Alper Denasi

Alper Denasi

Auto-generated profile, based on publicly available information

Alper Denasi

Surgical Robotics Laboratory, Department of Biomedical Engineering, University of Groningen and University Medical Centre Groningen 3 , Groningen 9713 GZ, The Netherlands

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2019 in IEEE Sensors Journal
Verified
Journal Article
Closed access
FKFouzia Khan
Fouzia Khan
ADAlper Denasi
Alper Denasi
DBDavid Barrera
David Barrera
JMJavier Madrigal
Javier Madrigal
Salvador SalesSalvador Sales
Salvador Sales
SMSarthak Misra
Sarthak Misra

16 January 2019 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
JSJakub Sikorski
Jakub Sikorski
ADAlper Denasi
Alper Denasi
GBGiuseppe Bucchi
Giuseppe Bucchi
SSStefano Scheggi
Stefano Scheggi
SMSarthak Misra
Sarthak Misra
Automated steering of endovascular catheters has a potential of improving the outcome of minimally invasive surgical procedures. Nevertheless, actuation, tracking and closed-loop position control of catheters remain a challenge. In this study, we present a modular framework for 3D position control of magnetically-actuated endovascular catheter. The catheter is fitted with a permanent magnet and deflected using externally generated magnetic field provided by BigMag - an array of mobile electromagnets. Pseudo-rigid-body modelling is used to formulate an inverse-model closed-loop position controller of the catheter. The shape feedback is reconstructed from a 3D point cloud of catheter silhouette, obtained using stereo vision. Magnetic actuation is enabled using an inverse field map technique, mapping the reference magnetic field to BigMag configuration variables. The framework is tested in a series of experiments. The inverse map is validated, showing a mean magnetic field error of 2.20%. The accuracy of the shape reconstruction algorithm is 0.59 mm. Finally, the magnetically-actuated catheter is steered across a series of trajectories with maximum reported catheter deflection of 68.43° and maximum tip speed of 5 mm/s. Across all trajectories, the best control performance metrics are the mean error of 0.57 mm and the RMS error of 0.77 mm.

8 August 2017 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
ADAlper Denasi
Alper Denasi
SMSarthak Misra
Sarthak Misra
Microrobotics is a promising field that can revolutionize fields such as minimally invasive surgery. Applications such as micromanipulation can be performed more effectively using multiple microsized agents. These can be performed more accurately with the help of robust controllers. In this letter, we design a leader-follower controller that can be used to perform coordinated motion tasks. A prescribed performance controller is designed for the leader micro-agent whereas a synchronization controller is designed for the follower. The main difference between our method and the literature is that our method can achieve a prespecified control performance. The positions of the micro-agents are obtained using microscopic images and image processing. The velocities and accelerations of the micro-agents are obtained using state observers. The algorithm is tested experimentally on spherical magnetic microparticles that have an average diameter of 100 μm. Two types of experiments are performed. The first one is related to the leader-follower control, whereas the second one demonstrates the independent control of the two agents. The maximum value of the steady-state errors obtained in the leader-follower control experiments are 14.45 μm and 10.19 μm in the x-and y-directions for the leader agent and 6.47 μm and 7.77 μm in the x-and y-directions for the follower errors, respectively.

1 May 2019 in AIP Advances
Verified
Journal Article
Open access
PDF file
FOFederico Ongaro
Federico Ongaro
QJQianru Jin
Qianru Jin
UCUgo Siciliani de Cumis
Ugo Siciliani de Cumis
AGArijit Ghosh
Arijit Ghosh
ADAlper Denasi
Alper Denasi
SMSarthak Misra
Sarthak Misra
In recent years, untethered microdevices have drawn significant attention due to their small size, weight and their ability to exert forces without the need for wires or tethers. Such microdevices are relevant to implantable biomedical devices, miniature robotics, minimally invasive surgery, and microelectromechanical systems. While devices using these actuators have been widely utilized in pick-and-place and biopsy applications, the forces exerted by these actuators have yet to be characterized and analyzed. Lack of precise force measurements and validated models impedes the clinical applicability and safety of such thin film microsurgical devices. Furthermore, present-day design of thin film microdevices for targeted applications requires an iterative trial-and-error process. In order to address these issues, we present a novel technique to measure the force output of thin film microactuators. Also, we develop and fabricate three designs of residual stress microactuators and use them to validate this technique, and establish a relationship between performance and design parameters. In particular, we find an inverse dependence of the thickness of the actuator and its force output, with 70 nm, 115 nm and 200 nm actuators exerting 7.8 μN, 4.7 μN, and 2.7 μN, respectively. Besides these findings, we anticipate that this microsystem measurement approach could be used for force measurements on alternate microactuators including shape memory, piezo and electromagnetic actuators.

8 September 2016
Verified
Conference Paper
Open access
ADAlper Denasi
Alper Denasi
SMSarthak Misra
Sarthak Misra
Applications such as micromanipulation and minimally invasive surgery can be performed using micro-sized agents. For instance, drug-loaded magnetic micro-/nano- particles can enable targeted drug delivery. Their precise manipulation can be assured using a robust motion controller. In this paper, we design a closed-loop controller-observer pair for regulating the position of microagents. The prescribed performance technique is applied to control the microagents to follow desired motion trajectories. The position of the microagents are obtained using microscopic images and image processing. The velocities of the microagents are obtained using an iterative learning observer. The algorithm is tested experimentally on spherical magnetic microparticles that have an average diameter of 100 μm. The steady-state errors obtained by the algorithm are 20 μm. The errors converge to the steady-state in approximately 8 seconds.