Yi Liang

Yi Liang

Auto-generated profile, based on publicly available information

Yi Liang

State Key Laboratory of Organic Geochemistry, Guangdong Provincial Key Laboratory of Environmental Protection and Resources Utilization, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2022 in Water Research
Verified
Journal Article
Closed access
YLYi Liang
Yi Liang
XZXiangyu Zhou
Xiangyu Zhou
YWYiding Wu
Yiding Wu
YWYang Wu
Yang Wu
SGShutao Gao
Shutao Gao
ZYZhiqiang Yu
Zhiqiang Yu

22 February 2023 in Water Research
Verified
Journal Article
Closed access
YLYi Liang
Yi Liang
XZXiangyu Zhou
Xiangyu Zhou
YWYiding Wu
Yiding Wu
YWYang Wu
Yang Wu
XZXiangying Zeng
Xiangying Zeng
PPPing'AN Peng
Ping'AN Peng

12 December 2024 in Environmental Science & Technology
Verified
Journal Article
Closed access
YWYiding Wu
Yiding Wu
TYTianyue Yang
Tianyue Yang
YWYang Wu
Yang Wu
YLYi Liang
Yi Liang
XZXiangying Zeng
Xiangying Zeng
PPPing’aN Peng
Ping’aN Peng

22 April 2022 in Analytical Letters
Verified
Journal Article
Closed access
YWYang Wu
Yang Wu
BJBingjing Ji
Bingjing Ji
XZXiangying Zeng
Xiangying Zeng
YLYi Liang
Yi Liang
SGShutao Gao
Shutao Gao
ZYZhiqiang Yu
Zhiqiang Yu
Long-chain chlorinated paraffins (LCCPs) have gained attention due to their bioaccumulation and toxicity. However, their determination is hindered by low vapor pressure and limited elution from gas chromatography columns. In this study, ammonium acetate (CH3COONH4) was employed as the mobile phase additive and directly applied to high-performance liquid chromatography coupled with Orbitrap high resolution mass spectrometry (HPLC-Orbitrap HRMS). Acetate adducts [M + CH3COO]– were selected for quantifying the LCCPs. The mass spectral parameters, such as the radio frequency lens percentage, vaporizer, ion transfer tube temperature, and spray voltage, were optimized. A new analytical strategy for LCCPs was established based on HPLC-Orbitrap HRMS. The accuracy, limits of detection (LOD), and limits of quantification (LOQ) were equal to 94.8% to 109.4%, 7.9 to 16.0 pg/μL, and 26.3 to 53.3 pg/μL for the LCCPs, respectively. The linear range was between 0.04 and 10.0 ng/μL with R2 values of 0.999 for the LCCPs. The relative standard deviations for intra-day and inter-day precision were from 0.5% to 3.3% and from 0.7% to 7.2%, respectively. This method was validated using 20 sediment and soil samples. For the first time, highly chlorinated (Cl>15) and longer carbon chain length (C>36) homologues of LCCPs were observed in soil. The method was suitable for determining LCCPs while avoiding modified instruments and eliminating the incompatibility of CH2Cl2 with the HPLC mobile phase. Further measurements are required of sediment, soil, and air to better characterize LCCPs in the environment.

19 February 2023 in Journal of Chromatography A
Verified
Journal Article
Closed access
BTBoyang Tian
Boyang Tian
SGShutao Gao
Shutao Gao
ZZZhanjun Zhu
Zhanjun Zhu
XZXiangying Zeng
Xiangying Zeng
YLYi Liang
Yi Liang
PPPing'AN Peng
Ping'AN Peng

26 August 2024 in Environmental Pollution
Verified
Journal Article
Closed access
TYTianyue Yang
Tianyue Yang
XZXiangyu Zhou
Xiangyu Zhou
YWYiding Wu
Yiding Wu
YLYi Liang
Yi Liang
XZXiangying Zeng
Xiangying Zeng
ZYZhiqiang Yu
Zhiqiang Yu