14 March 2019 in IEEE Sensors Journal
16 January 2019 in IEEE/ASME Transactions on Mechatronics
Automated steering of endovascular catheters has a potential of improving the outcome of minimally invasive surgical procedures. Nevertheless, actuation, tracking and closed-loop position control of catheters remain a challenge. In this study, we present a modular framework for 3D position control of magnetically-actuated endovascular catheter. The catheter is fitted with a permanent magnet and deflected using externally generated magnetic field provided by BigMag - an array of mobile electromagnets. Pseudo-rigid-body modelling is used to formulate an inverse-model closed-loop position controller of the catheter. The shape feedback is reconstructed from a 3D point cloud of catheter silhouette, obtained using stereo vision. Magnetic actuation is enabled using an inverse field map technique, mapping the reference magnetic field to BigMag configuration variables. The framework is tested in a series of experiments. The inverse map is validated, showing a mean magnetic field error of 2.20%. The accuracy of the shape reconstruction algorithm is 0.59 mm. Finally, the magnetically-actuated catheter is steered across a series of trajectories with maximum reported catheter deflection of 68.43° and maximum tip speed of 5 mm/s. Across all trajectories, the best control performance metrics are the mean error of 0.57 mm and the RMS error of 0.77 mm.
8 August 2017 in IEEE Robotics and Automation Letters
Microrobotics is a promising field that can revolutionize fields such as minimally invasive surgery. Applications such as micromanipulation can be performed more effectively using multiple microsized agents. These can be performed more accurately with the help of robust controllers. In this letter, we design a leader-follower controller that can be used to perform coordinated motion tasks. A prescribed performance controller is designed for the leader micro-agent whereas a synchronization controller is designed for the follower. The main difference between our method and the literature is that our method can achieve a prespecified control performance. The positions of the micro-agents are obtained using microscopic images and image processing. The velocities and accelerations of the micro-agents are obtained using state observers. The algorithm is tested experimentally on spherical magnetic microparticles that have an average diameter of 100 μm. Two types of experiments are performed. The first one is related to the leader-follower control, whereas the second one demonstrates the independent control of the two agents. The maximum value of the steady-state errors obtained in the leader-follower control experiments are 14.45 μm and 10.19 μm in the x-and y-directions for the leader agent and 6.47 μm and 7.77 μm in the x-and y-directions for the follower errors, respectively.
1 May 2019 in AIP Advances
In recent years, untethered microdevices have drawn significant attention due to their small size, weight and their ability to exert forces without the need for wires or tethers. Such microdevices are relevant to implantable biomedical devices, miniature robotics, minimally invasive surgery, and microelectromechanical systems. While devices using these actuators have been widely utilized in pick-and-place and biopsy applications, the forces exerted by these actuators have yet to be characterized and analyzed. Lack of precise force measurements and validated models impedes the clinical applicability and safety of such thin film microsurgical devices. Furthermore, present-day design of thin film microdevices for targeted applications requires an iterative trial-and-error process. In order to address these issues, we present a novel technique to measure the force output of thin film microactuators. Also, we develop and fabricate three designs of residual stress microactuators and use them to validate this technique, and establish a relationship between performance and design parameters. In particular, we find an inverse dependence of the thickness of the actuator and its force output, with 70 nm, 115 nm and 200 nm actuators exerting 7.8 μN, 4.7 μN, and 2.7 μN, respectively. Besides these findings, we anticipate that this microsystem measurement approach could be used for force measurements on alternate microactuators including shape memory, piezo and electromagnetic actuators.