Michael J. MacCoss

Michael J. MacCoss

Auto-generated profile, based on publicly available information

Michael J. MacCoss

University of Washington

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2017 in Mass Spectrometry Reviews
Verified
Journal Article
Closed access
PDF file
LPLindsay K. Pino
Lindsay K. Pino
BSBrian Searle
Brian Searle
JBJames G. Bollinger
James G. Bollinger
BNBrook L. Nunn
Brook L. Nunn
BMBrendan MacLean
Brendan MacLean
MMMichael J. MacCoss
Michael J. MacCoss

3 December 2018 in Nature Communications
Verified
Journal Article
Open access
PDF file
BSBrian Searle
Brian Searle
LPLindsay K. Pino
Lindsay K. Pino
JEJarrett D. Egertson
Jarrett D. Egertson
YTYing S. Ting
Ying S. Ting
RLRobert T. Lawrence
Robert T. Lawrence
MMMichael J. MacCoss
Michael J. MacCoss
Data independent acquisition (DIA) mass spectrometry is a powerful technique that is improving the reproducibility and throughput of proteomics studies. Here, we introduce an experimental workflow that uses this technique to construct chromatogram libraries that capture fragment ion chromatographic peak shape and retention time for every detectable peptide in a proteomics experiment. These coordinates calibrate protein databases or spectrum libraries to a specific mass spectrometer and chromatography setup, facilitating DIA-only pipelines and the reuse of global resource libraries. We also present EncyclopeDIA, a software tool for generating and searching chromatogram libraries, and demonstrate the performance of our workflow by quantifying proteins in human and yeast cells. We find that by exploiting calibrated retention time and fragmentation specificity in chromatogram libraries, EncyclopeDIA can detect 20–25% more peptides from DIA experiments than with data dependent acquisition-based spectrum libraries alone.

1 May 2012 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
BSBirgit Schilling
Birgit Schilling
MRMatthew J. Rardin
Matthew J. Rardin
BMBrendan X. MacLean
Brendan X. MacLean
AZAnna M. Zawadzka
Anna M. Zawadzka
BFBarbara E. Frewen
Barbara E. Frewen
BGBradford W. Gibson
Bradford W. Gibson
Despite advances in metabolic and postmetabolic labeling methods for quantitative proteomics, there remains a need for improved label-free approaches. This need is particularly pressing for workflows that incorporate affinity enrichment at the peptide level, where isobaric chemical labels such as isobaric tags for relative and absolute quantitation and tandem mass tags may prove problematic or where stable isotope labeling with amino acids in cell culture labeling cannot be readily applied. Skyline is a freely available, open source software tool for quantitative data processing and proteomic analysis. We expanded the capabilities of Skyline to process ion intensity chromatograms of peptide analytes from full scan mass spectral data (MS1) acquired during HPLC MS/MS proteomic experiments. Moreover, unlike existing programs, Skyline MS1 filtering can be used with mass spectrometers from four major vendors, which allows results to be compared directly across laboratories. The new quantitative and graphical tools now available in Skyline specifically support interrogation of multiple acquisitions for MS1 filtering, including visual inspection of peak picking and both automated and manual integration, key features often lacking in existing software. In addition, Skyline MS1 filtering displays retention time indicators from underlying MS/MS data contained within the spectral library to ensure proper peak selection. The modular structure of Skyline also provides well defined, customizable data reports and thus allows users to directly connect to existing statistical programs for post hoc data analysis. To demonstrate the utility of the MS1 filtering approach, we have carried out experiments on several MS platforms and have specifically examined the performance of this method to quantify two important post-translational modifications: acetylation and phosphorylation, in peptide-centric affinity workflows of increasing complexity using mouse and human models.

1 July 2020 in Molecular & Cellular Proteomics
Verified
Journal Article
Open access
PDF file
LPLindsay K. Pino
Lindsay K. Pino
SJSeth C. Just
Seth C. Just
MMMichael J. MacCoss
Michael J. MacCoss
BSBrian Searle
Brian Searle
Data independent acquisition (DIA) is an attractive alternative to standard shotgun proteomics methods for quantitative experiments. However, most DIA methods require collecting exhaustive, sample-specific spectrum libraries with data dependent acquisition (DDA) to detect and quantify peptides. In addition to working with non-human samples, studies of splice junctions, sequence variants, or simply working with small sample yields can make developing DDA-based spectrum libraries impractical. Here we illustrate how to acquire, queue, and validate DIA data without spectrum libraries, and provide a workflow to efficiently generate DIA-only chromatogram libraries using gas-phase fractionation (GPF). We present best-practice methods for collecting DIA data using Orbitrap-based instruments, and develop an understanding for why DIA using an Orbitrap mass spectrometer should be approached differently than when using time-of-flight instruments. Finally, we discuss several methods for analyzing DIA data without libraries.

23 June 2013 in Nature Methods
Verified
Journal Article
Open access
PDF file
JEJarrett D Egertson
Jarrett D Egertson
AKAndreas Kuehn
Andreas Kuehn
GMGennifer E Merrihew
Gennifer E Merrihew
NBNicholas W Bateman
Nicholas W Bateman
BMBrendan X MacLean
Brendan X MacLean
MMMichael J MacCoss
Michael J MacCoss
A multiplexing strategy for data-independent acquisition (DIA)-based mass spectrometry addresses the limitation of low precursor selectivity to make DIA more practical for peptide analysis. In mass spectrometry–based proteomics, data-independent acquisition (DIA) strategies can acquire a single data set useful for both identification and quantification of detectable peptides in a complex mixture. However, DIA data are noisy owing to a typical five- to tenfold reduction in precursor selectivity compared to data obtained with data-dependent acquisition or selected reaction monitoring. We demonstrate a multiplexing strategy, MSX, for DIA analysis that increases precursor selectivity fivefold.

18 December 2023 in Nature
Verified
Journal Article
Open access
PDF file
STSusana Vázquez Torres
Susana Vázquez Torres
PLPhilip J. Y. Leung
Philip J. Y. Leung
PVPreetham Venkatesh
Preetham Venkatesh
ILIsaac D. Lutz
Isaac D. Lutz
FHFabian Hink
Fabian Hink
DBDavid Baker
David Baker
Many peptide hormones form an α-helix on binding their receptors1–4, and sensitive methods for their detection could contribute to better clinical management of disease5. De novo protein design can now generate binders with high affinity and specificity to structured proteins6,7. However, the design of interactions between proteins and short peptides with helical propensity is an unmet challenge. Here we describe parametric generation and deep learning-based methods for designing proteins to address this challenge. We show that by extending RFdiffusion8 to enable binder design to flexible targets, and to refining input structure models by successive noising and denoising (partial diffusion), picomolar-affinity binders can be generated to helical peptide targets by either refining designs generated with other methods, or completely de novo starting from random noise distributions without any subsequent experimental optimization. The RFdiffusion designs enable the enrichment and subsequent detection of parathyroid hormone and glucagon by mass spectrometry, and the construction of bioluminescence-based protein biosensors. The ability to design binders to conformationally variable targets, and to optimize by partial diffusion both natural and designed proteins, should be broadly useful.