Zhengrong Zhu

Zhengrong Zhu

Auto-generated profile, based on publicly available information

Zhengrong Zhu

New Chemical Entity Molecular Discovery, GlaxoSmithKline, 200 Cambridgepark Drive, Cambridge, Massachusetts 02140, United States

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2017 in ACS Chemical Biology
Verified
Journal Article
Closed access
ZZZhengrong Zhu
Zhengrong Zhu
ASAlex Shaginian
Alex Shaginian
LGLaShadric C. Grady
LaShadric C. Grady
TOThomas O’keeffe
Thomas O’keeffe
XSXiangguo E. Shi
Xiangguo E. Shi
SPSandeep Pal
Sandeep Pal

19 February 2020 in Journal of Medicinal Chemistry
Verified
Journal Article
Closed access
WKWieslaw M. Kazmierski
Wieslaw M. Kazmierski
BXBing Xia
Bing Xia
JMJohn Miller
John Miller
MRMartha De la Rosa
Martha De la Rosa
DFDavid Favre
David Favre
VSVicente Samano
Vicente Samano

1 February 2019 in SLAS Discovery
Verified
Journal Article
Open access
PDF file
ZZZhengrong Zhu
Zhengrong Zhu
LGLaShadric C. Grady
LaShadric C. Grady
YDYun Ding
Yun Ding
KLKenneth E. Lind
Kenneth E. Lind
CDChristopher P. Davie
Christopher P. Davie
GEGhotas Evindar
Ghotas Evindar
DNA-encoded libraries (DELs) have been broadly applied to identify chemical probes for target validation and lead discovery. To date, the main application of the DEL platform has been the identification of reversible ligands using multiple rounds of affinity selection. Irreversible (covalent) inhibition offers a unique mechanism of action for drug discovery research. In this study, we report a developing method of identifying irreversible (covalent) ligands from DELs. The new method was validated by using 3C protease (3CP) and on-DNA irreversible tool compounds (rupintrivir derivatives) spiked into a library at the same concentration as individual members of that library. After affinity selections against 3CP, the irreversible tool compounds were specifically enriched compared with the library members. In addition, we compared two immobilization methods and concluded that microscale columns packed with the appropriate affinity resin gave higher tool compound recovery than magnetic beads.

27 October 2022 in Journal of Medicinal Chemistry
Verified
Journal Article
Closed access
XTXinrong Tian
Xinrong Tian
DSDominic Suarez
Dominic Suarez
DTDouglas Thomson
Douglas Thomson
WLWilliam Li
William Li
EKElizabeth A. King
Elizabeth A. King
BMBiju Mangatt
Biju Mangatt

1 June 2021 in Bioorganic & Medicinal Chemistry Letters
Verified
Journal Article
Closed access
JLJohn Liddle
John Liddle
APAndrew C. Pearce
Andrew C. Pearce
CAChristopher Arico-Muendel
Christopher Arico-Muendel
SBSvetlana Belyanskaya
Svetlana Belyanskaya
ABAndrew Brewster
Andrew Brewster
DLDavid A. Lomas
David A. Lomas

13 June 2003
Verified
Conference Paper
Closed access
PDF file
ZZZhengrong Zhu
Zhengrong Zhu
KLKevin Lucas
Kevin Lucas
JCJonathan L Cobb
Jonathan L Cobb
SHScott D Hector
Scott D Hector
ASAndrzej Strójwąs
Andrzej Strójwąs
EUV lithography at 13nm wavelengths will require the use of reflective multi-layer mask substrates with a patterned absorbing top layer. As the height of the absorber is many times the wavelength of the exposure radiation, EUV masks are true topographical entities. Therefore, scalar Frauenhofer diffraction simulations are not completely valid and accurate. Rigorous solution of Maxwell's equations in the topography is necessary to accurately predict many of the lithographic effects of these masks. Additionally, the interactions of the non-vertical radiation reflectance from the multilayer stack with the absorber causes further non-intuitive lithographic results which need to be understood and optimized. To further the rigorous understanding of EUV mask effects, we have extended existing 2D and 3D rigorous simulators to model EUV lithography diffraction. These simulators, METRO and METROPOLE-3D respectively, use the waveguide method for fast and accurate computation of topographical mask structures. Modifications of these simulators enable an order of magnitude speedup in the calculation of results containing large numbers of EUV multilayers, improve mask dimension modeling accuracy and enable accurate modeling of the non-normal EUV source illumination through a range of pitch values. Rigorous illumination and multilayer defect analysis results will also be shown. Additional comparisons to recently published rigorous EUV simulations results and impressive runtime results on standard desktop workstations are presented. The results show that for EUV lithography the best focus position and the symmetry of the aerial image intensity profile with respect to best focus is affected by the pattern pitch.