speed of about 12 m/s, most particles rotated at around 300–400 rev/s. Negative rotations were also found, and their proportion was approximately 15% within the total range of −450 to 850 rev/s. The ratio of displacement kinetic energy to rotation energy was compared across the various groups and had values between 15 and 40. The quotient showed little dependence on height, though decreased with increasing particle size. Wider applicability of the measurement methodology to study snow particle rotation is also discussed. Copyright © 2014 John Wiley & Sons, Ltd.
30 May 2021 in Fire Technology
1 June 2019 in IOP Conference Series: Earth and Environmental Science
Water mist extinguishing systems are becoming more popular due to their much higher fire-fighting efficiency at lower water consumption compared to conventional sprinklers. The article focuses on the possibility of further utilization in a form of cooling structures and presents the results of a research in the area of low-pressure water mist and the development of a new low-pressure water mist cooling system. It also introduces a new possible direction for application of cooling steel structures or their surroundings in order to increase fire resistance of steel structures. To verify the cooling effects of low-pressure water mist, a large-scale fire test with a model of steel roof construction was carried out in a room with dimensions of 4.0 × 4.0 × 2.0 m. The fire test was conducted in two scenarios. The first scenario is a reference test without application of water mist, where temperatures of the burning room and steel structures are monitored. Compared to the first scenario, the second scenario includes the use of low-pressure water mist protection of the steel structure model at the time of full fire development.