Lyes Aksas

Lyes Aksas

Auto-generated profile, based on publicly available information

Lyes Aksas

IRIMAS, EA7499, Université de Haute-Alsace, Mulhouse, France

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2022 in Optical Engineering
Verified
Journal Article
Open access
PDF file
SSSumera Sattar
Sumera Sattar
PLPierre-Jean Lapray
Pierre-Jean Lapray
LALyes Aksas
Lyes Aksas
AFAlban Foulonneau
Alban Foulonneau
Laurent BiguéLaurent Bigué
Laurent Bigué
Conventional color image sensors, either charge-couple device or complementary metal oxide semiconductor, acquire images in three different channels, red, green, and blue (RGB). In colorimetry or spectrophotometry, these devices can have inaccuracy due to their low spectral resolution.1 Multispectral imaging (MSI) or hyperspectral imaging (HSI) aims at capturing images with more than three channels across the electromagnetic spectrum. These techniques can enhance the accuracy of the spectral and color estimation of a surface.2 The main difference between MSI and HSI is the number of sensing channels in a given spectral range. HSI typically has a higher spectral resolution but is an expensive technique that suffers from low spatial resolution, and it is mainly encountered in remote sensing applications.3 MSI is a trade-off4,5 that is more appropriate for a more extensive application board, such as medical imaging6 or quality inspection.7

9 May 2024 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Federico GrilliniFederico Grillini
Federico Grillini
LALyes Aksas
Lyes Aksas
PLPierre-Jean Lapray
Pierre-Jean Lapray
AFAlban Foulonneau
Alban Foulonneau
JTJean-Baptiste Thomas
Jean-Baptiste Thomas
Laurent BiguéLaurent Bigué
Laurent Bigué
We study the relationship between reflectance and the degree of linear polarization of radiation that bounces off the surface of an unvarnished oil painting. We design a VNIR-SWIR (400 nm to 2500 nm) polarimetric reflectance imaging spectroscopy setup that deploys unpolarized light and allows us to estimate the Stokes vector at the pixel level. We observe a strong negative correlation between the S0 component of the Stokes vector (which can be used to represent the reflectance) and the degree of linear polarization in the visible interval (average -0.81), while the correlation is weaker and varying in the infrared range (average -0.50 in the NIR range between 780 and 1500 nm, and average -0.87 in the SWIR range between 1500 and 2500 nm). By tackling the problem with multi-resolution image analysis, we observe a dependence of the correlation on the local complexity of the surface. Indeed, we observe a general trend that strengthens the negative correlation for the effect of artificial flattening provoked by low image resolutions.

18 March 2024
Verified
Book Chapter
Closed access
PDF file
ABAbou Bakary Ballo
Abou Bakary Ballo
MDMoustapha Diaby
Moustapha Diaby
DMDiarra Mamadou
Diarra Mamadou
ACAdama Coulibaly
Adama Coulibaly

20 May 2022
Verified
Conference Paper
Open access
LALyes Aksas
Lyes Aksas
PLPierre-Jean Lapray
Pierre-Jean Lapray
AFAlban Foulonneau
Alban Foulonneau
Laurent BiguéLaurent Bigué
Laurent Bigué
SPIE Digital Library Proceedings